Skip to content

Tiberius, Inc.

27732 Cashford Cir, Wesley Chapel, Florida, United States

FEI 3004358166

FDA has one inspection on file for Tiberius, Inc. in Wesley Chapel, Florida (FEI 3004358166). It ended on and was classified VAI, voluntary action indicated. FDA has also posted a Form 483 dated Jul 26, 2017 that FDAgent has not matched to an inspection on the Data Dashboard.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 2 observations from the PDF; they are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
1, in 2017
Inspections with 483 observations shown
1 of 1
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Use of non-pharmaceutical grade components

      Observation 1: Non-pharmaceutical grade components are used in the formulation of non-sterile drug products. Specifically, non-sterile drug preparations both oral and topical use (b) (4) [illegible] water rather than a purified USP grade water. Examples of these include: A. Magic mouthwash #50 ((b) (4)) lot A0913Cl9 B. HQ 4% REG He Pump1 (b) (4) lot E1517C9

    2. Observation 2

      Inadequate cleaning for hazardous drugs

      Observation 2: Hazardous and highly potent drugs were prepared and handled without providing adequate cleaning of work surfaces and reusable equipment such as spatulas, [illegible] and the [illegible] to prevent cross-contamination. Specifically, your operations include the preparation of non-sterile drug products that contain anti-neoplastic agents such as fluorouracil and hormones such as estriol using reusable equipment that was [illegible] cleaned using [illegible] water, (b) (4) and (b) (4). Working surfaces are wiped down using (b) (4). You do not have documentation to show that these methods are effective in removing and neutralizing these drug residues. Examples of these preparations are as follows: A. The fluorouracil lot (b) (4) bulk drug substance was used to prepare 5-fluorouracil 5%/HC 1% cream lot 0716Cl3. B. The estriol lot (b) (4) bulk drug substance was used to prepare estriol mg/gm VC cream lot E0517Cl0.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3004358166 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3004358166. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.