Skip to content

The Wellness Pharmacy

2228 Papermill Rd Ste E, Winchester, Virginia, United States

FEI 3011402879

FDA has 2 inspections on file for The Wellness Pharmacy in Winchester, Virginia (FEI 3011402879), from 2015 to 2017. The latest ended on and was classified VAI, voluntary action indicated. FDA has also posted a Form 483 dated Jul 24, 2017 that FDAgent has not matched to an inspection on the Data Dashboard.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 2 observations from the PDF; they are listed below.

The most recent OAI inspection ended on Mar 12, 2015. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
2, 2015–2017
1 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
2 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
2 posted
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Use of non-dedicated discolored spatulas

      OBSERVATION 1 Utensils used for drug preparation are potentially absorptive or additive such that they may alter the purity, identity, or strength of a drug product. Specifically, A. On May 10, 2017 we observed the preparation of hormonal BI-EST cream (b) (4) (b) (6), (b) (7)(C) pursuant to Rx During preparation we observed a rubber spatula was used for mixing. The spatulas are cleaned after use with tap water and soap and placed in a drawer for reuse. We observed discolored spatulas in the drawer for use for mixing drug products. The spatulas are not dedicated for the production of hormonal or other products.

    2. Observation 2

      Inadequate cleaning; dirty rags used

      OBSERVATION 2 Equipment and utensils are not cleaned appropriately to prevent contamination of drug products. Specifically, On May 10, 2017 we observed a technician clean the (b) (4) of an (b) (4) after producing BI-EST Cream (9:1) of (b) (4) pursuant to (b) (6), (b) (7)(C). The (b) (4) are direct product contact surfaces. The (b) (4) were cleaned using a discolored rag that had been sitting near the sink. The rag was (b) (4) and used to (b) (4) was in operation. A final rinse was performed with (b) (4) and the same discolored rag. On May 16, 2017 we observed four rags resting on the sink and counter top next to the sink. There were two dirty glass beakers with glass stir bars in the sink. During the preparation of Hydroquine-Trentin-HC (b) (4) cream (b) (6), (b) (7)(C) (b) (4) (b) (4) pursuant to Rx, I observed the technician clean the [illegible] of the [illegible] with one of the rags from the sink. The rag was (b) (4). The final rinse was performed with (b) (4).

  3. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  4. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Defined areas of adequate size for operations

      The control systems necessary to prevent contamination or mix-ups are deficient.

    2. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed.

    3. Sterility/pyrogen-free testing

      Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.

    4. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.

Regulations FDA cited here

The 4 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 2 inspections.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3011402879 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3011402879. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.