FDA has 3 inspections on file for Shanghai AmbioPharm, Inc. in China (FEI 3006494603), from 2013 to 2026. The latest ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below. One FOIA request has asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing and analysis, through Dec 31, 2026. Its registrant is Shanghai Ambiopharm, Inc (D-U-N-S 529125699).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 3, 2013–2026
- 0 OAI · 1 VAI · 1 NAI
- Inspections with 483 observations shown
- 1 of 3
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 1 request, latest Jul 20, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- Not classified yetClassification not posted yetPosted 483 · 3 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Quality control unit procedures not written/followed
The responsibilities and procedures applicable to the quality control unit are not in writing or fully followed. Specifically, Your firm utilizes third-party testing from multiple contract testing laboratories. Your firm has not established a Quality Agreement with the third-party laboratories or provided approval for any subcontracted testing not performed by your headquarters.
- Observation 2
Equipment not qualified, uncontrolled transfers, leak
Equipment used in the manufacturing, processing, packing or holding of drug products is not installed, qualified, maintained and/or suitably located to facilitate operations for its use. Specifically, A. Equipment identified as being used in the manufacturing of exhibit batches, post-exhibit batches, and [illegible] commercial manufacturing of [illegible] Solution (DMF [illegible]) is not currently installed, qualified, or demonstrated to be suitable for its use. For example, the following impacted equipment [illegible] drug product for the U.S. market. [illegible] used during the manufacturing of the [illegible] B. Additionally, I observed equipment (i.e., [illegible]) is transferred between different manufacturing rooms and/or buildings. However, your firm does not initiate any change controls and there has been no risk assessment to support the transfer of equipment and evaluate potential effects on [illegible] product quality, facility suitability, qualification status, and [illegible] C. During the walkthrough of the [illegible] system on 05/18/2026 in Building [illegible] observed [illegible] leaking from the connection point between the [illegible] pipe and the attachment associated with the utility system.
Show observation 3
- Observation 3
Master batch records lack complete parameters
Master production records lack complete manufacturing and control instructions. Specifically, A. During the review of the qualification document, "Validation Protocol/Report, [illegible] Re-Validation Protocol/Report (SE.400), SE.400-2019-02, Effective Date: 04/12/2019, I observed the [illegible] qualification was performed at [illegible] However, during the review of the batch record for Batch No: (b)(4) I observed the actual (b)(4) and (b)(4) parameters are not recorded. B. During the review of the qualification document, [illegible] Requalification Report", Effective Date: 06/27/2025, I observed the assessed [illegible] during the qualification were [illegible] However, during the review of the batch record for Batch No: [illegible] I observed the actual (b)(4) and (b)(4) parameters are not recorded.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Jul 20, 2026. It asked for a Form 483.
Inspection ending May 22, 2026Not classified yet
1 request. In the inspection history above. FDA has posted its Form 483.
- Jul 20, 2026FDA-FOIA-2026-6893Form 483 + EIRRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing, analysis
- Registration runs through
- Dec 31, 2026
- Registrant
- Shanghai Ambiopharm, IncD-U-N-S 529125699
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3006494603 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3006494603. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.