Shanghai Henlius Biopharmaceutical Co., Ltd.

China

FEI 3016529861DUNS 544358442

FDA has 2 inspections on file for Shanghai Henlius Biopharmaceutical Co., Ltd. in China (FEI 3016529861), from 2023 to 2026. The latest ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its 11 observations from the PDF; they are listed below. One of the two FOIA requests for this site has asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, API manufacturing, packing, labeling and analysis, through Dec 31, 2026. Its registrant is Shanghai Henlius Biopharmaceutical Co., Ltd. (D-U-N-S 544358442).

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
2, 2023–2026
0 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
1 of 2
Form 483s posted by FDA
↗
Requested under FOIA
2 requests, latest Jul 15, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. Not classified yetClassification not posted yetPosted 483 · 11 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      PPQ failed to demonstrate controlled consistent process

      Your firm failed to demonstrate that the manufacturing process remained in a state of control and was capable of consistently producing drug product meeting established quality attributes during process performance qualification (PPQ) for (b)(4) mg/(b)(4) mL presentation. Specifically, your firm manufactured three PPQ batches [illegible] of (b)(4) mg/(b)(4) mL presentation. These batches exhibited increasingly high overall rejection rates at [illegible]% , [illegible]% and [illegible]% respectively during 100% (b)(4) visual inspection. The rejection rates for major defects were (b)(4)%, [illegible]% and (b)(4)% for the three batches mainly due to visible particulates. The rejection rates for batches (b)(4) exceeded your pre-defined (b)(4)% acceptance criterion for major visual inspection defects. These results indicate that the PPQ batches did not adequately demonstrate process consistency, reproducibility, and continued control with respect to visible particulate defects.

    2. Observation 2

      Inadequate investigation of particulate rejection rates

      Your firm failed to adequately investigate the progressively increasing high visible particulate rejection rates identified during 100% visual inspection of the (b)(4) mg/(b)(4) mL PPQ batches. Specifically, to investigate the two (b)(4) mg/(b)(4) mL PPQ DP batches (b)(4) that exhibited visible particulate rejection rates exceeding the predefined visual inspection acceptance criterion of (b)(4)%, (b)(4) units from each batch's rejected unit pool of major defect were randomly selected for further identification. This represented (b)(4)% and (b)(4)% sampling from the major defect pools of the two PPQ batches respectively. The sampling of the studies had no documented justification to ensure that the sampled units were representative or scientifically appropriate. The investigation did not provide adequate scientific justification to support that current manufacturing operation is a controlled process. The high and variable visible particulate defects indicate a recurring manufacturing or contamination control issue. The investigation was inconclusive in determining the root cause of the high visible particulate defects in these batches.

    Show observations 3 to 11
    1. Observation 3

      Inadequate oversight of visual inspection criterion change

      Your firm failed to maintain adequate quality oversight over changes to the established acceptance criterion for 100% visual inspection. Specifically, your firm retrospectively revised the visual inspection acceptance criterion to (b)(4)% from (b)(4)% as defined in the (b)(4) mg/(b)(4) mL PPQ protocol (PV-VP-000027), and the revision of visual inspection acceptance criterion was implemented retrospectively without an approved change control. Your firm did not adequately evaluate the potential impact of the revised criterion on product quality, batch disposition, process control, or the validity of the original acceptance criterion.

    2. Observation 4

      Inadequate cleaning validation for manufacturing equipment

      Your firm's cleaning validation programs for manufacturing equipment and components are inadequate in demonstrating that equipment used in drug substance and drug product manufacturing can be consistently cleaned to prevent contamination or carryover. Specifically, a. Your firm's (b)(4) cleaning validation for (b)(4) and (b)(4) used in the manufacture of (b)(4) drug substance did not include swab sampling or visual inspection of the internal product-contact surfaces of the (b)(4). Your cleaning validation sampling plan did not provide adequate scientific justification demonstrating that rinse samples were representative of the most difficult to clean locations within the (b)(4). b. Your firm did not perform cleaning validation for indirect product contact equipment used on the filling line. Your cleaning verification studies of indirect product contact filling line equipment did not include testing or scientifically justified acceptance criteria for removal of (b)(4) residues from relevant filling line components, including stopper handling and transferring equipment where (b)(4) carryover may occur.

    3. Observation 5

      Operator failed to follow filling procedure settings

      During the filling of (b)(4) drug product, (b)(4) mg/(b)(4) mL, (b)(4) mL vial on May 13, 2026, an operator failed to set the (b)(4) settings of (b)(4) as indicated in step (b)(4) of Standard Operating Procedure SOP-00273 (version 14, effective date: April 16, 2026). As a result, the (b)(4) for (b)(4) mL vials as referenced in section (b)(4) of the (b)(4) were observed at (b)(4) respectively, contrary to the corresponding (b)(4) settings of (b)(4) at (b)(4). (b)(4) were not performed during any time of the operation. No written procedure is established on recording the (b)(4) setting of (b)(4). Additionally, the cover of the (b)(4) was cracked and was held together with transparent tape during operation.

    4. Observation 6

      Inadequate QC laboratory test sample controls

      Your quality control laboratory procedures and controls for test and sample management are inadequate or not followed. Specifically, a. Permission assigned to analysts in Empower chromatography software includes the privilege to view quantitation peak fields in review. This allows analysts to view area accounts and results at the time of integration. QC analysts were observed changing the integration parameters without saving interim results. There is no documented justification why the initially applied integration parameters were not suitable before changing the integration parameters. b. SOP-01655 and test record of size exclusion chromatography (SEC) of aggregates (b)(4) method do not specify how to verify the storage duration for the prepared samples stored in the (b)(4). The (b)(4) aggregates of (b)(4) are sensitive to change of (b)(4). A prolonged (b)(4) of the sample may cause (b)(4) degradation and method variability. SOP-01655 is developed to control (b)(4) of (b)(4). Per SOP-01655, the prepared sample is allowed to be stored in (b)(4) up to (b)(4). c. Your QC sample management procedure is not adequate for sample reconciliation of the electronic system. Specifically, on May 12, 2026, Laboratory Information Management System (LIMS) showed that a total of (b)(4) samples were historically located in the 2-8 C refrigerator (QC-C-637) in QC physical chemical lab room (b)(4). Analysts discard QC samples periodically by filling out the "Record for Discarding Remaining Test Samples (Form-00021)". QC samples were not reconciled in LIMS after disposal on April 30, 2026 and May 11, 2026.

    5. Observation 7

      No controls preventing unauthorized data deletion

      Your firm failed to establish adequate controls to prevent unauthorized deletion of electronic laboratory data during data archiving process. Specifically, the deletion protection setting for (b)(4) analyzer (b)(4) was removed when IT was archiving electronic data from (b)(4) to (b)(4). During audit on May 12, 2026, an operator demonstrated unauthorized deletion of data files (i.e., (b)(4)) from (b)(4) analyzer (b)(4) during data archiving.

    6. Observation 8

      Uncontrolled refrigerator in DS clean area

      Your firm failed to adequately control non-process equipment located in drug substance manufacturing clean areas. Specifically, a (b)(4) refrigerator is located in Building (b)(4) Room (b)(4) where drug substance formulation, (b)(4) operations are performed. Your firm did not define the intended use or storage controls of the refrigerator, had no written procedure for routine cleaning and disinfection of the refrigerator, and did not perform risk assessment to justify its presence in the clean room or evaluated its potential contamination risk to processing operations.

    7. Observation 9

      Inadequate control of temperature monitoring sensors

      Your firm failed to maintain adequate control and traceability of temperature monitoring sensors within the building management system. Specifically, during walkthrough inspection of Building/Equipment Management System (BMS/EMS) located in Building (b)(4) room (b)(4) on May 11, 2026, an alarm record at 13:03:25 on May 8, 2026 associated with sensor TT4038_2 for equipment QC-C-430 refrigerator could not be retrieved when a query was sent to the audit trail system. The firm stated that the sensor TT4038_2 displayed in the audit trail of the (b)(4) product storage Equipment Parameter Monitoring System (ENG-E-140) did not match the actual sensor position. The firm admitted that during the configuration process after equipment location change (Change Control: PR44994), the engineer omitted the "Source" item tag in the audit trail and failed to update the tag from sensor TT4038_2 to sensor TT4039_1.

    8. Observation 10

      Inadequate contamination control in classified areas

      Procedures and practices intended to prevent contamination and maintain appropriate conditions within classified manufacturing areas are inadequate. Specifically, a. On May 17, 2026, an open biohazardous waste bag containing (b)(4) waste material was observed lying directly on the floor in Grade C manufacturing Room (b)(4) while a (b)(4) operation was in progress. Waste material was observed protruding from the open bag and exposed to the room environment. Room (b)(4) is used for drug substance formulation, (b)(4). No bag rack, holder, or other container was used to secure the biohazardous waste bag and prevent exposure of the waste material to the classified manufacturing environment. b. On May 17, 2026, while observing (b)(4) operation in Building (b)(4) Grade C Room (b)(4), a (b)(4) waste container containing waste (b)(4) was observed being placed on the lower shelf of a (b)(4) table which is not designated as a waste storage location.

    9. Observation 11

      Untimely investigation of sample handling error

      Your firm failed to investigate a laboratory sample handling error in a timely manner. Specifically, on May 4, 2026, batch record (b)(4) recorded that an operator used a wrong sample to perform (b)(4) testing at Step (b)(4) of the (b)(4) production bioreactor operation for (b)(4) drug substance batch (b)(4) and generated result (b)(4) which was not related to batch (b)(4) but saved with the actual IPC test results (b)(4). No deviation was initiated until May 14, 2026 after inquired by inspector.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on Jul 15, 2026.

  • Inspection ending May 20, 2026Not classified yet

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Jul 15, 2026FDA-FOIA-2026-6726Form 483· 1 of 2 sitesRecords released
  • Inspection date not given

    1 request. None of FDA’s log entries for these requests say records were released.

    1. Sep 12, 2025FDA-FOIA-2025-10876Inspection recordsClosed, no reply from requester

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, API manufacturing, packing, labeling, analysis
Registration runs through
Dec 31, 2026
Registrant
Shanghai Henlius Biopharmaceutical Co., Ltd.D-U-N-S 544358442

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3016529861 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3016529861. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.