Skip to content

GenIbet Biopharmaceuticals, S.A.

Avenida Da Republica, Edificio Da Unidade Piloto Do Ibet,, Oeiras, Portugal

FEI 3011160795DUNS 509806647

FDA has 2 inspections on file for GenIbet Biopharmaceuticals, S.A. in Oeiras, Portugal (FEI 3011160795), from 2023 to 2025. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 2 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Two of the three FOIA requests for this site have asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2026. Its registrant is GenIbet Biopharmaceuticals (D-U-N-S 509806647).

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
2, 2023–2025
0 OAI · 2 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
Form 483s posted by FDA
↗
Requested under FOIA
3 requests, latest Sep 10, 2025
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Vaccines and Allergenic Products2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Items to cover on annual reviews

      Written procedures are not established for evaluations done at least annually and including provisions for a review of investigations conducted for each drug product.

    2. Maintenance of Complaint File

      Complaint procedures are deficient in that written complaint records are not maintained in a file designated for drug product complaints.

  2. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Vaccines and Allergenic ProductsPosted 483 · 4 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      No written production and process controls

      There are no written procedures for production and process controls designed to assure that the [illegible] have (b)(4) the identity, strength, quality, and purity they purport or are represented to possess. Specifically, there is insufficient data to support the maximum target batch size, hold time, and process control parameters for the manufacture of (b)(4). [illegible] executed batch sizes for the process performance qualification a. The (b)(4) do not represent the maximum target batch size of [illegible] as [illegible] per the current approved master batch record, (b)(4). b. There is insufficient data to ensure that the uniformity of the formulated (b)(4) containing (b)(4) [illegible] is maintained throughout the hold time and during the [illegible] within the (b)(4). (b)(4) c. The operating ranges specified during manufacturing are not optimized. For example, an (b)(4) [illegible] specification for (b)(4) stages are not specified in the manufacturing batch record. Current operating ranges for (b)(4) respectively. (b)(4) detection device to ensure that the d. There is no (b)(4) is free of contamination. e. The supplier for (b)(4) respectively), used allows the [illegible] for the (b)(4) steps during the manufacturing of [illegible]. A toxicological assessment was not performed to evaluate the safety of the presence of particles which are not particulate-free. [illegible] while using the (b)(4). f. There are no equipment logs for the (b)(4) and the usage and cleaning history of these pieces of equipment are not readily available.

    2. Observation 2

      Inadequate equipment cleaning validation

      Equipment cleaning processes are inadequate. Specifically: a. The cleaning validation study (Cleaning Validation Summary Report) performed on (b)(4) contact equipment does not ensure removal of the [illegible]. Specifically: i. (b)(4) was not performed to ensure that the product is removed from the difficult to clean areas. (b)(4) was not assessed. ii. (b)(4) iii. The cleaning validation did not include the maximum lot size of (b)(4). b. [illegible] hold time is not representative of the manufacturing process, which includes (b)(4) (b)(4) that equipment are exposed to the Grade [illegible] environment after cleaning (b)(4). c. [illegible] hold time is not representative of the manufacturing process, which includes a hold [illegible] (b)(4) decontamination. manufacturing [illegible].

    Show observations 3 to 4
    1. Observation 3

      Incomplete decontamination cross-contamination prevention

      Decontamination is incomplete or not adequately demonstrated to ensure prevention of cross-contamination. Specifically: a. A decontamination study was not performed to evaluate the effectiveness of [illegible] which is used to (b)(4) decontaminate [illegible] parts, against (b)(4). b. (b)(4), Report on the Cleaning Validation Strategy and Results did not evaluate the material of construction of all equipment or materials including (b)(4) (b)(4) (b)(4) [illegible] and a risk assessment was not performed to justify not evaluating these materials of construction, which includes equipment or materials.

    2. Observation 4

      Deficient equipment cleaning maintenance procedures

      Written procedures for decontamination, cleaning, and maintenance of equipment are deficient regarding sufficient details to protect equipment from contamination prior to use. For example: a. (b)(4) (b)(4) do not specify the duration that equipment may be exposed to the environment after cleaning (b)(4). b. (b)(4), Cleaning Validation Summary Report, does not specify how the hold time is determined. c. Protocols governing decontamination of containing equipment that [illegible] the manufacturing suites are [illegible] locations in order to prevent contamination. [illegible] deficient regarding sufficient details such as the [illegible].

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Three requests to FDA under the Freedom of Information Act named this site, most recently on Sep 10, 2025. Each one asked for a Form 483.

  • Inspection ending Jan 21, 2025VAI

    2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Feb 26, 2026. FDAgent holds no copy that FDA posted.

    1. Sep 10, 2025FDA-FOIA-2025-10827Form 483Records released
    2. Jun 8, 2025FDA-FOIA-2025-7328Form 483Records released
  • Inspection ending Jan 31, 2023VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Jul 8, 2025FDA-FOIA-2025-8360Form 483· 1 of 3 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 2 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 2 inspections.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing
Registration runs through
Dec 31, 2026
Registrant
GenIbet BiopharmaceuticalsD-U-N-S 509806647

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3011160795 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3011160795. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.