FRUEH VERPACKUNGSTECHNIK AG
Allmendstrasse 47, Fehraltorf, Switzerland
FEI 3010363503DUNS 481183416
FDA has 3 inspections on file for FRUEH VERPACKUNGSTECHNIK AG in Fehraltorf, Switzerland (FEI 3010363503), from 2020 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for packing, labeling and analysis, through Dec 31, 2027. Its registrant is Frueh Verpackungstechnik AG (D-U-N-S 481183416).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2020–2025
- 0 OAI · 2 VAI · 1 NAI
- Inspections with 483 observations shown
- 1 of 3
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 1 request, latest Sep 4, 2025
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: DevicesPosted 483 · 6 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Missing cleaning validation and disinfectant efficacy
Procedures for the cleaning and maintenance of equipment are deficient regarding the protection of clean equipment from contamination prior to use. Specifically, your firm has not performed any cleaning validation studies to assess the effectiveness of your cleaning procedures for equipment and rooms used in the packaging operations for (b)(4) drug products. Additionally, no disinfectant efficacy studies have been conducted to ensure the effectiveness of your disinfectants used during cleaning operations.
- Observation 2
Supplier requirements lack bioburden controls
Requirements that must be met by suppliers have not been adequately established. Specifically, components of (b)(4) drug product are not adequately controlled for bioburden levels. Specifications for (b)(4) do not include a bioburden requirement and incoming certificates of conformity do not certify that components meet a bioburden requirement.
Show observations 3 to 6
- Observation 3
Batch records missing significant packaging steps
The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing, processing, and packing. Specifically, during packaging operations of drug product, we observed (b)(4) This practice of (b)(4) is not detailed in your batch record, nor is it described in a procedure.
- Observation 4
Deficient Quality Unit oversight and data integrity
The responsibilities and procedures applicable to the quality unit are not in writing and fully followed. Specifically, Supervisory oversight over quality/production unit operations and laboratory/production electronic system and data is deficient. For Example A. The Quality Unit lacks adequate control over the issuance of production batch records purported to be controlled under your batch issuance procedures. During the inspection, it was observed that copies of official batch records for drug products (b)(4) without adequately controlling each page. For example, (b)(4) B. There are no requirements for the Quality Unit oversight of Master Batch Record storage and copying for use in manufacturing to ensure executed record instructions are accurate reproductions of the master records. Your firm does not maintain adequate master batch records for the above-mentioned drug products. During the inspection, we observed at least two recent deviations where incorrect batch record documents were issued and used by the production unit. C. Your firm does not have adequate Quality Unit oversight of visual inspection qualification test kits and the qualification process for operators performing visual inspection operations during packaging of drug products. For example, per your firm's procedure, the (b)(4) D. There is no adequate data integrity program in place to include an adequate review of all electronic data by the Quality Assurance Unit for standalone and network systems, to ensure completeness, consistency, and accuracy of all laboratory and production equipment electronic data generated by your firm. Specifically, per your firm's procedure, (b)(4) This review process does not appear to be adequate, in that all potential data generated during that specific review period for that product are not reviewed. There is no adequate reconciliation of all generated electronic test and production data during the review process for standalone and network equipment. E. Your firm does not have a written procedure, which include, but not limited to, establishing the requirements for quality agreements, the responsibilities of each party, and the review and approval for the agreements.
- Observation 5
Incoming lots lack distinctive identification codes
Each lot in shipment received was not identified with a distinctive code for each container or grouping of containers for components. Specifically, The firm does not assign unique lot number for each lot in each shipment received for all drug components. Currently, the firm uses the (b)(4)
- Observation 6
Sterilization process not validated for dryness
A process whose results cannot be fully verified by subsequent inspection and test has not been adequately validated. Specifically, the sterilization process (as reported in Document VB 15254) for (b)(4) (b)(4) The validation does not demonstrate that the process can consistently produce dry product.
- NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Sep 4, 2025. It asked for a Form 483.
Inspection ending Mar 24, 2023VAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Sep 4, 2025FDA-FOIA-2025-10561Form 483· 1 of 2 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
FDA drug establishment registration
FDA registration search- Registered operations
- Packing, labeling, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Frueh Verpackungstechnik AGD-U-N-S 481183416
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3010363503 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3010363503. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.