Skip to content

Laurus Synthesis Private Limited

Plot 74b Jawaharlal Nehru Pharma City, Parawada Anakapalli, Visakhapatnam, India

FEI 3011524794DUNS 650882322

Company: LAURUS SYNTHESIS PRIVATE LIMITED · Linked by exact D-U-N-S match (855540302) in FDA registration data

FDA has one inspection on file for Laurus Synthesis Private Limited in Visakhapatnam, India (FEI 3011524794). It ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below.

No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, through Dec 31, 2027. Its registrant, LAURUS SYNTHESIS PRIVATE LIMITED (D-U-N-S 855540302), has registered 1 other site.

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
1, in 2023
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
↗
Requested under FOIA
1 request, latest Jul 26, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate investigations of deviations and OOS

      Investigation of unexpected occurrences are not adequately conducted. Specifically, A. Investigations into damage of (b) (4) which are used in the manufacturing of key starting materials and API intermediates intended for the US market, are inadequate. In the past three years, five deviations involving (b) (4) damage were initiated with three deviations being deficient. For example: 1) Deviation investigations DEV-SV1-22-0002, DEV-SV1-23-0002, and DN/LSV1/MFG/019/21 for (b) (4) damage did not document the size and/or location of the (b) (4) damage. 2) Deviation investigation DEV-SV1-22-0002 was initiated on January 10, 2022 to investigate damage of the (b) (4) (b) (4) of (b) (4) 202. The (b) (4) was observed during batch-to-batch cleaning on January 10, 2022. The damage was not present during preventive maintenance done on November 21, 2021. A total of (b) (4) batches were manufactured since the last Preventive Maintenance, including (b) (4) batches of (b) (4) (b) (4) and (b) (4) batches of (b) (4) (b) (4). The investigation did not include screening all (b) (4) batches for (b) (4) particles. Only (b) (4) lots of product (b) (4) manufactured after product changeover were sampled and inspected for (b) (4) particles by filtration. The complete bulk lot was not visually inspected for particles and there was no scientific rationale for taking (b) (4) g of sample from a (b) (4) bulk batch for screening for (b) (4) particles. The key starting material (b) (4) is used in the manufacture of API (b) (4) intended for the US and Global markets. 3) Deviation investigation DEV-SV1-23-0002 was initiated on January 07, 2023 to investigate damage of the (b) (4) (b) (4) on the (b) (4) 221. The damage was observed during Preventive Maintenance done on January 07, 2023. The damage was not identified during product change over cleaning on January 05, 2023 and during prior Preventive Maintenance on October 07, 2022. A total of (b) (4) lots of (b) (4) were manufactured since the last passing Preventive Maintenance on October 07, 2022 and were likely impacted. The investigation stated that there was no impact on the executed batches (b) (4) as they met specification and were consumed in the subsequent stage (b) (4). The investigation did not include screening of any of these batches for (b) (4) particles. These batches were further processed and dispatched. The customer (b) (4) was not informed about the deviation. 4) Deviation investigation for damaged (b) (4) including DN/LSV1/MFG/019/21 (for (b) (4) 05) and DEV-SV1-23-0002 (for (b) (4) 221) were inadequate in tracking (b) (4) particle contaminants. It was stated that there was no impact to products manufactured due to downstream filtration steps that could remove (b) (4) particles. However, the capability of the filtration steps to remove (b) (4) particles was not scientifically justified, proven, or documented within the investigation report. B. Non-Conformance Investigation NCM/LSV1/003/22 was initiated for non-conforming assay and purity results by HPLC during (b) (4) hold-time study of key starting material (b) (4). One out of (b) (4) batches on hold time study (2 of (b) (4) samples) analyzed failed for assay and impurities. The investigation concluded that it was an isolated case and no further actions were documented. C. OOS investigation OOS/LSV1/001/22 identified improper in-process sampling as suspected cause for impurity by HPLC for key starting material (b) (4). The investigation infers that the operator collected samples only from the (b) (4) in process material and therefore the assay passed during in-process testing and failed for impurity during finished testing. However, procedure MFG/027, "In-process sampling", does not specify the correct sampling procedure to account for (b) (4) in-process materials. In addition, the (b) (4) material within the (b) (4) was not scientifically justified or proven. D. Non-Conformance Investigation NCM-LSV1-001 was initiated for OOS results for (b)

      Shortened here; the PDF has the full text.

    2. Observation 2

      Non-representative intermediate sampling plan

      Sampling plans for intermediates are inadequate. Specifically, The current sampling plan for the intermediate (b) (4) fails to ensure that a representative sample is obtained for assay and impurities. (b) (4) is (b) (4) which is then (b) (4) (b) (4). After (b) (4) the product is packaged and a (b) (4) sample is taken from each drum of packaged intermediate and analyzed for loss on drying, assay, and impurities. Although (b) (4) validation (b) (4) SV1/(b) (4) has been performed to assess the uniformity of (b) (4) for (b) (4), the critical quality attributes of assay and impurities were not assessed in any study to ensure that these quality attributes are also uniformly distributed within the material and therefore the sample is representative of the batch.

    Show observations 3 to 5
    1. Observation 3

      Equipment cleaning maintenance and storage deficiencies

      Equipment is not maintained, cleaned, and stored in a manner to prevent contamination. Specifically, During the walkthrough of (b) (4) on December 04-05, 2023, the following were observed related to the equipment used in the manufacturing of API intermediate (b) (4): A. The interior of (b) (4) 104 and (b) (4) 109, which are used during the manufacture of (b) (4) had apparent rust on the (b) (4). Furthermore, (b) (4) (b) (4) 116, which is also used in the manufacturing of (b) (4) had apparent product residue remaining in the (b) (4) even though the (b) (4) was identified as cleaned. B. (b) (4) 201 used in the (b) (4) had apparent white residue contained on and around the (b) (4). In addition, outside light was observed from the inside of the (b) (4) (b) (4) room where product is final packaged through gaps surrounding the (b) (4). Furthermore, the (b) (4) covering the (b) (4) had apparent dirt and dark residue embedded on the (b) (4) (b) (4). This (b) (4) was stated to have been inspected as clean on December 02, 2023 during the (b) (4) preventive maintenance. C. Product contact transfer hoses used to transfer (b) (4) during production and non-product contact transfer hoses are stored in the accessory room on a shelf with the hose ends covered with bags. These hoses were not stored in a way to ensure that any residual solvent or moisture after use and cleaning does not remain within the hoses. In addition, debris were found in at least two of the hoses that were identified as clean in the area. Furthermore, these hoses do not have an associated equipment ID nor did all hoses have an associated cleaning tag attached.

    2. Observation 4

      Incomplete batch production records

      Batch production records do not contain complete information related to the production and control of the batch. Specifically, A. Portable gauges, such as the (b) (4) used to (b) (4) process water, and product and non-product contact transfer hoses are not identified or recorded within the batch production record for traceability and to ensure they are adequate for use. B. The use of process water in the manufacture of (b) (4) is not adequately documented, including the required performance of the sample port and transfer hose (b) (4) prior to use according to procedure MFG/024 (b) (4) of Materials into (b) (4). C. (b) (4) pressure is applied and maintained up to (b) (4) cm2 to the (b) (4) during the (b) (4). The pressure reading during these steps is not recorded even though your manufacturing personnel stated that the gauge has a numeric reading.

    3. Observation 5

      Uncontrolled issuance of batch record pages

      The issuance of documents is not adequately controlled. Specifically, Batch product record annexure pages that contain batch-related information and data are not adequately issued and controlled. For example, during the manufacture of (b) (4) batches (b) (4) (b) (4), five, six, and five annexure pages, respectively, were used in the manufacture to document weights obtained during (b) (4). These pages are printed by production personnel as outlined in procedure QA/086, "Procedure for Operation of Document Management System (DMS) Software", and can be used for any purpose as part of the execution of the batch record. These pages are not issued, controlled, or reconciled in a way to ensure that the data and records are complete and that all pages printed are accounted for as part of batch record execution and documentation.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Jul 26, 2026. It asked for a Form 483.

  • Inspection ending Jan 1, 2021

    1 request. Not listed in FDA’s Data Dashboard yet. None of FDA’s log entries for these requests say records were released.

    1. Jul 26, 2026FDA-FOIA-2026-7171Form 483 + EIRWithdrawn

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing
Registration runs through
Dec 31, 2027
Registrant
LAURUS SYNTHESIS PRIVATE LIMITEDD-U-N-S 855540302

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names LAURUS SYNTHESIS PRIVATE LIMITED (D-U-N-S 855540302) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

  • LAURUS SYNTHESIS PRIVATE LIMITEDAndhra Pradesh, India · FEI 3030127492Registered; no FDA inspection on file

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3011524794 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3011524794. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.