Skip to content

Titan Kogyo, Ltd.

1727-1, Oazatsumazakigaisaku, Ube, Japan

FEI 3009155994DUNS 706280823

FDA has 2 inspections on file for Titan Kogyo, Ltd. in Ube, Japan (FEI 3009155994), from 2017 to 2023. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 4 observations from the PDF; they are listed below.

No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, through Dec 31, 2027. Its registrant is Titan Kogyo , Ltd. (D-U-N-S 690564729).

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
2, 2017–2023
0 OAI · 2 VAI · 0 NAI
Inspections with 483 observations shown
1 of 2
Form 483s posted by FDA
↗
Requested under FOIA
2 requests, latest Jun 29, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Use of untested unreleased raw materials

      The firm's Production Unit utilizes critical raw materials within the manufacturing process prior to the completion of identification testing and release of the raw materials by the firm's Quality Control Unit. For example: (b) (4) lot# (b) (4) was received and sampled on 07/12/2023. Identification testing was conducted from 08/03/2023 - 08/08/2023 and the lot of (b) (4) was released by Quality Control on 08/09/2023; however, the raw material was utilized in the manufacturing of (b) (4) API (b) (4) lot#(b) (4) on 07/31/2023. (b) (4) lot# (b) (4) was received and sampled on 07/28/2023. Identification testing was conducted on 08/03/2023 and the lot of (b) (4) was released by Quality Control on 08/04/2023; however, the raw material was utilized in the manufacturing of (b) (4) API (b) (4) lot#(b) (4) on 07/31/2023. (b) (4) lot# (b) (4) was received and sampled on 06/13/2022. Identification testing was conducted on 06/18/2022 and the lot of (b) (4) was released by Quality Control on 06/20/2022: however, the raw material was utilized in the manufacturing of (b) (4) API (b) (4) lot#(b) (4) on 06/19/2022.

    2. Observation 2

      Non-stability-indicating assay for stability program

      The firm's stability program was inadequate in that the firm's QC Laboratory failed to utilize a stability indicating method for assay testing of (b) (4) The QC Laboratory utilizes a titration method for assay testing of (b) (4) for all stability testing that the firm has conducted on their (b) (4) API products including the following US marketed API: (b) (4) For example, the firm utilized the titration assay method for the accelerated stability studies of (b) (4) API (lot#s(b) (4) The data from the accelerated stability studies was later utilized to determine the shelf life of the product. The firm has no data to support the use of the titration assay method as a stability indicating method or that it has the ability to detect impurities or degradants over the shelf life of the API.

    Show observations 3 to 4
    1. Observation 3

      Incomplete verification of supplier COAs

      Verification testing of the raw material supplier COA is inadequate as the firm has failed to conduct all of the analyses listed on the respective supplier COA. For example: The (b) (4) lot# (b) (4) COA from (b) (4) lists the following analyses: appearance, specific gravity, (b) (4) (b) (4) The firm's verification testing of the aforementioned supplier COA only included the following: specific gravity, (b) (4) The (b) (4) lot# (b) (4) COA from (b) (4) lists the following analyses: purity, ignition on residue, moisture, (b) (4) foreign matter. The firm's verification testing of the aforementioned supplier COA only included the following: purity and ignition on residue. The (b) (4) lot (b) (4) COA from (b) (4) lists the following analyses: (b) (4) concentration, (b) (4) specific gravity, (b) (4) and viscosity. The firm's verification testing of the aforementioned supplier COA only included the following: (b) (4) concentration, (b) (4) and specific gravity.

    2. Observation 4

      Inadequate cleaning and maintenance of equipment

      Equipment and utensils utilized in the production of API for the US Market are not cleaned or maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, purity and quality of the drug substance. For example: Reddish-brown discoloration was observed on the interior of the water hose to holding vessel (RT-8). The aforementioned hose is utilized in the pumping of water into the ceiling of the vessel to prevent (b) (4) from escaping. The holding vessel is utilized in the manufacturing of (b) (4) API (b) (4) Reddish-brown discoloration was observed on the interior of the water hoses to (b) (4) (GM-5). The aforementioned hoses are utilized in the pumping of water to cool the interior of the vessel. The (b) (4) is utilized in the manufacturing of (b) (4) API (b) (4) White powder residues were observed on the exterior of the Kubota scale within the Line (b) (4) sampling room. The aforementioned scale is utilized in the weighing of critical raw materials used for the manufacturing of (b) (4) (b) (4) API. According to the management team, the scale was reported to have been cleaned; however, the firm does not document any cleaning activities within the sampling room. The firm utilizes a (b) (4) sampling tool during the (b) (4) API (b) (4) manufacturing process. The sampling tool is utilized at various points of the initial process including (b) (4) (b) (4) According to the management team, the sampling tool is reported to be cleaned in-between uses, however, the cleaning of the sampling tool is not documented.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on Jun 29, 2026.

  • Inspection date not given

    2 requests. FDA released records in answer to a request for its Inspection records on Jul 6, 2026. FDAgent holds no copy that FDA posted.

    1. Jun 29, 2026FDA-FOIA-2026-6198Inspection records· 1 of 3 sitesRecords released
    2. Dec 14, 2023FDA-FOIA-2023-11142Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing
Registration runs through
Dec 31, 2027
Registrant
Titan Kogyo , Ltd.D-U-N-S 690564729

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3009155994 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3009155994. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.