Divi's Laboratories Ltd. Unit II Form 483, September 2017
FDA issued this Form 483 to Divi's Laboratories Ltd. Unit II in Visakhapatnam District, India (FEI 3004149463) at the end of a drug inspection that ended September 19, 2017. It lists 6 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Sep 26, 2017. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Sep 19, 2017
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Sep 26, 2017
- 7 days after the inspection
The 6 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Failure to assay final API batches
OBSERVATION 1 Your firm failed to test individual batches of final API for conformity with all appropriate specifications such as purity, strength, and identity prior to Specifically, your firm does not analyze for assay for all final API batches prior to. The following final API products were found to not be analyzed for assay: "Active Pharmaceutical Ingredient Number of final batches not analyzed for Assay prior to in2016 Number of final batches not analyzed for Assay prior to in2017 [illegible table rows]
- 2
Inadequate OOS investigations
OBSERVATION 2 Laboratory failures are not thoroughly investigated. Specifically, Out of Specification (OOS) investigations where laboratory error was not clearly identified were invalidated without adequate investigation into manufacturing, process, maintenance, and engineering activities. For example: (b) (4) (b) (4) a. Investigation No./ 2-PLV/OOS/IP-IM/W/012 for lot number [illegible] any other individual impurity out of specification ([illegible] % w/w, Spec of [illegible] % w/w), preliminary investigation did not identify laboratory error. Your preliminary laboratory investigation on February 20, 2017, interviewed that analyst on sample analysis, preparation of sample, environment and glassware and found no errors. Your March 03, 2017 extended preliminary laboratory investigation report, described data obtained from fresh preparation analysis is not comparable to initial analyzed data as the peak did not elute. Your further investigation report dated March 12, 2017, into the peak identified the peak as being [illegible] which also [illegible] manufactured at your site. Your gap analysis report shows your analyst stating he cleaned the balance area and weighing pan before performing weighing activity and taken precautions during sample transfer. However, you concluded that this was a cross contamination in your laboratory. Your investigation also shows that the same impurity has eluted in 17 other previous batches. Your documented manufacturing investigation only verified that there was no deviation being reported in the batch records and operations were followed. There was no thorough investigation into manufacturing, process, maintenance, and engineering activities and involved the relevant departments that may have attributed to batch contamination. Original results were invalidated without clear identification of laboratory error and adequate investigation into manufacturing, process, maintenance, and engineering. Original results were invalidated and batch was released using retest results. In addition, another OOS investigation (No./ 2-PL/I/OOS/IP-IM/W/010) initiated 5 days prior to this OOS for an impurity eluting at the same relative retention time was attributed to another cross contamination during sampling and original results invalidated. Within specification impurity at the same relative retention time has been quantified [illegible] times since the above OOS. b. Investigation No./ 2-PL/I/OOS/FF[illegible]/W/001 for lot number [illegible] any other individual impurity out of specification ([illegible] % w/w, specification [illegible] % w/w) your preliminary investigation report dated January 9, 2017, interviewed that analyst on sample analysis, preparation of sample, environment and glassware and found no errors. Reinjection and retest from HPLC bottle and bottle [illegible] analysis also showed that same impurity eluted in your sample at out of specification limits. The peak was identified by your laboratory as being [illegible] that is also manufactured at your site. Your extended investigation dated February 13, 2017, interview of your analyst performing activity as not performing any analysis before performing the [illegible]. You state that he performed secondary verification activities in ROI and LOD analysis and attributed the contamination coming from unhygienic hands due to lack of washing his hands after the secondary verification activity even though the analyst stated he performed the activity in clean and dedicated location, he has wiped his hands and did not observe any product on his hands. Batch resampling was authorized by QA on March 18, 2017 and passing resample was reported extended preliminary laboratory investigation report on April 12, 2017. Manufacturing investigation form was filled on June 2, 2017 after passing resample results and did not document adequate investigation into manufacturing, process development, maintenance, and engineering activities that may have attributed to
Shortened here; the PDF has the full text.
- 3
Analytical excursions not evaluated
OBSERVATION 3 Review of Analytical incident/excursion investigations as per your Atypical or out of trend results procedure (2-IRA/OP/03) showed instances in which samples injection sequence was completed but results were not calculated and/or compared to specification to ensure OOS results were not obtained and sample result screening is not occurring prior to invalidating the run for system suitability or chromatograph issues. For instance: a. On January 12, 2017, Incident 2-AT/FP[illegible]/W/002 was initiated after testing of 6 lots for theoretical plate count failure of peak in standard solution. Sample results were invalidated without evaluation of results to ensure OOS results were not obtained. b. On December 27, 2016, incident 2-AT/FF[V]/020 was initiated after testing of stability lot [illegible] (40C/75% RH, day 180) for baseline disturbance in sample preparation. System suitability was met and disturbance was attributed to air bubble in flow cell. Sequence was invalidated without evaluating and comparing of results to ensure OOS results were not obtained. c. On January 23, 2017, incident 2-AV/FP[illegible]/W/002 was initiated after testing of 6 lots for related compound and assay testing due to abnormal peak shape fronting at product peak in peak identification solution, sample solution and sample injections. System suitability was met. Peak was associated to mobile phase contamination or improper pH adjustment. Sequence was invalidated without evaluating and comparing of obtained results to ensure OOS results were not obtained.
- 4
No cleaning time/validation documentation
OBSERVATION 4 Your firm has failed to validate the manufacturing cleaning length of time from [illegible] to the [illegible] of production runs for manufacturing equipment to ensure your cleaning procedures are effective for the removal of the build-up of contaminants, degradants and microbes. The length in the chemical synthesis production area is to include equipment such as: reactors, [illegible]. Equipment in the pharma blocks include: [illegible]. There is no documentation to ensure your cleaning procedures are effective to remove microbial contaminants in the worst case locations of the different equipment after the [illegible] length of [illegible] or of continuous production. For example, the last continuous production in the Pharma block for [illegible] was from [illegible] to [illegible]; batches of [illegible] were processed through the [illegible] and [illegible] before a complete clean was conducted. [illegible] batches of [illegible] were processed in the [illegible] during this [illegible].
- 5
Inadequate cleaning instructions and records
OBSERVATION 5 Your firm does not have adequate cleaning instructions (Issue Control#5) for the major equipment in the Pharma block for [illegible]. Major equipment in the pharma blocks include: [illegible]. The batch cleaning record does not have detailed step by step instructions for how to clean the equipment, what parts to dismantle, supplies needed for cleaning, water temperature or pressure, and the volume of water needed for flushing the equipment.
- 6
Batch records not contemporaneously completed
OBSERVATION 6 Batch records are not always recorded contemporaneously at the completion of an operation. For example: On 9/12/2017 during the production of [illegible] batch the in-charge production employee had signed the "CHECKED BY" column at step [illegible] in the manufacturing record to increase the batch [illegible] to [illegible]. However the "DONE BY" column was not signed by the chemist and the operation was not completed. On 9/12/2017 during the production of [illegible] batch, batch record operation step [illegible] displays the initials of the chemist and the in-charge manager had signed the "CHECKED BY" and "DONE BY" column as completed. However the operation time "TO" and "DURATION" details are not completed for the operation; as well as the volumes of the [illegible].
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3004149463, newest first.
- Form 483, July 2024Inspection ended Jul 19, 2024 · Posted Oct 19, 2026VAI
- Form 483, December 2016Inspection ended Dec 6, 2016 · Posted Dec 28, 2016OAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.