Skip to content

Centrient Pharmaceuticals India Private Limited

Bhai Mohan Singh Nagar, Village Toansa, District Sbs Nagar, Nawashahr, India

FEI 3004497364DUNS 860184986

Company: Centrient Pharmaceuticals Netherlands B.V. · Linked by exact D-U-N-S match (409002560) in FDA registration data

FDA has 4 inspections on file for Centrient Pharmaceuticals India Private Limited in Nawashahr, India (FEI 3004497364), from 2015 to 2026. The latest ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below. Three of the six FOIA requests for this site have asked FDA for this inspection's 483.

FDA issued a warning letter on (CDER). 2 import refusals are filed under this FEI, the latest on . FDA’s Import Alert 66-40 Red List names this firm at this address. FDA printed no FEI on the entry. No court action is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, through Dec 31, 2027. Its registrant, Centrient Pharmaceuticals Netherlands B.V. (D-U-N-S 409002560), has registered 3 other sites.

Sources:FDA firm profile ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
4, 2015–2026
3 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
1 of 4
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
Requested under FOIA
6 requests, latest FY2023
Import refusals
2 refusals
Import alerts
66-40Red List
Matched on FDA’s firm name and street address
Drug establishment registration
Through

Inspection history

4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance3 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Failure to clean non-dedicated equipment

      Failure to clean equipment and utensils to prevent contamination or carry-over of a material that would alter the quality of the intermediates and Active Pharmaceutical Ingredient beyond the official or other established specifications. Specifically, The (b)(4) used at the (b)(4) stages of APIs manufacturing have not been non-dedicated (b)(4) appropriately cleaned since their installation 27+ years ago. For example, A. On 19 and 20 January 2026, we observed thick build-up of (b)(4) materials of (b)(4) (b)(4) on the (b)(4) Ducts of IDs: (b)(4) (b)(4) These non-dedicated [equipment] located in your (b)(4) facility - Site (b)(4) (b)(4) are used in the manufacturing of APIs. During the inspection, these (b)(4) were in use for (b)(4) manufacturing of (b)(4) since October 2025 with no batch-to-batch cleaning performed in between batches. These equipment were awaiting (b)(4) cleaning cycle of (b)(4) On 20-Jan-2026, your firm collected swab samples to conduct protocol (GD.004426) based evaluation to determine the risk for the potential carryover and cross-contamination of APIs from the areas of (b)(4) and tested swabs for active and degradant materials by HPLC while the equipment was in Duct of (b)(4) The swab samples showed failing test results for (b)(4) manufacturing for (b)(4) most of the sampling locations as follows: Table 1 (b)(4) Note: The above swab sample results are indicative of only approximately 5% of the actual (b)(4) materials that was present considering the swab stick could not adsorb/retain large amount of (b)(4) surface area that was swabbed for each swab sample on the (b)(4) (b)(4) In addition to API peaks, the swab samples showed numerous unknown peaks randomly eluting at different retention times in all swab samples tested by HPLC. These unknown peaks were not identified and accounted for in the above table. There is a potential (b)(4) that the unknown peaks could be degradants relating to APIs. On 20-Jan-2026, your firm collected most of the (b)(4) materials from (b)(4) duct of (b)(4) post (b)(4) collection of the swab samples. The reported quantities collected were (b)(4) These significantly large amount of (b)(4) materials were present (b)(4) in the bowl which may potentially cause cross-contamination between different drug substances that are using these non-dedicated (b)(4) (b)(4) B. Procedures used in the collection and analyses of swab samples are deficient. For example, 1. Your procedure for equipment cleaning is deficient in that there is no requirement for Batch-to-Batch cleaning. On 20-Jan-2026, we observed thick deposition of (b)(4) material throughout (b)(4) According to section (b)(4) of your cleaning procedure SOP.003095 (b)(4) (b)(4) cleaning of equipment is performed at the frequency of (b)(4) for (b)(4) while no Batch-to-Batch cleaning is performed. However, your firm changed (b)(4) cleaning to (b)(4) There was no justification provided for extending the duration of (b)(4) cleaning. 2. Your STP (AM.001019) is deficient in that there is no mention of swab blank solution preparation. In the absence of swab blank solution preparation procedure, your QC Analysts were testing swab diluent which does not include new swab stick which is treated similar to swab sample test solution preparation. 3. Your equipment cleaning validation (SOP.000300) and test (AM.001019) procedures does not specify the type of swab stick that should be used for the collection and testing of swab samples. On 20-Jan-2025, your production operator collected swab samples for chemical analyses using sterile cotton swab stick. This swab stick was unable to absorb (b)(4) material due to narrow tip. Additionally, your production operator swabbed by holding a swab stick in perpendicular position which exposed minimum area of the swab tip causing least adsorption of residual materials on swab stick. Moreover, your operator was leaving a wide gap while swabbing in vertical and horizontal directions leaving some areas not swabbed. There

      Shortened here; the PDF has the full text.

    2. Observation 2

      Failure to prevent contamination of intermediates and API

      Failure of production operations to prevent contamination of intermediate and API by other materials. Specifically, A. Your firm utilizes (b)(4) 101, for the manufacturing of (b)(4) During the walkthrough inspection on 19-Jan-2026, we observed several (b)(4) pieces inside the (b)(4) floating foreign materials that appeared to be (b)(4) water ready for the next batch, with visible observation, (b)(4) 101 contained (b)(4) in (b)(4) (b)(4) contamination present in the manufacturing environment. Further review of the manufacturing process confirmed that these bags holding (b)(4) (b)(4) pieces originate from the (b)(4) (b)(4) during the (b)(4) process into (b)(4) 101. According to the firm, the last time the (b)(4) were changed was on 4-Oct-2025, and your firm has manufactured approximately (b)(4) batches since then, indicating that this (b)(4) contamination issue has potentially affected (b)(4) batches without proper identification or corrective action to address the contamination source. The (b)(4) during the manufacturing process utilizes only (b)(4) to address the contamination source. The (b)(4) particles depending on their size (b)(4), which may be inadequate to remove all (b)(4) distribution, creating substantial risk that (b)(4) contamination could pass through the (b)(4) system (b)(4) and be incorporated into the finished API. B. During the walkthrough inspection of Site (b)(4) ID #(b)(4) I observed that the (b)(4) 302, used in the manufacture of (b)(4) API, was found to contain numerous scratches due to mechanical wear and tear in the product contact areas. Upon request, the (b)(4) was operated for approximately two (2) minutes, during which (b)(4) particles were visibly generated within the equipment, demonstrating active contamination of the manufacturing environment with (b)(4) debris that could be incorporated into the API during processing operations. I observed the same condition, visible scratches on the inner surface of (b)(4) ID #(b)(4) 301. This condition demonstrates inadequate preventive maintenance and poses a risk of (b)(4) contamination to the API. The use of equipment in this degraded state may adversely affect the quality of the drug substance. On 27-Jan-2026, your firm informed us that approximately (b)(4) had been shaved off from the inner surface of the (b)(4) ID #(b)(4) 302 based on the preliminary investigation.

    Show observation 3
    1. Observation 3

      Deficient environmental monitoring procedure

      Failure to have the procedures and processes necessary to ensure the API and intermediates manufactured at your facility meet established specifications for quality and purity. Specifically, Your firm's procedure SOP No. 001480: SOP for Environmental Monitoring of (b)(4) Content, Revision No. 12, Effective Date: 07/09/2025, is deficient. Your firm failed to monitor critical entry points; outside/exterior door handles from the external environment into the manufacturing facilities. (This is repeat observation from June-July 2022 inspection)

  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
  4. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Six requests to FDA under the Freedom of Information Act named this site, most recently on FY2023. Each one asked for a Form 483.

  • Inspection ending Jan 27, 2026OAI

    3 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Jun 4, 2026. FDAgent holds no copy that FDA posted.

    1. Aug 14, 2026FDA-FOIA-2026-7889Form 483· 1 of 4 sitesOpen
    2. Jul 22, 2026FDA-FOIA-2026-6992Form 483 + EIRRecords released
    3. May 19, 2026FDA-FOIA-2026-5081Form 483· 1 of 2 sitesRecords released
  • Inspection ending Jul 1, 2022OAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. FY2023FDA-FOIA-2023-7549Form 483Closed
  • Inspection date not given

    2 requests. FDA released records in answer to a request for its Form 483 on Jul 21, 2026. FDAgent holds no copy that FDA posted.

    1. Jul 10, 2026FDA-FOIA-2026-6622Form 483Records released
    2. Mar 9, 2026FDA-FOIA-2026-2351Form 483Closed, no reply from requester

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3004497364, one row per refused product line.

2 refusals on 2022-11-23 · charged NOT LISTED on 2, UNAPPROVED on 2 · no FDA sample analysis

FDA firm profile
  • 2022-11-23

    ROSUVASTATIN CALCIUM61JCG16

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsBFV-0772299-4/21/1

  • 2022-11-23

    ROSUVASTATIN CALCIUM61JCG16

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsBFV-0772299-4/11/1

Import alerts

FDA import alert pages, last synced Nov 23, 2026, 04:17 UTC. On a Red List, FDA can detain the firm's listed products without examining them.

  • 66-40Red ListDetention Without Physical Examination of Drugs From Firms Which Have Not Met Drug GMPsAlert on fda.gov

    Date published 2022-11-21

    FDA’s entry
    Centrient Pharmaceuticals India Private Limited · Bhai Mohan Singh Nagar, Village Toansa, District Sbs Nagar, Nawashahr, Punjab INDIA
    FDA’s inspection record for FEI 3004497364
    Centrient Pharmaceuticals India Private Limited · Bhai Mohan Singh Nagar, Village Toansa, District Sbs Nagar, Nawashahr, India

    Matched on exact firm name, street address and country. FDA printed no FEI on this entry.

    10 products

    • 55 - - - --Pharm Necess & Ctnr For Drug/Bio
    • 56 - - - --Antibiotics (Human/Animal)
    • 58 - - - --Human and Animal Therapeutic Biologic and Biosimilar Drugs
    Show 7 more products
    • 60 - - - --Human and Animal Drugs
    • 61 - - - --Human and Animal Drugs
    • 62 - - - --Human and Animal Drugs
    • 63 - - - --Human and Animal Drugs
    • 64 - - - --Human and Animal Drugs
    • 65 - - - --Human and Animal Drugs
    • 66 - - - --Human and Animal Drugs

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing
Registration runs through
Dec 31, 2027
Registrant
Centrient Pharmaceuticals Netherlands B.V.D-U-N-S 409002560

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Centrient Pharmaceuticals Netherlands B.V. (D-U-N-S 409002560) as the registrant for this site and the 3 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3004497364 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3004497364. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.