Cerovene Inc.
612 Corporate Way Ste 10, Valley Cottage, New York, United States
FEI 3005890568DUNS 790387927
FDA has 9 inspections on file for Cerovene Inc. in Valley Cottage, New York (FEI 3005890568), from 2010 to 2026. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below. One of the four FOIA requests for this site has asked FDA for this inspection's 483.
FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing and analysis, through Dec 31, 2026. Its registrant is Cerovene, Inc. (D-U-N-S 790387927).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 9, 2010–2026
- 0 OAI · 4 VAI · 5 NAI
- Inspections with 483 observations shown
- 1 of 9
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 4 requests, latest May 18, 2026
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
9 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate equipment cleaning
OBSERVATION 1 (Repeat) Equipment and utensils are not cleaned, maintained at appropriate intervals to prevent malfunctions contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, During the inspection, we observed the following equipment cleaning deficiencies for equipment identified as having been cleaned: A. On 03/16/2026, we observed (b) (4) was being stored directly on the (b) (4) floor of (b) (4) while manufacturing (b) (4) Tablets USP (b) (4) Batch #(b) (4). The (b) (4) is utilized for unloading materials from (b) (4). B. On 03/16/2026, presence of white caked residue was observed in Capsule Machine ID #(b) (4) (Non-dedicated) product contact surfaces including cavities for encapsulation and Capsule (b) (4) ID #(b) (4). The equipment is located in Room #”* (Capsule Machine Room) and was cleaned for type «Planing (Major cleaning) on (b) (4) after manufacturing (b) (4) Capsules USP, (b) (4) Batch #(b) (4) on (b) (4), and the equipment was issued a “Cleaned” status. C. On 03/18/2026, presence of unknown white powder was observed inside the validation (b) (4) locations inside (b) (4) ID #(b) (4) located inside Room #** Block & (non-dedicated equipment). The equipment was last used for manufacturing (b) (4) and (b) (4) (b) (4) on (b) (4). A type “®“” cleaning (Major) was performed on (b) (4) (b) (4), and the equipment was issued a “Cleaned” status. D. On 03/18/2026, we observed the presence of white cake residue and buildup inside the (b) (4) Tablet Press Machine, ID #(b) (4) (non-dedicated equipment). The equipment was last utilized on (b) (4) to manufacture (b) (4) Tablets Batch #(b) (4). A type “?“” (Major) cleaning was performed on (b) (4) and the equipment was issued a “Cleaned” status.
- Observation 2
Inadequate computer system controls
OBSERVATION 2 (Repeat) Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, A. Per your VP of Operations, your firm does not review data, audit trails and alarm reports generated by the HMI ((b) (4)) of your non-dedicated (b) (4) Mixer (b) (4) ID# (b) (4). Operators that use this equipment have a shared ®® login and password “(b) (4)” for its operation and the date in the system was displayed as “01/10/25” and 15:09:34 on 03/18/2025 at 12:30pm. Per your Vice President Operations, alarms generated from the HMI are not backed up, printed, and automatically overwritten by the system after (b) (4). B. On 03/16/2026, we observed (b) (4) analytical balance ID #(b) (4) located in the Analytical Balance Room is not password-protected from changing the date and time by unauthorized users. Your QC Manager (b) (4) was able to change the date and time from the balance without log-in credentials. The analytical balance is utilized for weighing commercial drug product samples, chemical, and reagents for mobile phase preparation in the QC Lab for commercial drug products including (b) (4) Capsules, (b) (4) Tablets.
Show observation 3
- Observation 3
Expired/uncatalogued lab standards
OBSERVATION 3 Established lab control mechanisms are not followed. Specifically, During our lab walkthrough on 3/16/2026, we observed ®* volumetric flasks in the volumetric flask cabinet, containing expired stock standards for both impurities and the active compound, along with their corresponding working standards. This cabinet contained # stock standards, 8 intermediate standard diluent and P* working standards. Out of these ® flasks containing working standards, 7 flasks lacked a preparation date. I observed the following expired stock and working standards used for the testing of commercial drug products, in this cabinet: Product Type of Preparation | Expiry Date | Expiry after according to Brgparation (b) (4) Tmpuity Ju 25, Method Validation Tablets (b) (4), — od MVR (6) (4) Related (b) (4) § Substances 2018 95 Stock standard | January 30, (®)@) for assay 2026 Method Validation Tablets (©) @) Working standard for assay January 30, 2018 2026 10) (EE _Assay_ Stock standard January 16, dissolution 2026 (b) 4) Stock November (b) (4) tablets dissolution 20, 2025 Method Transfer MTR _(b) (4) | able standard (by@) 2024 36 Working dissolution standard Intermediate standard May 30, 2025 Method Validation MVR_Soap_Cleaning_201 Soap (Cleaning Validation) Working standard September 18, 2025 (b) (4) Intermediate No date (b) (4) Method Transfer API standard (b) (4) Impurity (b) (4) (b) (4) working (b) (4) content 2025 17 Impurity (b) (4) ‘working standard Impurity (b) 4) ‘working standard Impurity (b) (4) working standard Impurity (b) (4) (b) (4) ‘working standard Impurity (b) (4) (b) (4) ‘working standard
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Four requests to FDA under the Freedom of Information Act named this site, most recently on May 18, 2026. Each one asked for a Form 483.
Inspection ending Mar 23, 2026VAI
1 request. In the inspection history above. FDA has posted its Form 483.
- May 18, 2026FDA-FOIA-2026-5047Form 483· 1 of 5 sitesRecords released
Inspection ending Apr 28, 2025
3 requests. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on Oct 22, 2025. FDAgent holds no copy that FDA posted.
- May 5, 2026FDA-FOIA-2026-4430Form 483· 1 of 5 sitesWithdrawn
- Jun 18, 2025FDA-FOIA-2025-7828Form 483· 1 of 5 sitesRecords released
- May 16, 2025FDA-FOIA-2025-4498Form 483· 1 of 8 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, analysis
- Registration runs through
- Dec 31, 2026
- Registrant
- Cerovene, Inc.D-U-N-S 790387927
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3005890568 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3005890568. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.