Batch records and documentation in FDA Form 483 observations
Master and batch production records, device history records, logbooks and good documentation practice. FDAgent finds 241 such observations in 143 Form 483s issued to 137 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 241
- Each quoted below
- Form 483s
- 143
- Posted by FDA
- Facilities
- 137
- Distinct FEIs
- Most recent
- Sep 28, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 80 in 2026
| Year | Observations |
|---|---|
| 2008 | 3 |
| 2009 | 0 |
| 2010 | 1 |
| 2011 | 0 |
| 2012 | 4 |
| 2013 | 4 |
| 2014 | 0 |
| 2015 | 3 |
| 2016 | 16 |
| 2017 | 12 |
| 2018 | 15 |
| 2019 | 13 |
| 2020 | 0 |
| 2021 | 7 |
| 2022 | 18 |
| 2023 | 22 |
| 2024 | 15 |
| 2025 | 28 |
| 2026 | 80 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
21 CFR 211.18021 CFR 211.18421 CFR 211.18621 CFR 211.18821 CFR 820.18121 CFR 820.184
A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“batch record*” · “batch production … record*” · “master production … record*” · “master batch record*” · “device history record*” · “device master record*” · “documentation practice*” · “logbook*” · “log book*” · “BPR*” · “MPR*” · “BMR*”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 241 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Centrient Pharmaceuticals India Private LimitedInspection ended Jan 27, 2026 · FEI 3004497364 · Observation 1
… According to the logbook and the cleaning records, (b)(4) was completed on 18-Jan-2026; however, the presence of visible residues demonstrated that the cleaning procedure was ineffective in achieving the required cleanliness for pharmaceutical manufacturing equipment used in multi-product operations. The previous product manufactured was (b)(4) Upon request, your firm conducted a swab analysis and reported the presence of (b)(4) on the (b)(4) …
Contains “logbook*”Read the Form 483 →
Neeyaan LLCInspection ended Jan 27, 2026 · FEI 3024366553 · Observation 4
… The compression operation was not accompanied with a batch production record and there was no documentation indicating that sticking or breaking issues occurred during compression of this batch. Additionally, no formal investigation was initiated to assess the potential impact on product quality or to identify root causes of the sticking and breaking. B) Annual Product Quality Reviews (PQRs) have not been performed in accordance with section 5.2 …
Contains “batch production … record*”Read the Form 483 →
Neeyaan LLCInspection ended Jan 27, 2026 · FEI 3024366553 · Observation 5
… In addition, the firm does not maintain a Retain Sample Logbook or a record of the inventory of retain samples as required by section 5.10 of SOP-46. Furthermore, section 5.11 of SOP-46 requires that retain samples be stored in a designated, secure, and climate-controlled storage area; however, on 01/21/2026, we observed the retain sample of (b) (4), USP ((b) (4) Tablet) Lot #(b) (4) was stored in the warehouse which is not secured and which …
Contains “logbook*”Read the Form 483 →
Neeyaan LLCInspection ended Jan 27, 2026 · FEI 3024366553 · Observation 6
… B) On 01/14/2026, our observation of tablet compression for (b) (4) Lot #(b) (4) revealed a lack of batch records on the production floor to ensure consistent batch manufacturing and contemporaneous documentation of production activities. Upon request of the blending and compression batch records for (b) (4) Lot #(b) (4), the Blending Operator provided incomplete batch records which did not include any batch identification, preventing …
Contains “batch record*”Read the Form 483 →
Neeyaan LLCInspection ended Jan 27, 2026 · FEI 3024366553 · Observation 8
Batch production and control records do not include the specific identification of each batch of component and in-process material used for each batch of drug product produced. Specifically, The batch records for OTC drug product (b) (4), USP ((b) (4) Tablet) Lot #(b) (4) and Lot #(b) (4) do not include the distinctive lot identification of the raw material (active pharmaceutical ingredients and excipients) used in the manufacturing of the drug …
Opens with FDA's citation wording for 21 CFR 211.188(b)(3)Read the Form 483 →
Neeyaan LLCInspection ended Jan 27, 2026 · FEI 3024366553 · Observation 10
… On 01/09/2026, the (b) (4) for OTC drug product (b) (4) (no lot number was listed in the usage and cleaning logbook) was blended in Mixing Machine (b) (4) following the blending of dietary supplement (b) (4) on the same equipment. B) Usage and cleaning are not always documented in the usage and cleaning logbooks for each equipment used to manufacture and/or package OTC drug products. Additionally, your firm uses a cleaning solution prepared with …
Contains “logbook*”Read the Form 483 →
Neeyaan LLCInspection ended Jan 27, 2026 · FEI 3024366553 · Observation 15
… B) Batch production records for OTC drug products, including but not limited to (b) (4) tablet Lot #(b) (4), (b) (4) tablet Lot #(b) (4) and (b) (4) tablet Lot #(b) (4), lacked the following documentation: Packaging and label reconciliation to ensure accountability of materials used in packaging and labeling operations. Examination of packaging and labeling materials prior to packaging operations. Lot numbers of packaging materials used in …
Contains “batch production … record*”Read the Form 483 →
Neeyaan LLCInspection ended Jan 27, 2026 · FEI 3024366553 · Observation 16
Your batch production record did not include all required information. Specifically, You manufactured (b) (4) Tablet, Batch No #: (b) (4), which was distributed on 4/30/25. The following was observed: The batch manufacturing record was not reviewed and signed off as closed. The master batch packaging record was not completed in its entirety and not reviewed and approved by QA. In addition, the following was observed regarding (b) (4) Capsule, …
Contains “batch production … record*”Read the Form 483 →
Neeyaan LLCInspection ended Jan 27, 2026 · FEI 3024366553 · Observation 17
Your batch production record did not include complete information relating to the production and control of each batch. Specifically, Your written standard operating procedure SOP No. 28 titled "Batch Manufacturing Record" states that a list of raw materials used in the batch, including their sources, batch or lot numbers, and quantities would be included in the batch manufacturing record. However, the following was observed: (b) (4), and (b) (4) …
Contains “batch production … record*”Read the Form 483 →
Neeyaan LLCInspection ended Jan 27, 2026 · FEI 3024366553 · Observation 21
… packaging, and labeling procedures and specifications; satisfactory test results and inspection findings; and completed and approved documentation, including batch records and investigation reports. However, your certificate of analysis for (b) (4) Tablet, Batch No #: (b) (4) was signed as approved on 05/22/2025, which is after the distribution date of 4/30/25. In addition, your certificate of analysis for (b) (4) Capsule, Batch No #: (b) (4) was …
Contains “batch record*”Read the Form 483 →
Neeyaan LLCInspection ended Jan 27, 2026 · FEI 3024366553 · Observation 22
… However, there is no documentation in your Out of Specification Logbook or Deviation Logbook.
Contains “logbook*”Read the Form 483 →
Neeyaan LLCInspection ended Jan 27, 2026 · FEI 3024366553 · Observation 23
You did not establish product specifications for identity. Specifically, You manufactured (b) (4) Tablet, Batch No #: (b) (4), which was distributed on 4/30/25. Your finished dietary supplement product specification for identity lists (b) (4) as the method reference. The method states "Assay results are derived from the batch manufacturing record (BMR) as part of production and process control." This is not a scientifically valid method.
Contains “BMR*”Read the Form 483 →
Shimoga ChemicalsInspection ended Jan 23, 2026 · FEI 3033881432 · Observation 1
… injections prior to or after the official reported sample injections for Related Substances and Assay by HPLC testing that were not documented in laboratory batch records. API batches involved included batch numbers (b)(4). Batches (b)(4) were approved by QA and shipped to the U.S. market. During the current inspection we requested your firm to perform calculations for all unreported Related Substances and Assay injections, where at least one …
Contains “batch record*”Read the Form 483 →
Shimoga ChemicalsInspection ended Jan 23, 2026 · FEI 3033881432 · Observation 2
… Your firm's process validation does not clearly identify the batch records used, their execution sequence, or how records are (b)(4) during the manufacture of (b)(4) USP API and (b)(4), a key starting material. For example, each (b)(4) USP API batch produced following (b)(4) manufacture was a practice not addressed in the process validation documentation. In addition, production occurs through the (b)(4) batch records - manufacture of (b)(4) …
Contains “batch record*”Read the Form 483 →
Shimoga ChemicalsInspection ended Jan 23, 2026 · FEI 3033881432 · Observation 3
Batch production and control records do not include complete information relating to the production and control of each batch. Specifically, A. Your firm fails to maintain accurate and consistent cleaning logs and batch records, demonstrating significant data integrity deficiencies in the documentation of (b)(4) 001 cleaning and (b)(4) of (b)(4) USP API. Review of the following batch (b)(4) batches for (b)(4) reveal discrepancies in cleaning …
Opens with FDA's citation wording for 21 CFR 211.188Read the Form 483 →
Shimoga ChemicalsInspection ended Jan 23, 2026 · FEI 3033881432 · Observation 4
… Your firm's cleaning procedures and batch records do not specify cleaning methods or techniques, materials used, contact times, acceptance criteria, or verification requirements. For example, while the SOPs for the (b)(4) indicate that (b)(4) water/solvent is used for cleaning, the firm stated that they use only (b)(4) water for all equipment cleaning, without differentiation by product, batch, or stage of manufacture. The firm confirmed that the …
Contains “batch record*”Read the Form 483 →
Shimoga ChemicalsInspection ended Jan 23, 2026 · FEI 3033881432 · Observation 5
… 2015 stability study reports and recorded results, we observed that your firm did not have supporting raw test data, both electronic and physical laboratory batch records, for stated results for the long-term (b)(4) stability study. Furthermore, the current ongoing long-term stability study has been performed up to (b)(4) with (b)(4) slated to be tested around (b)(4). Your firm has shipped approximately (b)(4) batches of (b)(4) to the U.S. market …
Contains “batch record*”Read the Form 483 →
Shimoga ChemicalsInspection ended Jan 23, 2026 · FEI 3033881432 · Observation 10
… from 2016 were available for the operator who (b)(4) batch (b)(4); training records for equipment did not include the (b)(4), despite the operator signing batch record (b)(4) for (b)(4) operations using this equipment.
Contains “batch record*”Read the Form 483 →
Genzyme Ireland LimitedInspection ended Jan 20, 2026 · FEI 3003809840 · Observation 1
Laboratory records are deficient in that they do not include a complete record of all data obtained during testing. Specifically, deficiencies in documentation and data integrity were identified in environmental monitoring and (b) (4) testing records. The records and data for these quality control activities do not demonstrate adequate integrity controls and documentation practices. A) Failing non-viable particulate testing data present in the …
Contains “documentation practice*”Read the Form 483 →
Genzyme Ireland LimitedInspection ended Jan 20, 2026 · FEI 3003809840 · Observation 2
… QE-152679 (initiated July 1, 2025): Cancelled for missing logbook entries based on "presence of a second GMP source". QE-134066 (initiated March 27, 2025): Cancelled for incorrect (b) (4) confirmed from original GMP source with manufacturing and QA agreement. QE-094631 (initiated November 17, 2024): Cancelled as "raised in error, no longer required and can be voided" with original deviation description overwritten. QE-090910 (initiated November …
Contains “logbook*”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.188Batch production and control recordsIn this theme's rule17
- 21 CFR 211.100Written procedures; deviations14
- 21 CFR 211.22Responsibilities of quality control unit13
- 21 CFR 211.68Automatic, mechanical, and electronic equipment13
- 21 CFR 211.113Control of microbiological contamination11
- 21 CFR 211.180General requirementsIn this theme's rule8
- 21 CFR 211.186Master production and control recordsIn this theme's rule5
- 21 CFR 211.42Design and construction features4
- 21 CFR 211.160General requirements4
- 21 CFR 211.192Production record review4
Ask FDAgent about batch records and documentation in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.