Batch records and documentation in FDA Form 483 observations
Master and batch production records, device history records, logbooks and good documentation practice. FDAgent finds 241 such observations in 143 Form 483s issued to 137 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 241
- Each quoted below
- Form 483s
- 143
- Posted by FDA
- Facilities
- 137
- Distinct FEIs
- Most recent
- Sep 28, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 80 in 2026
| Year | Observations |
|---|---|
| 2008 | 3 |
| 2009 | 0 |
| 2010 | 1 |
| 2011 | 0 |
| 2012 | 4 |
| 2013 | 4 |
| 2014 | 0 |
| 2015 | 3 |
| 2016 | 16 |
| 2017 | 12 |
| 2018 | 15 |
| 2019 | 13 |
| 2020 | 0 |
| 2021 | 7 |
| 2022 | 18 |
| 2023 | 22 |
| 2024 | 15 |
| 2025 | 28 |
| 2026 | 80 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
21 CFR 211.18021 CFR 211.18421 CFR 211.18621 CFR 211.18821 CFR 820.18121 CFR 820.184
A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“batch record*” · “batch production … record*” · “master production … record*” · “master batch record*” · “device history record*” · “device master record*” · “documentation practice*” · “logbook*” · “log book*” · “BPR*” · “MPR*” · “BMR*”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 241 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Eugia Steriles Private LimitedInspection ended Jun 19, 2026 · FEI 3027357163 · Observation 3
… However, according to the batch record checklist for review of Batch No. (b)(4) Sr. No 25, Work orders/Maintenance request if any is closed. Result: No. There is no written justification as to why the open work order was not referenced in the batch record. C. There is no standard operating procedure or written justification for the following trials captured in the audit trail for (b)(4) vial liquid (b)(4) product filling and stoppering machine in …
Contains “batch record*”Read the Form 483 →
TOYO Pharmaceutical Co., Ltd.Inspection ended Jun 12, 2026 · FEI 3016419927 · Observation 2
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, Your firm does not have unique usernames and passwords for each operator using electronic systems in production. Your firm only has one login password for each of the following production equipment using electronic systems for setting …
Contains “master production … record*”Read the Form 483 →
Annovex Pharma IncInspection ended Jun 3, 2026 · FEI 3020928491 · Observation 2
Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures. Specifically, your firm has not conducted annual product reviews for any drug product in your portfolio. Your Quality Assurance Manager confirmed that no annual product reviews have been completed and that the standard …
Opens with FDA's citation wording for 21 CFR 211.180(e)Read the Form 483 →
PQ Pharmacy LLCInspection ended Jun 1, 2026 · FEI 3017374013 · Observation 4
… 0.09% PF, Lot PMB121525CH BUD 12/15/2026, two (2) consecutive tests resulted in the error message "Error: (b)(4) Not Obtainable"; neither were recorded in the batch record, subjected to (b)(4) (b)(4) operations review, or reviewed by your quality unit. B) Procedure S403400, "Use and Maintenance of (b)(4)" Version 3, dated 12SEP2025, does not address "error" results and provides no instruction for their documentation, escalation, or investigation. …
Contains “batch record*”Read the Form 483 →
Nippon Kayaku Co., LtdInspection ended May 29, 2026 · FEI 3002807722 · Observation 1
Supervisory oversight over the laboratory electronic systems and data is deficient. Specifically, A. Your firm does not reconcile official GMP documents issued from your ArcSuite Engineering document management system. Your firm uses ArcSuite Engineering to issue test records used for GMP testing and to issue manufacturing batch records. You stated the documents are approved by QA in the electronic system prior to printing out, but your firm does …
Contains “batch record*”Read the Form 483 →
Shilpa Medicare LimitedInspection ended May 29, 2026 · FEI 3018694237 · Observation 4
Production records do not contain complete information relating to the production and control of each batch. You failed to document in your batch packing record (BPR # for (b) (4) (b) (4) (b) (4) the total number of rejects (b) (4) collected from the system and checkweigher rejected, and the number of rejects actually (b) (4) (b) (4) displayed from the system and the checkweigher display for reconciliation. In addition, when (b) (4) collected …
Contains “BPR*”Read the Form 483 →
Shilpa Medicare LimitedInspection ended May 29, 2026 · FEI 3018694237 · Observation 5
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, Per your Production Manager (b) (6) your firm does not review data, audit trails and alarm reports generated by the HMIs (GT-2708) and SCADA of your non-dedicated equipment ID #PR-E016) (b) (4) and (ID #MB-E030) utilized in the Micro …
Contains “master production … record*”Read the Form 483 →
PETNET Solutions Inc.Inspection ended May 22, 2026 · FEI 3036193770 · Observation 3
Your master production and control records did not include a statement of action limits on radiochemical yield. Specifically, A. The manufacturing batch records for (b) (4) Injection do not include action limits on radiochemical yield. For example, Manufacturing batch record for PPQ batch # (b) (4) on page 3 of 26 Section, Final Product Vial Assay and Sterility Inoculations, the radiochemical yield is only recorded, however, there is no statement …
Contains “master production … record*”Read the Form 483 →
Shanghai AmbioPharm, Inc.Inspection ended May 22, 2026 · FEI 3006494603 · Observation 3
Master production records lack complete manufacturing and control instructions. Specifically, A. During the review of the qualification document, "Validation Protocol/Report, [illegible] Re-Validation Protocol/Report (SE.400), SE.400-2019-02, Effective Date: 04/12/2019, I observed the [illegible] qualification was performed at [illegible] However, during the review of the batch record for Batch No: (b)(4) I observed the actual (b)(4) and (b)(4) …
Contains “master production … record*”Read the Form 483 →
Shanghai Henlius Biopharmaceutical Co., Ltd.Inspection ended May 20, 2026 · FEI 3016529861 · Observation 11
Your firm failed to investigate a laboratory sample handling error in a timely manner. Specifically, on May 4, 2026, batch record (b)(4) recorded that an operator used a wrong sample to perform (b)(4) testing at Step (b)(4) of the (b)(4) production bioreactor operation for (b)(4) drug substance batch (b)(4) and generated result (b)(4) which was not related to batch (b)(4) but saved with the actual IPC test results (b)(4). No deviation was …
Contains “batch record*”Read the Form 483 →
LGM Pharma Solutions, LLCInspection ended May 18, 2026 · FEI 3017140477 · Observation 1
… The batch record lists hardness and thickness limits as "Record Only," providing no enforceable in-process trigger to detect or respond to compression drift during tableting.
Contains “batch record*”Read the Form 483 →
Jiangsu Hansoh Pharmaceutical Group Co Ltd.Inspection ended Apr 24, 2026 · FEI 3008316144 · Observation 1
… In the batch record, there is no differentiation between the main operator and the support operators. Media fills are handled the same way with no way to determine who the support operators were verses who performed the aseptic connection. This results in no assurance that an operator performing setup in commercial manufacturing previously performed a successful setup in a media fill. E. The sterilization processes used for equipment that comes …
Contains “batch record*”Read the Form 483 →
USV Private LimitedInspection ended Apr 17, 2026 · FEI 3004086192 · Observation 4
… Review of the firm's logbook showed inspectors took an average (b) (4) to inspect (b) (4) containers during their (b) (4) qualifications, providing only (b) (4) per container total (b) (4) (b) (4)
Contains “logbook*”Read the Form 483 →
Cliantha Research LimitedInspection ended Apr 17, 2026 · FEI 3017682080 · Observation 2
… and Set III samples Set II subject samples and QCs Set II subject samples and QCs Sample movement details were subsequently transposed from the scrap paper to logbooks for freezers FDI-53 and FDI-27, and thus the logbooks are not the contemporaneous source documents. Add Continuation Page b. Partial details of samples transferred from freezer FDI-10 to freezer FDI-44 were recorded on a scrap piece of paper found in the trashcan of the first-floor …
Contains “logbook*”Read the Form 483 →
Cliantha Research LimitedInspection ended Apr 17, 2026 · FEI 3017682080 · Observation 4
4. The firm reported inaccurate data in the bioanalytical report for study (b) (4) (b) (4). Specifically, Section 5.1.2 of the report stated that aliquot 2 samples were not used in sample analysis. However, the logbook for freezer FWI-06 (A-AL-25-503) documented retrieval of aliquot 2 samples from subjects (b) (6) and (b) (6) on 07 Oct 2025 for use in ISR analysis and subsequent return of the samples on the same date. Add Continuation Page
Contains “logbook*”Read the Form 483 →
Lonza Biologics, Inc.Inspection ended Apr 16, 2026 · FEI 3001451441 · Observation 2
… b) DEV-1435080 was initiated on 10/29/2025 after a trend was identified for EM good documentation practices (GDP) assay errors and incorrect performance of critical in operation (CIO) EM. CAPA-1447250 was opened on 11/18/2025 to include an action plan for initiation of a (b)(4) for establishment of a (b)(4) SOP for (b)(4) and training guidelines. However, a (b)(4) has yet to be initiated for development and implementation of a (b)(4) SOP and …
Contains “documentation practice*”Read the Form 483 →
Jiangsu Hengrui PharmaceuticalsInspection ended Apr 15, 2026 · FEI 3006689263 · Observation 2
… performed (b)(4) integrity testing with the time between a finished test of a (b)(4) and the start of a new (b)(4) test to be no less than (b)(4) However, the batch records show (b)(4) integrity testing time between finish of a test and start of a new test to be between (b)(4) Your firm then provided a video proving the operators could work even faster, completing the (b)(4) integrity test, and starting a test in less than (b)(4) During this …
Contains “batch record*”Read the Form 483 →
ChemPacific CorporationInspection ended Apr 7, 2026 · FEI 3003299802 · Observation 1
… For example, analysts conducted sample testing without recording the activities in laboratory logbooks and analyst notebooks. The undocumented analyses fall into the following categories with the reasoning behind each injection: [illegible table - claimed purpose, material, injections, date, category including system suitability, condition check, analysis, testing, column check entries dated 04/23/2023, 04/27/2023, 08/16/2023, 08/28/2023, …
Contains “logbook*”Read the Form 483 →
Conroe Welding Supply, IncInspection ended Apr 3, 2026 · FEI 1625647 · Observation 1
… It was observed on batch records that the filler, tester, and product release approver were the same person, demonstrating a lack of independent verification and segregation of duties, as shown on batch records dated (b) (4) (lot (b) (4)), (b) (4) (lots (b) (4)), (b) (4) (lot (b) (4)), (b) (4) (lots (b) (4) (b) (4)), and (b) (4) (lots (b) (4)). Your firm distributed these lots to customers. C. Your firm failed to provide cGMP training to …
Contains “batch record*”Read the Form 483 →
Conroe Welding Supply, IncInspection ended Apr 3, 2026 · FEI 1625647 · Observation 2
Batch production records do not include documentation that each significant step in the packaging of the medical gas was performed. Specifically, Source bulk (b) (4) lot numbers were not recorded on batch records dated (b) (4) (lots (b) (4)), (b) (4) (lots (b) (4)), and (b) (4) (lots (b) (4)). These lots were distributed to customers.
Contains “batch production … record*”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.188Batch production and control recordsIn this theme's rule17
- 21 CFR 211.100Written procedures; deviations14
- 21 CFR 211.22Responsibilities of quality control unit13
- 21 CFR 211.68Automatic, mechanical, and electronic equipment13
- 21 CFR 211.113Control of microbiological contamination11
- 21 CFR 211.180General requirementsIn this theme's rule8
- 21 CFR 211.186Master production and control recordsIn this theme's rule5
- 21 CFR 211.42Design and construction features4
- 21 CFR 211.160General requirements4
- 21 CFR 211.192Production record review4
Ask FDAgent about batch records and documentation in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.