Batch records and documentation in FDA Form 483 observations
Master and batch production records, device history records, logbooks and good documentation practice. FDAgent finds 241 such observations in 143 Form 483s issued to 137 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 241
- Each quoted below
- Form 483s
- 143
- Posted by FDA
- Facilities
- 137
- Distinct FEIs
- Most recent
- Sep 28, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 80 in 2026
| Year | Observations |
|---|---|
| 2008 | 3 |
| 2009 | 0 |
| 2010 | 1 |
| 2011 | 0 |
| 2012 | 4 |
| 2013 | 4 |
| 2014 | 0 |
| 2015 | 3 |
| 2016 | 16 |
| 2017 | 12 |
| 2018 | 15 |
| 2019 | 13 |
| 2020 | 0 |
| 2021 | 7 |
| 2022 | 18 |
| 2023 | 22 |
| 2024 | 15 |
| 2025 | 28 |
| 2026 | 80 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
21 CFR 211.18021 CFR 211.18421 CFR 211.18621 CFR 211.18821 CFR 820.18121 CFR 820.184
A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“batch record*” · “batch production … record*” · “master production … record*” · “master batch record*” · “device history record*” · “device master record*” · “documentation practice*” · “logbook*” · “log book*” · “BPR*” · “MPR*” · “BMR*”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 241 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Conroe Welding Supply, IncInspection ended Apr 3, 2026 · FEI 1625647 · Observation 3
The quality unit failed to review and approve manufacturing production and control records, including those for packaging and labeling, to determine compliance with all established, approved written procedures before batches were released or distributed. Specifically, The product release approver signature line was blank on batch records dated (b) (4) (lots (b) (4)), and the batches were released without any documented approval. These lots were …
Contains “batch record*”Read the Form 483 →
Linde Gas & Equipment Inc.Inspection ended Apr 1, 2026 · FEI 2523408 · Observation 1
The firm failed to conduct thorough and adequate annual product reviews. Your document PD.OPS-0026, Revision 7, Internal Quality System Assessments and Product reviews, effective 2/2/2026, does not include specific requirements for conducting product-specific reviews of medical gases, including evaluation of batch records, testing results and stability data. Additionally, the 2023 - 2025 Quality Management reviews lacked Out-of-specification …
Contains “batch record*”Read the Form 483 →
Fagron Analytical Services, LLCInspection ended Mar 26, 2026 · FEI 3033031230 · Observation 1
… that pH test data generated by this equipment is complete, accurate, and attributable to specific individuals, or that historical data can be retrieved for batch record review or investigation purposes. The pH meter is used for release testing on the following products: Product (b) (4) (b) (4)
Contains “batch record*”Read the Form 483 →
Dendreon Pharmaceuticals LLCInspection ended Mar 25, 2026 · FEI 3008821247 · Observation 5
The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in processing and packing. Electronic records are used, but they do not meet requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records. A. On March 17, 2026, it was observed that the workstation used in the manufacturing process have a (b) (4) to document in the …
Opens with FDA's citation wording for 21 CFR 211.188(b)Read the Form 483 →
Cerovene Inc.Inspection ended Mar 23, 2026 · FEI 3005890568 · Observation 2
OBSERVATION 2 (Repeat) Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, A. Per your VP of Operations, your firm does not review data, audit trails and alarm reports generated by the HMI ((b) (4)) of your non-dedicated (b) (4) Mixer (b) (4) ID# (b) (4). Operators that use this equipment …
Contains “master production … record*”Read the Form 483 →
Aurorium LLCInspection ended Mar 6, 2026 · FEI 1628757 · Observation 3
… batch record) and laboratory testing. Examples of these forms include: + All forms and documents that are part of the batch record « Form 239A Reagent/Solution Preparation Log * Form 120A Label Control Form « Form 121A Label Issuance + Form 112B Pre-Shipment Review Log + Form 133D Total Unacceptable (b) (4) Count c) There is a failure to review and approve all quality-related documents. The analytical testing lab books (data collection form) used …
Contains “batch record*”Read the Form 483 →
Accura-Pac, Inc.Inspection ended Mar 5, 2026 · FEI 1818911 · Observation 1
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, a.[REPEAT OBSERVATION] Your firm has given “Analyst” role with the same privileges to the software system, (b) (4) to all the analytical lab personnel, including the analyst, the supervisor, and the manager. Some of the privileges …
Contains “master production … record*”Read the Form 483 →
Accura-Pac, Inc.Inspection ended Mar 5, 2026 · FEI 1818911 · Observation 3
Records are not kept for the cleaning of equipment. Specifically, Your firm has established and validated a dirty hold time (DHT) of (b) (4) for |] compounding tanks in the (b) (4) Compounding Area, which are used in the manufacture of drug products and cosmetics. However, the logbooks associated with these compounding tanks do not document the start and stop times for tank usage and cleaning. There are no controls in place to record how many …
Contains “logbook*”Read the Form 483 →
GSK Vaccines GmbHInspection ended Feb 27, 2026 · FEI 3001314775 · Observation 2
… Although each test failure is reviewed (b)(4) (b)(4) by Quality Assurance and documented in the Aluminum Hydroxide Adjuvant batch record, a formal investigation is not required for (b)(4) failures of this validated (b)(4) test performed using the [illegible]. A retrospective review identified a pattern of (b)(4) (b)(4) across (b)(4) consecutive batches manufactured in 2024 and periodic failures afterwards. The lack of documented investigations …
Contains “batch record*”Read the Form 483 →
Unilab Chemicals and Pharmaceuticals Private Ltd.Inspection ended Feb 27, 2026 · FEI 3004985767 · Observation 2
There is a failure to thoroughly review any unexplained discrepancy whether or not the API batch has already been distributed. A) According to the QA Manager, there have been no deviations or non-conformances reported since the previous 2019 inspection. However, the following equipment breakdowns recorded in the Breakdown Maintenance Record Logbook, Format No.: UNI/MAIN/006 and 2024-2025 CAPA logs did not include thorough investigation of the API …
Contains “logbook*”Read the Form 483 →
Unilab Chemicals and Pharmaceuticals Private Ltd.Inspection ended Feb 27, 2026 · FEI 3004985767 · Observation 3
… The logbook entry pre-dated for (b) (4) also included Done By, Checked By, and Reviewed By signatures that were already filled in as of (b) (4) C. According to the QA Manager, the Done By signature in Cleaning Record of Equipments Logbook is not signed by the actual person doing the work (Production Worker) due to English language barrier. The Done By signature name is instead filled in by the Microbiologist who also signs off on the adjacent …
Contains “logbook*”Read the Form 483 →
Unilab Chemicals and Pharmaceuticals Private Ltd.Inspection ended Feb 27, 2026 · FEI 3004985767 · Observation 4
GMP training is not conducted with sufficient frequency to assure that employees remain familiar with cGMP requirements applicable to them. Specifically, There is no documented GMP training (e.g. on Good Documentation Practices) and training on standard operating procedures applicable to the job functions of the Quality Control (QC) Lab Assistant, who is routinely involved with QC sampling activities and functions involving QC instrument cleaning …
Contains “documentation practice*”Read the Form 483 →
RayzeBio, IncInspection ended Feb 24, 2026 · FEI 3030530655 · Observation 2
… Batch records confirm no post-batch cleaning is performed. No risk assessment or justification supports this practice. D. On 02/02/2026, during the set-up and aseptic fill for (b)(4), lot (b)(4), in Suite (b)(4) (Room 1012), we observed the following: 1. During cleaning and set-up, production operators were observed donning non-sterile coveralls and non-sterile head hoods. Operators opened the (b)(4) front (both the (b)(4) and the (b)(4)) and …
Contains “batch record*”Read the Form 483 →
RayzeBio, IncInspection ended Feb 24, 2026 · FEI 3030530655 · Observation 11
Master production and control records lack a statement of theoretical yield including the maximum and minimum percentages of theoretical yield beyond which investigation is required. Specifically, The master batch record for the products (b)(4) Solution for infusion does not have theoretical yield specifications at final dilution stage of the drug product.
Opens with FDA's citation wording for 21 CFR 211.186(b)(7)Read the Form 483 →
Almon Healthcare Private LimitedInspection ended Feb 13, 2026 · FEI 3030509366 · Observation 1
… Furthermore, your QA unit completely deviated from SOP "Document destruction procedure SOP/QA/043" by failing to maintain a logbook documenting when and what quality documentation was destroyed and the name and signature of the person who destroyed the GMP documents. b. There is no QA oversight on batch issuance record to document who requested, received, returned and accepted the batch record. For example, QA issued a batch manufacturing record …
Contains “logbook*”Read the Form 483 →
Almon Healthcare Private LimitedInspection ended Feb 13, 2026 · FEI 3030509366 · Observation 6
Failure to clean equipment and utensils to prevent contamination or carry-over of a material that would alter the quality of the intermediates and API. a. Your firm uses a (b)(4) (b)(4) to [illegible]. No usage or cleaning logbook exists for this [illegible]. This is used in the manufacturing of different APIs including (b)(4) (b)(4) (b)(4) for the US market. b. On February 9, 2026, a (b)(4) (b)(4) (002) on them [illegible] floor showed apparent …
Contains “logbook*”Read the Form 483 →
Biomylz Private LimitedInspection ended Feb 9, 2026 · FEI 3013697420 · Observation 1
… 22, 2026, your firm terminated the former Plant Manager due to repeated and ongoing data integrity violations, including, but not limited to, destruction of batch production records, destruction of laboratory-controlled records, and documentation of false production and laboratory data. According to your Quality Head, employees working in the production and laboratory areas were instructed by the former Plant Manager to destroy, alter, or …
Contains “batch production … record*”Read the Form 483 →
SNJ Labs Private Ltd.Inspection ended Feb 6, 2026 · FEI 3026587575 · Observation 4
… The (b) (4) cleaning record showed that the room was last cleaned on (b) (4) and there was no documentation on the logbook for (b) (4) cleaning of ceiling. b. Clean room (b) (4) Plant (b) used for (b) (4) API (b) (4) was not in clean condition on February 2, 2026. Floors showed (b) (4) liquid like substance leaking from (b) (4) (b) (4) of (b) (4) materials scattered on the floor next to (b) (4) and (b) (4) liquid stains on floors and walls. The …
Contains “logbook*”Read the Form 483 →
Apotek Production & Laboratorier ABInspection ended Jan 29, 2026 · FEI 3003766921 · Observation 4
The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing and processing. Specifically, Batch records do not contain documentation of all interventions performed in the Grade A or the length of time taken to perform each intervention. Routine interventions not recorded include but are not limited to the following: a. Cleaning of b. Adjustment of …
Opens with FDA's citation wording for 21 CFR 211.188(b)Read the Form 483 →
Apotek Production & Laboratorier ABInspection ended Jan 29, 2026 · FEI 3003766921 · Observation 6
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, your firm’s gu Equipment ID ge does not save testing data generated from ag) nor is it attached to any type of system that will print or save the generated raw data. The current process relies on a single analyst to manually transcribe …
Contains “master production … record*”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.188Batch production and control recordsIn this theme's rule17
- 21 CFR 211.100Written procedures; deviations14
- 21 CFR 211.22Responsibilities of quality control unit13
- 21 CFR 211.68Automatic, mechanical, and electronic equipment13
- 21 CFR 211.113Control of microbiological contamination11
- 21 CFR 211.180General requirementsIn this theme's rule8
- 21 CFR 211.186Master production and control recordsIn this theme's rule5
- 21 CFR 211.42Design and construction features4
- 21 CFR 211.160General requirements4
- 21 CFR 211.192Production record review4
Ask FDAgent about batch records and documentation in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.