Skip to content

DNA Pharmacy Services Inc dba Palm Beach Compounding

2151 S Highway A1a Alt Ste 1500, Jupiter, Florida, United States

FEI 3004962739

FDA has 2 inspections on file for DNA Pharmacy Services Inc dba Palm Beach Compounding in Jupiter, Florida (FEI 3004962739), from 2014 to 2017. The latest ended on and was classified VAI, voluntary action indicated. FDA has also posted a Form 483 dated Jul 21, 2017 that FDAgent has not matched to an inspection on the Data Dashboard.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its one observation from the PDF; it is listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
2, 2014–2017
0 OAI · 2 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
2 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
2 posted
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate cleaning causing cross-contamination

      Hazardous drugs were produced without providing adequate cleaning of utensils and work surfaces to prevent cross-contamination. Specifically, I observed the (b)(4) used to (b)(4), was stored in alcohol between use rather than cleaned (detergent and sanitized). You do not have documentation to support the cleaning (b)(4) practices and maintenance of the [illegible]. Also, your operations include the preparation of non-sterile drug products that contain hormones, such as testosterone and progesterone, using reusable equipment that was cleaned with a (b)(4) with (b)(4) detergent or (b)(4) with (b)(4) soap. Working surfaces are wiped down using (b)(4). You do not have documentation to show that these methods are effective in removing and neutralizing these drug residues. Examples of these preparations include: (b)(4) (b)(4) A. Testosterone , lot , drug substance was used to prepare "Test/DHEA/Prog/Anastrozole" troche butterscotch 110/10/5/0.5mg, lot 04/21/2017:0308. B. Estriol, estradiol, progesterone, testosterone (lots (b)(4), and (b)(4) respectively) drug substances were used to prepare "Bi-est/prog/test" troche butterscotch 2.5/50/1.5mg, lot 05/15/2017:0251. This is a repeat observation from Form FDA-483, dated 08/13/14.

  3. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate stability testing

      There is no written testing program designed to assess the stability characteristics of drug products. Specifically, there is no data to justify the beyond use date of more than 9 months for Testosterone Cypionate Injection 220 mg/mL Lot 03/02/2014:1106 that you produced on 03/02/2014 and currently distribute with a BUD of 12/27/2014. The stability data you generated for this product only supports a BUD of 3 months.

    2. Observation 2

      No sterility/endotoxin testing

      Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements. Specifically, Testosterone Cypionate Injection 220 mg/mL Lot 03/02/2014:1106 produced on 03/02/2014 is currently distributed with a BUD of 12/27/2014 (9 months) even though there is no current sterility and endotoxin testing data to demonstrate that this lot is safe, effective, and stable for nine months.

    Show observation 3
    1. Observation 3

      Equipment maintenance and contamination risk

      Equipment and utensils are not maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, during the walkthrough observed white residue and scratches inside the [illegible] (a component used as part of the high-torque [illegible] blender) used to [illegible] inactive pharmaceutical ingredients before encapsulation. Additionally, materials blended using the [illegible] blender are not tested to ensure that the high-torque and friction do not negatively affect the finished product quality attributes.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3004962739 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3004962739. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.