GSK Vaccines GmbH Form 483, February 2026

FDA issued this Form 483 to GSK Vaccines GmbH in Marburg, Germany (FEI 3001314775) at the end of a biologics inspection that ended February 27, 2026. It lists 2 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Oct 26, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Feb 27, 2026
Biologics · Vaccines and Allergenic Products
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Oct 26, 2026
241 days after the inspection
Facility
FEI 3001314775
Marburg, Germany

The 2 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Unvalidated aluminum hydroxide cleaning procedures

    Your firm has not validated the cleaning procedures for dedicated equipment used in the manufacture of Aluminum Hydroxide adjuvant to prevent contamination or carry-over. This adjuvant is a component of your licensed U.S. products including (b)(4) Infanrix, Boostrix, Kinrix, and Pediarix. Specifically, your cleaning validation and monitoring program for the aluminum hydroxide adjuvant production suite ((b)(4) and (b)(4)) is inadequate. You have introduced unvalidated (b)(4) cleaning steps into routine production, failed to maintain a state of control for your validated (b)(4) cleaning process, and failed to adequately investigate recurring cleaning failures. a) You introduced an unvalidated (b)(4) workaround into your routine cleaning and manufacturing process. Since May 2023, you have used an unvalidated (b)(4) cleaning procedure with (b)(4) for all batches of Aluminum Hydroxide adjuvant. This procedure was implemented to mitigate a known design flaw where aluminum hydroxide (b)(4) (implemented May 2023) and is (implemented January 2026) and (b)(4) (b)(4) This (b)(4) cleaning step was not validated to demonstrate its effectiveness. Furthermore, this change to your cleaning process was not managed through your firm's change control system. b) Your cleaning verification monitoring program is inadequate in that you failed to complete verification for extended periods while continuing to manufacture and release commercial batches. Your firm's monitoring program [illegible]-118805-07 requires (b)(4) (b)(4) cleaning verification. These (b)(4) occurred because of invalid cleaning (b)(4) verification runs. The primary cause of these invalidated runs were (b)(4) Clean-In-Place (CIP) (also observed during routine production), an issue that (b)(4) during the (b)(4) stemmed directly from corrective actions your firm implemented to address the equipment design flaw referenced in observation 1a. You experienced (b)(4) where the process was not in a verified and controlled state: Following a valid verification run in (b)(4) the next successful (b)(4) verification was not completed until (b)(4). During this period, when the cleaning process was not in a verified state, at least (b)(4) batches of Aluminum Hydroxide adjuvant (b)(4) were manufactured and subsequently used in final (b)(4) and (b)(4) drug products released for distribution in the U.S. Following a valid verification run in the next (b)(4) (b)(4) successful (b)(4) verification was not completed until (b)(4). During this period, at least (b)(4) batches of Aluminum Hydroxide adjuvant (b)(4) were manufactured and subsequently used in final drug products released (b)(4) for distribution in (b)(4). c) Your firm failed to adequately investigate cleaning verification failures and implement timely and effective corrective actions. Of the eleven invalid cleaning verification runs between January 2024 and October 2025, eight were not documented as deviations to investigate failures, as required by your procedure (b)(4) SOP 014 "Deviation Handling" ((b)(4)-SOP-082366). These undocumented failures include at least six instances of recurring CIP system malfunctions during the (b)(4) step related to (b)(4) (b)(4) in (b)(4) which prevented the achievement of required (b)(4). These failures occurred in: Run (b)(4) (April 2024), Run (b)(4) (May 2024), Run (b)(4) (June 2024), Run (b)(4) (September 2024), Run (b)(4) (March-April 2025), Run (b)(4) (July 2025).

  2. 2

    Failure to investigate unexplained test discrepancies

    There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has [illegible]. Specifically, the firm failed to conduct formal investigations, in accordance with SOP-082366, "Deviation Handling," for failed test results associated with the Aluminum Hydroxide (b)(4) Adjuvant filling equipment. SOP 9000087625, "Requirements for (b)(4)" states that a quality deviation is not required to be initiated unless (b)(4) (b)(4) test failures occur. Although each test failure is reviewed (b)(4) (b)(4) by Quality Assurance and documented in the Aluminum Hydroxide Adjuvant batch record, a formal investigation is not required for (b)(4) failures of this validated (b)(4) test performed using the [illegible]. A retrospective review identified a pattern of (b)(4) (b)(4) across (b)(4) consecutive batches manufactured in 2024 and periodic failures afterwards. The lack of documented investigations for the (b)(4) test failure(s) results in insufficient data for effectiveness verification, or trending of recurring (b)(4) test failures. Deviation 201088144 was generated on 09/18/2024 after two test failures. The (b)(4) tests for the aluminum hydroxide (b)(4) was (b)(4) (b)(4) by the [illegible] with the result which is classified as invalid. After (b)(4) (b)(4) using (b)(4) of the other (b)(4) possible (b)(4) according to defined procedure, the (b)(4) test passed prior to filling for batch # (b)(4) (b)(4). However, there was no justification for the aborted tests. CAPA 201097467 was initiated on 03/05/2026 and the effectiveness check is currently in progress.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3001314775, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.