FDA issued this Form 483 to Bioiberica, S.A.U in Palafolls, Spain (FEI 1000418405) at the end of a drug inspection that ended February 4, 2022. It lists 5 observations. FDA classified the inspection Official Action Indicated (OAI) and issued the facility a warning letter on June 30, 2022.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jun 9, 2022. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Feb 4, 2022
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Jun 9, 2022
125 days after the inspection
Facility
FEI 1000418405
Palafolls, Spain

The 5 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Inadequate cleaning and contamination control

    Cleaning procedures for equipment used in the campaign manufacture facilitated adequate cleaning and contamination prevention measures. Specifically, current cleaning operations at your firm [illegible] equipment (b)(4) with water and (b)(4) with dry clean equipment is used for campaign production on successive [illegible] adequately validated to be cleaned at appropriate intervals to prevent build-up [illegible] degradants or objectionable levels of microorganisms. Furthermore, during the current inspection, I reviewed [illegible] conformities were initiated for microbial contamination [illegible] your firm "reprocessing" the batch. In addition, I reviewed substance which was determined to be a result of (b)(4) buildup blocking the (b)(4) used [illegible]. I reviewed customer complaints for (b)(4) or "dark particles" observed [illegible] drum which were investigated by your firm and found [illegible] process in the [illegible] equipment.

  2. 2

    Missing process control and impurity profiling

    Control procedures are not established which monitor the manufacturing processes that may be responsible for [illegible] substance. Critical process parameter established as [illegible] the your firm is not controlled and monitored during the process validation studies. [illegible] the [illegible] validate and approve processing method [illegible] greater than (b)(4) with validated time around [illegible]. No studies have been performed on the effect of the [illegible] degradant control in the (b)(4) USP drug substance which considers the validated procedure during normal manufacturing operations using the (b)(4). Furthermore, from the years 2020-2021, I observed at least 23 batches which [illegible] operation, and up to five (b)(4) operations, with no documented justification [illegible] additional (b)(4). In addition, your firm has not performed an impurity profile to study the identified and unidentified impurities which may be present in your (b)(4) USP drug substance and consequently does [illegible] released drug substance. As a result, the validity of [illegible].

  3. 3

    QC unit deficiencies in assay and investigations

    The quality control unit lacks responsibility to approve all procedures which assure strength, quality, and purity of drug substances. Specifically, A. During my review of electronic HPLC data for assay testing, [illegible] encountered during analysis of drug substance, samples are re-tested until desirable results are achieved. Original test results were not reported, and no laboratory investigation procedure. Specifically during review of your firm's [illegible], (b)(4) or (b)(4) SP was analyzed in support [illegible] two active ingredients [illegible] and in your firm encountered unknown peaks for [illegible]. No investigation was performed. Instead, your firm prepared new [illegible] reported results as within specification. B. Your assay test method calls for preparing an internal standard from [illegible] to determine system suitability. During my review of electronic data [illegible] multiple occasions where the sample solution was tested more than [illegible] system suitability specifications. In response, your firm discarded standard preparations and prepared a new sample solution along with a new internal standard solution for testing. Per your firm, a new sample solution is prepared since a new internal standard is also prepared, for both preparations to have (b)(4) concurrently for testing. In your laboratory assay method validation, it was determined [illegible] stable [illegible] there is no scientific justification for preparing new sample solutions for re-testing. C. The assay test method used to identify two active ingredients [illegible] adequately verified by your QC laboratory. Your firm contracted a testing laboratory to perform validation for your assay test method. Upon receiving this report [illegible] for accuracy. No consideration was given to performing a study which incorporated reproducibility, repeatability, precision, analytical range, limit of quantification (LOQ) and Limit [illegible]. D. In addition, your firm has not performed an impurity [illegible] unidentified impurities which may be present in your [illegible] perform impurity testing for released drug substance.

  4. 4

    No stability-indicating testing program

    There is no written testing program designed to assess the stability characteristics [illegible]. Specifically, the assay test method for active ingredients [illegible] substance is not stability indicative (b)(4) [illegible] it can detect the change with [illegible]. Microbiological properties of the (b)(4) USP drug substance are specific so that the content and degradation products can be accurately measured without interference. As a result, the validity of the process cannot be verified, in that your [illegible] assure safety, efficacy and quality for your (b)(4) USP finished drug substance.

  5. 5

    Insufficient investigation records and follow-up

    Written records of investigations into unexplained discrepancies do not always include conclusions and follow-up which are adequately justified. Specifically, A. Investigations initiated and performed as a result [illegible] substance do not extend to batches manufactured during the campaign. B. During the inspection, I reviewed non-conformity investigations due to (b)(4) being blocked due to (b)(4) particle build. Your [illegible] which the (b)(4) was changed (b)(4). No consideration was given to cleaning operation impact on [illegible] (b)(4) during the investigation and CAPA process.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.