Equipment cleaning and cleaning validation in FDA Form 483 observations
Cleaning procedures for manufacturing equipment, the studies that show they work, and the residues, swabs and logs that prove each cleaning. FDAgent finds 197 such observations in 144 Form 483s issued to 138 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 197
- Each quoted below
- Form 483s
- 144
- Posted by FDA
- Facilities
- 138
- Distinct FEIs
- Most recent
- Sep 28, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 63 in 2026
| Year | Observations |
|---|---|
| 2008 | 1 |
| 2009 | 0 |
| 2010 | 0 |
| 2011 | 0 |
| 2012 | 0 |
| 2013 | 0 |
| 2014 | 1 |
| 2015 | 1 |
| 2016 | 10 |
| 2017 | 15 |
| 2018 | 20 |
| 2019 | 5 |
| 2020 | 5 |
| 2021 | 10 |
| 2022 | 7 |
| 2023 | 22 |
| 2024 | 13 |
| 2025 | 24 |
| 2026 | 63 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
The same entries the equipment cleaning topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“cleaning validat*” · “validat* … cleaning” · “cleaning procedure*” · “cleaning process*” · “cleaning record*” · “cleaning log*” · “cleaning agent*” · “cleaning verification” · “cleaning stud*” · “cleaning method*” · “cleaning effectiveness” · “not cleaned” · “not adequately cleaned” · “not properly cleaned” · “residue*” · “swab*” · “carry over” · “carryover”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 197 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Ranier’s Compounding LaboratoryInspection ended May 22, 2018 · FEI 3012124170 · Observation 6
… Between the general pharmacy and the gowning room, and between the gowning room and the Prep room, are plastic curtains that are not cleaned. Before production of Tobramycin 14 mg/mL Ophthalmic solution lot 151618-2CR for Rx (b)(6) the pharmacist checking the formula worksheets and components was observed without gowning walking from the unclassified general pharmacy through the gowning room (ISO 8) before entering the Prep room to perform the …
Contains “not cleaned”Read the Form 483 →
Ranier’s Compounding LaboratoryInspection ended May 22, 2018 · FEI 3012124170 · Observation 7
Non-microbial contamination was observed in your production area. Specifically, white residue was observed on the face panel of the HEPA filter supplying air to the ISO 5 area. In addition, the floor of the ISO 7 clean room has visible dirt, stains, or residue that are not removed during routine cleaning.
Contains “residue*”Read the Form 483 →
Ranier’s Compounding LaboratoryInspection ended May 22, 2018 · FEI 3012124170 · Observation 9
The ISO 5 classified aseptic processing areas and segregated production areas surrounding the ISO 5 classified aseptic processing area contained dust-collecting overhangs without adequate and frequent cleaning. Specifically, there are horizontal, flat surfaces above the ISO 5 hood. Those are not cleaned during routine cleaning, and the hired (b)(4) cleaning services do not include the ISO 5 hood. In addition, there are other such surfaces in the …
Contains “not cleaned”Read the Form 483 →
Galaxy Surfactants Ltd.Inspection ended Mar 30, 2018 · FEI 3004879807 · Observation 5
5. Your firm failed to establish an appropriate equipment cleaning procedure to assure an adequate cleaning of equipment and its subsequent release for use in the manufacture of intermediates and APIs. Specifically, Your SOP # PR003-01 (Effective date 2/23/2018) does not specify the maximum time that elapse between the completion of processing and equipment cleaning, when appropriate. In addition, your procedure does not include equipment clean …
Contains “cleaning procedure*”Read the Form 483 →
Galaxy Surfactants Ltd.Inspection ended Mar 23, 2018 · FEI 3010166890 · Observation 2
2. Your firm failed to validate the analytical methods required for the trace analysis of API residue as part of the cleaning validation program. Specifically, there is not validation report that confirms the sensitivity of <USP621> analytical method to detect the established acceptable level of the residue or contaminants. The method's attainable recovery level is also not established.
Contains “residue*”Read the Form 483 →
Plasma Industries Belgium SCRLInspection ended Mar 16, 2018 · FEI 3003208230 · Observation 1
The CIP cleaning validation of Vessel documented under Document (b)(4) entitled "CIP for vessel (b)(4) on (b)(4) did not include a justification for not [illegible] (b)(4) an area of the vessel (vessel (b)(4) that is known to not be (b)(4) by the (b)(4) This vessel is used to contain non-US plasma (not used for as well as The (b)(4) is used to (b)(4) to and (b)(4) the (b)(4) of, centrifuges and used in the manufacturing process for the swelling …
Contains “cleaning validat*”Read the Form 483 →
Aurobindo Pharma Ltd.Inspection ended Feb 20, 2018 · FEI 3008461619 · Observation 2
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, on the filling machine in suite § which are used for aseptic interventions during the filling operation inside the aseptic fill zone (grade A) had obvious built-up dirt and stains. These ®® | are used for production of injection …
Opens with FDA's citation wording for 21 CFR 211.67(a)Read the Form 483 →
Aurobindo Pharma Ltd.Inspection ended Feb 20, 2018 · FEI 3008461619 · Observation 5
Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance. Specifically, your firm failed to demonstrate the efficacy of the 2 process, which is part of your cleaning activities, to eliminate contaminants in …
Opens with FDA's citation wording for 21 CFR 211.67(b)(3)Read the Form 483 →
Suven Life Sciences Ltd.Inspection ended Feb 15, 2018 · FEI 1000623515 · Observation 2
Equipment and utensils are not cleaned and maintained to prevent contamination that would alter the safety, identity, strength, quality or purity of the Intermediates and APIs manufactured. Specifically, on 05 February 2018 and 08 February 2018, during the inspection of your (b) (4) which are used in the manufacturing process for varied APIs in Production Block-(b) (4) (b) (4) Area. Your firm failed to adequately clean and visually inspect the …
Contains “not cleaned”Read the Form 483 →
Shilpa Medicare LimitedInspection ended Nov 30, 2017 · FEI 3009876430 · Observation 3
Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance. A. Cleaning validation for each product determined how many times the operators need to repeat the cleaning procedure prior to it removing the …
Opens with FDA's citation wording for 21 CFR 211.67(b)(3)Read the Form 483 →
Shilpa Medicare LimitedInspection ended Nov 30, 2017 · FEI 3009876430 · Observation 5
… Microbial testing on swab samples is performed using a pour plate method. The [illegible] media should be [illegible] prior to pouring the [illegible] into the plate containing the sample. This equipment used along with the temperature of the media is not documented. Management confirmed the temperature of the media at this step is critical. F. The monitoring program does not cover all critical surfaces that come in contact with the product. The …
Contains “swab*”Read the Form 483 →
Divi's Laboratories Ltd. Unit IIInspection ended Sep 19, 2017 · FEI 3004149463 · Observation 4
OBSERVATION 4 Your firm has failed to validate the manufacturing cleaning length of time from [illegible] to the [illegible] of production runs for manufacturing equipment to ensure your cleaning procedures are effective for the removal of the build-up of contaminants, degradants and microbes. The length in the chemical synthesis production area is to include equipment such as: reactors, [illegible]. Equipment in the pharma blocks include: …
Contains “validat* … cleaning”Read the Form 483 →
Divi's Laboratories Ltd. Unit IIInspection ended Sep 19, 2017 · FEI 3004149463 · Observation 5
OBSERVATION 5 Your firm does not have adequate cleaning instructions (Issue Control#5) for the major equipment in the Pharma block for [illegible]. Major equipment in the pharma blocks include: [illegible]. The batch cleaning record does not have detailed step by step instructions for how to clean the equipment, what parts to dismantle, supplies needed for cleaning, water temperature or pressure, and the volume of water needed for flushing the …
Contains “cleaning record*”Read the Form 483 →
I.V. Specialty Ltd.Inspection ended Jul 28, 2017 · FEI 3010836489 · Observation 4
… Your pharmacist stated that he fills the bottle with sterile water (b)(4) and uses it to clean "caked" on residue after production in the LAF hood and clean room. C. The sanitizer used in the ISO 7 and ISO 8 rooms (b)(4) is a non-sterile disinfectant.
Contains “residue*”Read the Form 483 →
Vital Rx, Inc. dba Atlantic Pharmacy and CompoundingInspection ended Jul 20, 2017 · FEI 3011775721 · Observation 6
… You do not have documentation to show that these methods are effective in removing and neutralizing these drug residues. Examples of these preparations are as follows: 1.) The progesterone lot 139103 and estriol lot 1608160057 bulk drug substances were used to prepare Rx 060 [illegible] lot 07052017@9. 2.) The progesterone lot 139103 bulk drug substance was also used to prepare Rx [(b)(6)], [(o)(4)], [(b)(1)] estradiol/progesterone/DHEA …
Contains “residue*”Read the Form 483 →
Pharmacy Specialists of Central FL Inc., dba Pharmacy SpecialistsInspection ended Jun 8, 2017 · FEI 3003785869 · Observation 1
… detergent, reverse osmosis water rinse, and [(b) (4)] of the mixing mill equipment; you do not show that these methods are effective in removing these drug residues. Examples of these preparations are as follows: A. Fluoromacil 5% cream lot [(b) (4)] used to prepare 5-fluoromacil 2.5% / calcipotriene 0.0025% cream [(b) (4)] B. Testosterone USP lot [(b) (4)] used to prepare testosterone 50 mg/g in 10 mg [illegible] cream lot [(b) (4)]
Contains “residue*”Read the Form 483 →
ARJ Infusion Services, Inc.Inspection ended May 25, 2017 · FEI 3013452490 · Observation 3
… (b) (4) upon entry/re-entry into the laminar air flow hood • cleaning of the laminar air flow hood was not performed per your procedure(s) • components were not adequately cleaned before placement into the laminar air flow hood • written cleaning procedures and records do not verify the use of sporicidal cleaning agents used to clean the laminar air flow hood.
Contains “not adequately cleaned”Read the Form 483 →
DNA Pharmacy Services dba Palm Beach CompoundingInspection ended May 23, 2017 · FEI 3004962739 · Observation 1
… You do not have documentation to show that these methods are effective in removing and neutralizing these drug residues. Examples of these preparations include: (b)(4) (b)(4) A. Testosterone , lot , drug substance was used to prepare "Test/DHEA/Prog/Anastrozole" troche butterscotch 110/10/5/0.5mg, lot 04/21/2017:0308. B. Estriol, estradiol, progesterone, testosterone (lots (b)(4), and (b)(4) respectively) drug substances were used to prepare …
Contains “residue*”Read the Form 483 →
Tiberius, Inc., dba Custom Scripts PharmacyInspection ended May 18, 2017 · FEI 3004358166 · Observation 2
… You do not have documentation to show that these methods are effective in removing and neutralizing these drug residues. Examples of these preparations are as follows: A. The fluorouracil lot (b) (4) bulk drug substance was used to prepare 5-fluorouracil 5%/HC 1% cream lot 0716Cl3. B. The estriol lot (b) (4) bulk drug substance was used to prepare estriol mg/gm VC cream lot E0517Cl0.
Contains “residue*”Read the Form 483 →
J.W. Platt, RPh LLC., dba The Wellness PharmacyInspection ended May 16, 2017 · FEI 3011402879 · Observation 2
OBSERVATION 2 Equipment and utensils are not cleaned appropriately to prevent contamination of drug products. Specifically, On May 10, 2017 we observed a technician clean the (b) (4) of an (b) (4) after producing BI-EST Cream (9:1) of (b) (4) pursuant to (b) (6), (b) (7)(C). The (b) (4) are direct product contact surfaces. The (b) (4) were cleaned using a discolored rag that had been sitting near the sink. The rag was (b) (4) and used to (b) (4) …
Contains “not cleaned”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.67Equipment cleaning and maintenanceIn this theme's rule31
- 21 CFR 211.113Control of microbiological contamination10
- 21 CFR 211.42Design and construction features6
- 21 CFR 211.22Responsibilities of quality control unit3
- 21 CFR 211.100Written procedures; deviations2
- 21 CFR 211.192Production record review2
- 21 CFR 211.28Personnel responsibilities1
- 21 CFR 211.56Sanitation1
- 21 CFR 211.58Maintenance1
- 21 CFR 211.94Drug product containers and closures1
Ask FDAgent about equipment cleaning in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.