Cohance Lifesciences Limited
Plot Nos 262-271, Ida Pashamylaram, Sangareddy, India
FEI 1000623515DUNS 677604288
FDA has 7 inspections on file for Cohance Lifesciences Limited in Sangareddy, India (FEI 1000623515), from 2009 to 2024. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
One FOIA request asked FDA for the 483 from a later inspection, ending Aug 5, 2026, that FDA's Data Dashboard doesn't list yet.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, API manufacturing, packing, labeling and analysis, through Dec 31, 2026. Its registrant is Cohance Lifesciences Limited (D-U-N-S 861468675).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 7, 2009–2024
- 0 OAI · 5 VAI · 2 NAI
- Inspections with 483 observations shown
- 1 of 7
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 1 request, latest Aug 6, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Computer controls lack audit trail review
Appropriate controls are not exercised over computer or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, A. Your firm has a total of (b) (4) HPLCs and (b) (4) UPLCs used to analyze raw material, finished product, and related substances for products marketed and distributed to the US. The HPLCs and UPLCs use either Empower 3 or EZ CHROM ELITE, which have audit trail capabilities. However, your firm could not provide documentation these audit trails have been electronically reviewed by quality personnel. B. Your firm's Manager of Quality Assurance and Deputy Manager of QC verified your firm did not conduct electronic data review for any analysis performed in the QC Formulations Laboratory prior to August 2017.
- Observation 2
Equipment not cleaned and properly maintained
Equipment and utensils are not cleaned and maintained to prevent contamination that would alter the safety, identity, strength, quality or purity of the Intermediates and APIs manufactured. Specifically, on 05 February 2018 and 08 February 2018, during the inspection of your (b) (4) which are used in the manufacturing process for varied APIs in Production Block-(b) (4) (b) (4) Area. Your firm failed to adequately clean and visually inspect the following (b) (4) A. (b) (4)-3109 is used in the production of (b) (4) API/Intermediate: I observed what appears to be discoloration resembling (b) (4) inside the (b) (4) 3109 in areas that come into direct contact with drug product. The status of this non-dedicated (b) (4) was identified as cleaned. B. (b) (4)-3139: I observed the gasket used to protect the (b) (4) and the (b) (4) of (b) (4) 3139 was wrapped in Teflon tape and starting to unravel. I observed what appeared to be missing pieces of the Teflon tape at the bottom of the (b) (4). In addition, I observed what appeared to be a white, powdery residue along the inside of the (b) (4). The status of this equipment was identified as cleaned and a visual inspection was documented in the Equipment Use Logbook. C. (b) (4)-3137: I observed what appears to be (b) (4) residue and black residue alongside the sides of this (b) (4). In addition, I observed the (b) (4) bolts located on the bottom of the (b) (4) that comes in direct contact with drug products to have a (b) (4) discoloration. I observed a hole at the bottom of the (b) (4) indicating this (b) (4) is damaged. The Equipment Use Logbook documents the equipment qualifications were completed on 29 December 2017 and the status of this non-dedicated equipment was identified as cleaned.
Show observations 3 to 7
- Observation 3
Deficient batch records missing verifications
Manufacturing Batch Records are deficient. Specifically, A. On 13 February 2018, your firm failed to document in-process checks during the manufacturing of the drug product, (b) (4) Tablets, Batch #(b) (4) on Form, F/CQO-F/320, as outlined in Step (b) (4) of the Batch Manufacturing Record. However, this step was verified by your firm's Quality Assurance. B. Recorded weights are not verified by a second verifier.
- Observation 4
Raw material sampling procedures not followed
Procedures for sampling of raw materials were not followed. Specifically, on 05 February 2018, I observed the raw material, (b) (4) (Batch #(b) (4)) did not contain the appropriate number of sampled containers as written in your firm's written procedures for raw material sampling (SOP/CQO/3024).
- Observation 5
Uncontrolled access to label storage room
Label access is not controlled. ***THIS IS A REPEAT OBSERVATION*** Specifically, the label storage room that contains printed packaging materials for (b) (4) Capsules and (b) (4) Tablets was observed to be unlocked by your firm's Corporate Quality Manager during a walkthrough of production on 12 February 2018.
- Observation 6
Employees lack required cGMP training
Employees engaged in the manufacture, processing, packing, and holding of a drug product lack the training required to perform their assigned functions. ***THIS IS A REPEAT OBSERVATION*** Specifically, your firm failed to conduct cGMP training for (b) (4)% of (b) (4) selected employees performing Quality related functions, such as, production, quality control, and quality assurance in 2016.
- Observation 7
Product quality reviews are deficient
Your firm's Product Quality Reviews (PQRs) are deficient. Specifically, A. 2017 PQR for (b) (4) Capsules (review period January 2016 - December 2017): 1. Does not address corrective and preventative actions implemented for out of specification (OOS16-005) for (b) (4) content for (b) (4) Capsules (b) (4) mg, Batch #(b) (4) 2. Is missing change control (EN/CCP/17/5036) for the installation of new equipment in the packing line ((b) (4) Inserting Machine, (b) (4) Machine, (b) (4) Labeling Machine, (b) (4) Overprinting, Leaflet in Outserter Machine, and Torque Machine), which were qualified and installed in 2017. 3. In addition, your firm's written procedures for Product Quality Review (SOP/CQO/3021), defines the product review period as a calendar year from January to December. However, the 2017 PQR for (b) (4) covers a review period of January 2016 - December 2017. A Deviation was not provided. B. Your firm's PQR for (b) (4) Tablets does not address corrective and preventative actions implemented for an out of specification (OOS) for the following: 1. OOS 17-002: Unknown impurity peaks were found in (b) (4) Tablets, Batch #(b) (4), dated 7 March 2017. 2. OOS 17-003: Sub-potent assay results for (b) (4) tablets, Batch #(b) (4) and Batch #(b) (4) dated 17 March 2017. C. Your firm's APQR for (b) (4) Capsules does not address corrective and preventative actions implemented for an out of specification (OOS) for the following: 1. OOS 17-002: Unknown impurity peaks were found in (b) (4) Capsules, Batch #(b) (4) dated 7 March 2017.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Aug 6, 2026. It asked for a Form 483.
Inspection ending Aug 5, 2026
1 request. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on Aug 12, 2026. FDAgent holds no copy that FDA posted.
- Aug 6, 2026FDA-FOIA-2026-7580Form 483Records released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, API manufacturing, packing, labeling, analysis
- Registration runs through
- Dec 31, 2026
- Registrant
- Cohance Lifesciences LimitedD-U-N-S 861468675
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other FEIs recorded as Cohance Lifesciences Limited
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Cohance Lifesciences LimitedFEI 3005554260Krishna District, India
Last inspected 2025-09-11NAI
Cohance Lifesciences LimitedFEI 3008768274India
Last inspected 2025-08-12
Cohance Lifesciences LimitedFEI 3006493505Medchal-Malkajgiri, India
Last inspected 2025-03-07VAI
Cohance Lifesciences LimitedFEI 3003650383Ankleshwar, India
Last inspected 2023-04-14NAI
Cohance Lifesciences LimitedFEI 3009291635Hyderabad, India
Last inspected 2023-01-26VAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1000623515 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1000623515. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.