Skip to content

Cohance Lifesciences Limited

India

FEI 3008768274DUNS 677637710

Company: COHANCE LIFESCIENCES LIMITED · Linked by exact D-U-N-S match (857960750) in FDA registration data

FDA has 5 inspections on file for Cohance Lifesciences Limited in India (FEI 3008768274), from 2013 to 2025. The latest ended on ; FDA has not posted its classification yet. FDA issued a warning letter on (CDER).

FDA posted the Form 483 from that inspection. FDAgent read its 6 observations from the PDF; they are listed below. One of the two FOIA requests for this site has asked FDA for this inspection's 483.

No court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2026. Its registrant, COHANCE LIFESCIENCES LIMITED (D-U-N-S 857960750), has registered 1 other site.

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
5, 2013–2025
0 OAI · 4 VAI · 0 NAI
Inspections with 483 observations shown
3 of 5
Form 483s posted by FDA
↗
Requested under FOIA
2 requests, latest Nov 21, 2025
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. Not classified yetClassification not posted yetPosted 483 · 6 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Failure to investigate discrepancies

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been [illegible]. Specifically, A) There is no documentation on the disposition status and reconc[iliation] of rejected [illegible] that have gone missing after being rejected on August [illegible]. Deviation DEV/NCR/23/0033, Deviation Initiation Date: June 19, 2023. Specifically, total containers, which consists of [illegible] fallen on the floor from the packing line (b)(1-4). According to the final investigation report entire batch due to the high number physical characteristics for all compressed [illegible]. Assurance (QA), the rejected batch has not been disposed of as approximately 23 months since the final investigation report and Production department in August 2023. However, only [illegible] out consists of [illegible] wc1 out of the I warehouse facility during my inspection walkthrough on August 0. The Assistant General Manager of QA and Senior General Manager of Operations stated that they were unable to explain the discrepancy and unable to account for [illegible] Batch No CtiTC which was initially in [illegible]. B) OOS/IP/21/020 was initiated on March 30, 2021, due to [illegible] Batch No [illegible], Mfg. Date: 03/2021, Exp. Date: [illegible], specification limits for [illegible] but ultimately rejected due to the [illegible] and subsequently leading to inadequate [illegible]. In the personnel interview section, it was understood that the [illegible] missed by the Operator due to assumption in verification. The investigation further stated that since the executed processing step is performed [illegible] during CtiTC, unavailability of operator for missing the step is in further assessment and preventive actions initiated to address the process and operational gaps that may continue to remain during critical manufacturing and packing. C) OOS/QC/23/010 was initiated on April [illegible] for [illegible] mg, (b)( ) mg, (b)( ) mg and [illegible] (out-of-specification OOS) (Specification: [illegible] Sample Set [illegible]). A root cause was identified for the S[illegible] and proposed to collect the (b)( ) (instead of Cb>< vials) to eliminate error during [illegible]; however, no further hypothesis testing, or detailed assessment was performed. According to the Assistant General Manager of Quality Assurance, there is no documentation or record onsite for extractable and leachable studies being performed for packaging of all tablets and for filling operations. During the current inspection, your firm was unable to provide any documentation of extractable and leachable studies performed for the filling operations.

    2. Observation 2

      Incomplete complaint follow-up

      Written records of investigation of a drug complaint do not include the follow-up. Specifically, A) Complaint #PC/NCR/FDF/23-020 was filed on October [illegible] for tablets USP [illegible]. The pharmacy reported that the tablets were crumbly, disintegrating, pitted, had dust and did not have crisp markings on the tablet. Based on the investigation, control/reference sample resembled [illegible] and the probability of generation of powder [illegible]; the subjected complaint was considered [illegible] and preventive actions were initiated. However, there was no stability specification established to [illegible] chipped edges and disintegrating like physical characteristics. These physical characteristics were also observed during review of retained samples. The General Manager of Quality Assurance (QA) [illegible] original complainant sample for comparison purposes and [illegible]. Furthermore, SOP QA084-02, Field Alert Report, Effective Date: December 31, 2022 states the following are some examples which need [illegible] Crumbled, broken, disintegrated [illegible] documented explanation as to why there [illegible] to potentially filing a U.S. FDA field alert. B) Complaint #PC/NCR/FDF/24-024 was initiated [illegible] for CbTCl Tablets, (b)( )-4 mg, Batch No. [illegible]. A grade piece of glove, which is/could be a finger [illegible], was found in a bottle on April 23, 2024. It was determined [illegible] and CAPA/030/24 was initiated on June 24, 2024, Handling of Gloves in Manufacturing and Packing. However, the SOP does not include provisions to address potential future incidences concerning ripped pieces of gloves.

    Show observations 3 to 6
    1. Observation 3

      QC procedures and access controls lacking

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically, A) Complaint investigations that are involved with field alerts are not consistently recorded in the Field Alert Report Log (Annexure I) for further follow-up and reference as per SOP QA084-02, Field Alert Report, Effective Date: December 31, 2022. Documentation in the Field Alert Report: Customer complaint dated December 04, 2020 by the customer for Manufacturing, Date: 01/2020, Exp. Date: [illegible], seal bottle had [illegible] tablets under the strength. Initial FAR Date: December 08, 2020, Final FAR Date: December [illegible]. The General Manager of Quality Assurance stated unawareness by the QA department. B) There is no instrument usage log for Analytical Balance #PD/A [illegible] for in-process analytical testing of compressed tablets in Production Block [illegible]. In addition, the instrument usage log for friability test apparatus PD/FBL-01 has not been completed as per SOP PD240-02 Operation, Cleaning and Calibration of Friability Test Apparatus, Effective Date: October 28, 2023, section 6.2 Annexure II, Usage Log for Friability Test Apparatus (PD240-F02-01). According to Quality Assurance (QA), this was due to procedural unawareness by operators and QA. C) There is no documented rationale and quality risk assessment for passwords shared amongst production personnel for manufacturing equipment Human Machine Interface (HMI). For example, operators are provided with the supervisor level password for PD CbTc401 and Operation of CbH1 (Capacity) despite the software vendor manual stating that supervisor level password prevents access to program details, and it should be known only to the supervisor or in charge of the plant. The supervisor level user access allows for edits to process time (total cycle time), CbTC off time (time during which [illegible] is taking place), CbH1 On and Off (time duration during which [illegible]), CbTC set point, and other parameters. The following additional manufacturing systems also have shared user IDs and passwords for Production Block [illegible] assigned supervisor level access: [illegible]. D) On August 06, 2025, I observed that the Packaging Supervisor was able to cut and delete logged software audit trail data and packaging batch data files within the Countee Data System Windows application account used [illegible]. The account login is also shared between operators and packaging supervisors. According to the IT Administrator, this was an oversight.

    2. Observation 4

      Poor equipment cleaning and maintenance

      Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, A) During the inspectional walkthrough on August 4, 2025 I observed within I CbTCl PD, which remains open during CbH operations, visible product residue which remains on equipment used to manufacture finished drug products intended for U.S. and global markets. PD/Cb 01 was last used to manufacture CbTC4l tablets [illegible] mg, [illegible] mg, and [illegible] (Type-B) cleaning being completed [illegible] reported after swab sampling performed as per the current inspection request. An additional peak in the sample chromatogram was identified to be traces of (bT(4) which is a [illegible] treatment of (b)(1). The identified peak for [illegible] corresponds to previously last manufactured product: swab analysis results for (b)( ) Tablets [illegible]. Additional drug product batches have been manufactured on the equipment since then for the U.S. and other global markets. B) During the inspectional walkthrough on August 4, 2025 I observed on the I CbTCl upper and outer surfaces, corner surface of the equipment reservoir, and outer surface of the empty capsules reservoir within Capsule filling machine PD/CFM-03. PD/CFM-03 was last used to manufacture [illegible] mg, Batch No. [illegible] on July 22, 2025, prior to product changeover cleaning being completed on July 24, 2025. However, the following test results were reported after swab sampling performed as per the current inspection request on August 4, 2025: [illegible]. This is despite the following product changeover cleaning steps being signed and verified: (b)( ) [illegible]. C) On August 08, 2025, the following poor equipment conditions were observed for Compression Machine PD/TCM-03 located in Production Block [illegible] for the U.S. market: stains and spots observed on the [illegible]; visible dents on the [illegible]; damaged/chipping [illegible]; (b)( ) stains were observed across [illegible]; a shiny metal particle found on the [illegible]. The equipment was last used to manufacture [illegible] intended for the U.S market. D) During my inspection walkthrough on August 04, 2025, I observed what appeared to be very visible inner stress cracks and scratches within the PD CbTc401 bowl. PD CbTc401 is routinely used for drug products distributed to the U.S. and other global markets, including: [illegible] and [illegible] last manufactured on May 9, 2025. There has been no incident report raised or maintenance check conducted for this matter until the current inspection. E) During my inspection walkthrough on August 06, 2025, two visible large cracks were observed within the I Cbnj directly above the tablet and capsule exit of Counting Machine ID: PD/TCC-03. According to the Packaging Supervisor, the cracks had recently occurred. However, there was no incident occurrence, or maintenance check conducted for this matter until the current inspection.

    3. Observation 5

      Inadequate cleaning validation procedures

      Written procedures are not established for the cleaning and maintenance of equipment and utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, A) Your firm's cleaning validation revised Protocol No. E [illegible] Protocol, Effective Date: January 25, 2019, established (Total Score: [illegible]) as the worst-case product to conduct cleaning validation study for dedicated equipment product contact surfaces used to produce U.S. and non-U.S. marketed finished drug products. This was based on a total score considering toxicity, solubility and hardest-to-clean considerations. However, there is no justification as to why I CbTCl tablets (Total Score: [illegible]) were not included in the cleaning validation study and 2023 reclean of product contact surfaces, given the following total scores reported: Total score based on Toxicity, Solubility, and Hardest-to-clean considerations: [illegible]. During the inspection, the Assistant General Manager of Quality Assurance (QA) stated that [illegible] tablets, Total Score: [illegible] was identified as the hardest-to-clean product and was selected to conduct the cleaning validation study due to [illegible] (MACO) limit. B) Since the 2018 cleaning validation, there has been no further evaluation nor revalidation study for more than [illegible] newly introduced finish types, product toxicity, solubility, and hardest-to-clean considerations for shared equipment product contact surfaces including [illegible]. In addition, cleaning validation study for certain finished drug products dating back to 2015 was performed without any written justification on the frequency, timeline, drug product selection, and selection of only some hardest-to-clean areas for swab analysis versus all hardest-to-clean areas reviewed during visual inspection. C) There is no documented scientific rationale showing the cleaning validation study representative for all finished drug product contact surfaces. The validation study protocol and report did not assess the differences in physical properties and manufacturing processes for various types and instead selected [illegible] as the sole drug product to conduct the cleaning validation. D) SOP PD291-01, Operation and Cleaning of Tablet Compression Machine, Effective Date: March [illegible] instructs operators to solely use (b)( ) for cleaning the compression machine and tablet compression machine surfaces. However, the original cleaning validation study was evaluated for [illegible] residue for all surfaces. According to QA, the firm has decided to use WCl as part of their routine cleaning to prevent rusting of equipment surfaces. QA stated the decision to change the cleaning validation program was due to an oversight. E) During my inspection walkthrough on August 4, 2025, I observed [illegible] stored within Module [illegible] area, Production [illegible]. According to the Production Manager, the Cb[n] was [illegible] and is instead used in PD CbH4l_04. Equipment ID: [illegible]. The Senior General Manager of Operations was unable to explain why, how, and when the Cb[n] was placed in a different drug production area for a different product.

    4. Observation 6

      Unvalidated laboratory test methods

      The accuracy, sensitivity, specificity and reproducibility of test methods have not been established. Specifically, A) The (b)(TC4l) analytical method for [illegible] mg, [illegible] mg, and (b)( ) mg, which is routinely used for in-process testing, has not been evaluated for accuracy, sensitivity, specificity and reproducibility according to the Assistant General Manager of QA. This includes lack of evaluation and suitability of sample mass differences. For example, [illegible]. B) The (b)(TC4l) analytical test method for [illegible] mg, [illegible] mg and (b)( ) mg has not been validated for assay sample preparation steps for release and stability testing versus [illegible]. Unique Batch Product Name Identifier Number and Strength: (tiJ{4}) bOS/QC/23/010 Tablets USP [illegible] mg, [illegible] mg, [illegible] mg and [illegible] mg In-process CbT(4); bOS/QC/22/018 tablets USP [illegible] mg [illegible] and [illegible] mg In-process CbT(4); POS/IP/21/033 tablets USP [illegible] mg. Reproducibility according to the Assistant General Manager has not been evaluated for the (b)( ) sample preparation procedure. DATES OF INSPECTION: 8/04/2025 (Mon), 8/05/2025 (Tue), 8/06/2025 (Wed), 8/07/2025 (Thu), 8/08/2025 (Fri), 8/11/2025 (Mon), 8/12/2025 (Tue).

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Approve or reject procedures or specs

      The quality control unit lacks responsibility to approve and reject all procedures or specifications impacting on the identity, strength, quality and purity of drug products.

    2. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.

    3. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans designed to assure that in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Written in-process control procedures

      Written procedures are not followed that describe the in-process controls to be conducted on appropriate samples of in-process materials of each batch.

    2. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing.

    3. Control procedures to monitor and validate performance

      Control procedures are not established which of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    4. Failure to meet specifications

      An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning a failure of one or more distributed batches of a drug to meet the specifications established for it in the application.

  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on Nov 21, 2025.

  • Inspection ending Aug 12, 2025Not classified yet

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Sep 22, 2025FDA-FOIA-2025-11167Form 483Records released
  • Inspection ending Aug 20, 2019VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Nov 21, 2025FDA-FOIA-2025-13192Inspection records· 1 of 2 sitesWithdrawn

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 5 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 5 inspections, with how many of them cited each.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing
Registration runs through
Dec 31, 2026
Registrant
COHANCE LIFESCIENCES LIMITEDD-U-N-S 857960750

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names COHANCE LIFESCIENCES LIMITED (D-U-N-S 857960750) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Other FEIs recorded as Cohance Lifesciences Limited

Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3008768274 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3008768274. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.