Titan Kogyo, Ltd Form 483, December 2023
FDA issued this Form 483 to Titan Kogyo, Ltd in Ube, Japan (FEI 3009155994) at the end of a drug inspection that ended December 8, 2023. It lists 4 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 5, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Dec 8, 2023
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Nov 5, 2026
- 1,063 days after the inspection
The 4 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Use of untested unreleased raw materials
The firm's Production Unit utilizes critical raw materials within the manufacturing process prior to the completion of identification testing and release of the raw materials by the firm's Quality Control Unit. For example: (b) (4) lot# (b) (4) was received and sampled on 07/12/2023. Identification testing was conducted from 08/03/2023 - 08/08/2023 and the lot of (b) (4) was released by Quality Control on 08/09/2023; however, the raw material was utilized in the manufacturing of (b) (4) API (b) (4) lot#(b) (4) on 07/31/2023. (b) (4) lot# (b) (4) was received and sampled on 07/28/2023. Identification testing was conducted on 08/03/2023 and the lot of (b) (4) was released by Quality Control on 08/04/2023; however, the raw material was utilized in the manufacturing of (b) (4) API (b) (4) lot#(b) (4) on 07/31/2023. (b) (4) lot# (b) (4) was received and sampled on 06/13/2022. Identification testing was conducted on 06/18/2022 and the lot of (b) (4) was released by Quality Control on 06/20/2022: however, the raw material was utilized in the manufacturing of (b) (4) API (b) (4) lot#(b) (4) on 06/19/2022.
- 2
Non-stability-indicating assay for stability program
The firm's stability program was inadequate in that the firm's QC Laboratory failed to utilize a stability indicating method for assay testing of (b) (4) The QC Laboratory utilizes a titration method for assay testing of (b) (4) for all stability testing that the firm has conducted on their (b) (4) API products including the following US marketed API: (b) (4) For example, the firm utilized the titration assay method for the accelerated stability studies of (b) (4) API (lot#s(b) (4) The data from the accelerated stability studies was later utilized to determine the shelf life of the product. The firm has no data to support the use of the titration assay method as a stability indicating method or that it has the ability to detect impurities or degradants over the shelf life of the API.
- 3
Incomplete verification of supplier COAs
Verification testing of the raw material supplier COA is inadequate as the firm has failed to conduct all of the analyses listed on the respective supplier COA. For example: The (b) (4) lot# (b) (4) COA from (b) (4) lists the following analyses: appearance, specific gravity, (b) (4) (b) (4) The firm's verification testing of the aforementioned supplier COA only included the following: specific gravity, (b) (4) The (b) (4) lot# (b) (4) COA from (b) (4) lists the following analyses: purity, ignition on residue, moisture, (b) (4) foreign matter. The firm's verification testing of the aforementioned supplier COA only included the following: purity and ignition on residue. The (b) (4) lot (b) (4) COA from (b) (4) lists the following analyses: (b) (4) concentration, (b) (4) specific gravity, (b) (4) and viscosity. The firm's verification testing of the aforementioned supplier COA only included the following: (b) (4) concentration, (b) (4) and specific gravity.
- 4
Inadequate cleaning and maintenance of equipment
Equipment and utensils utilized in the production of API for the US Market are not cleaned or maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, purity and quality of the drug substance. For example: Reddish-brown discoloration was observed on the interior of the water hose to holding vessel (RT-8). The aforementioned hose is utilized in the pumping of water into the ceiling of the vessel to prevent (b) (4) from escaping. The holding vessel is utilized in the manufacturing of (b) (4) API (b) (4) Reddish-brown discoloration was observed on the interior of the water hoses to (b) (4) (GM-5). The aforementioned hoses are utilized in the pumping of water to cool the interior of the vessel. The (b) (4) is utilized in the manufacturing of (b) (4) API (b) (4) White powder residues were observed on the exterior of the Kubota scale within the Line (b) (4) sampling room. The aforementioned scale is utilized in the weighing of critical raw materials used for the manufacturing of (b) (4) (b) (4) API. According to the management team, the scale was reported to have been cleaned; however, the firm does not document any cleaning activities within the sampling room. The firm utilizes a (b) (4) sampling tool during the (b) (4) API (b) (4) manufacturing process. The sampling tool is utilized at various points of the initial process including (b) (4) (b) (4) According to the management team, the sampling tool is reported to be cleaned in-between uses, however, the cleaning of the sampling tool is not documented.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.