Shanghai AmbioPharm, Inc. Form 483, May 2026
FDA issued this Form 483 to Shanghai AmbioPharm, Inc. in China (FEI 3006494603) at the end of an inspection that ended May 22, 2026. It lists 3 observations.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 17, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- May 22, 2026
- —
- FDA's outcome
- Not classified
- Not classified yet
- Posted by FDA
- Nov 17, 2026
- 179 days after the inspection
The 3 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Quality control unit procedures not written/followed
The responsibilities and procedures applicable to the quality control unit are not in writing or fully followed. Specifically, Your firm utilizes third-party testing from multiple contract testing laboratories. Your firm has not established a Quality Agreement with the third-party laboratories or provided approval for any subcontracted testing not performed by your headquarters.
- 2
Equipment not qualified, uncontrolled transfers, leak
Equipment used in the manufacturing, processing, packing or holding of drug products is not installed, qualified, maintained and/or suitably located to facilitate operations for its use. Specifically, A. Equipment identified as being used in the manufacturing of exhibit batches, post-exhibit batches, and [illegible] commercial manufacturing of [illegible] Solution (DMF [illegible]) is not currently installed, qualified, or demonstrated to be suitable for its use. For example, the following impacted equipment [illegible] drug product for the U.S. market. [illegible] used during the manufacturing of the [illegible] B. Additionally, I observed equipment (i.e., [illegible]) is transferred between different manufacturing rooms and/or buildings. However, your firm does not initiate any change controls and there has been no risk assessment to support the transfer of equipment and evaluate potential effects on [illegible] product quality, facility suitability, qualification status, and [illegible] C. During the walkthrough of the [illegible] system on 05/18/2026 in Building [illegible] observed [illegible] leaking from the connection point between the [illegible] pipe and the attachment associated with the utility system.
- 3
Master batch records lack complete parameters
Master production records lack complete manufacturing and control instructions. Specifically, A. During the review of the qualification document, "Validation Protocol/Report, [illegible] Re-Validation Protocol/Report (SE.400), SE.400-2019-02, Effective Date: 04/12/2019, I observed the [illegible] qualification was performed at [illegible] However, during the review of the batch record for Batch No: (b)(4) I observed the actual (b)(4) and (b)(4) parameters are not recorded. B. During the review of the qualification document, [illegible] Requalification Report", Effective Date: 06/27/2025, I observed the assessed [illegible] during the qualification were [illegible] However, during the review of the batch record for Batch No: [illegible] I observed the actual (b)(4) and (b)(4) parameters are not recorded.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.