Central Glass Co., Ltd. Form 483, September 2023

FDA issued this Form 483 to Central Glass Co., Ltd. in Ube, Japan (FEI 3002806649) at the end of a drug inspection that ended September 15, 2023. It lists 6 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Nov 5, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Sep 15, 2023
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Nov 5, 2026
1,147 days after the inspection
Facility
FEI 3002806649
Ube, Japan

The 6 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Inadequate laboratory controls and standards

    Laboratory Controls are inadequate. Specifically, a) The working standards used during release testing of (b) (4) for assay and volatile analogues not always elude peaks for the corresponding volatile analogues. During qualification of your working standards one of the requirements is to verify the presence of all peaks. However, injection of standard lot (b) (4) during analysis of commercial (b) (4) API lots (b) (4) does not contain peaks for all volatile analogues at their respective retention time. b) Access control to samples that have not been assigned and those for which testing has been completed is not restricted. In addition on 9/11/23 completed samples of released (b) (4) batches (b) (4) [illegible] Your firm noted verbally that the completed samples were not discarded because they will be used to qualify analysts, however there was no documentation to support this. c) Your site does not conduct growth promotion of media used to perform environmental monitoring of the filling room used for (b) (4) API. d) On 9/11/23 I observed a filled GC vial labeled as "extra" unattended in the laboratory near to GC 23 stand alone equipment, when requested for the origin of the vial and content your site could not establish if the vial contained System Suitability (SST) solution, standard, or samples. Your site explained that they believed the vial was filled with System Suitability solution however, there was no documentation for this. e) During the update of software and hardware for system GC-24 the number of theoretical plates was not calculated prior to placing the system back in use.

  2. 2

    Water specs lack B. Cepacia testing

    Specifications of Water used in the manufacture of APIs do not demonstrate the water is suitable for its intended use. Specifically, specifications for water used for cleaning and processing after (b) (4) water and (b) (4) (b) (4) do not include testing to confirm the absence of B. Cepacia from your water system.

  3. 3

    Cleaning procedures not validated

    Your cleaning procedures are not validated. Specifically, a) Your firm has not performed validation of the cleaning procedures used to clean equipment that is used for (b) (4) filling API into containers. (b) (4) varies. For example the (b) (4) however the number of consecutive batches manufactured on the equipment in (b) (4) [illegible] b) (b) (4) batches, however the (b) (4) campaign executed to asses the cleaning re-validation study of 10/15/20 consisted of (b) (4) c) Cleaning validation studies for bulk containers including clean hold time do not include samples to determine appropriate microbial levels. d) Removal of (b) (4) (b) (4) is verified using (b) (4) this method is not used during (b) (4) [illegible] f) (b) (4) sensitive to indicate if (b) (4) is reduced to levels that indicate it has been removed. e) Your test method used from 2015-2020 to evaluate cleaning validation samples had an LOQ of (b) (4) ppm. This test was not suitable for the evaluation of cleaning validation samples (b) (4) specifications for residue were (b) (4) ppm during this time.

  4. 4

    Change control system not followed

    Changes that could affect the production and control of the intermediate or API are not always handled using the formal change control system. Specifically, a) The following changes were not handled using the change control system (list is not exhaustive): Change of AC system in filling room, your firm noted that the reason to not execute a change control for this (b) (4) change was because the AC was being replaced with a unit that met the same specifications. However at the time of the change the comparison between the old and new unit was not documented to justify the lack of change control. On 8/6/23 UQSE20-19 test method used to evaluate rinse samples from cleaning validation was changed to obtain a lower LOD and LOQ the residue limit on equipment was also changed from (b) (4) ppm to (b) (4) ppm. The reason for not performing this change using the change control program was not documented. b) Change control CCQ22-17 enacted to address change in storage of (b) (4) medium used by QC from refrigeration to room temperature states that the firm will verify if the storage conditions change has any impact on tests. However there were no steps, protocol or instructions on how your firm would perform the noted verification. In addition on 9/15/23 I observed that there is no calibrated device to monitor the temperature of the room where the media is stored.

  5. 5

    Validation lacks critical process parameters

    Your validation protocols for the execution of revalidation studies do not specify critical process steps. Your process validation studies for (b) (4) do not show the critical process parameters that were going to be studied, review of batch records shows that the validation study did not include variation of parameters within the established ranges. In addition parameters such as the timer used to control the flow in the (b) (4) are not defined as critical process parameters.

  6. 6

    Inadequate raw material receiving procedures

    Your receiving procedures for raw materials are inadequate. Specifically, You do not have procedures that require proof from your vendor that the tanks used to deliver (b) (4) (b) (4) are properly cleaned between each delivery.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.