Unilab Chemicals and Pharmaceuticals Private Ltd. Form 483, February 2026
FDA issued this Form 483 to Unilab Chemicals and Pharmaceuticals Private Ltd. in Mumbai, India (FEI 3004985767) at the end of a drug inspection that ended February 27, 2026. It lists 5 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Oct 22, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Feb 27, 2026
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Oct 22, 2026
- 237 days after the inspection
The 5 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Unqualified suppliers and unvalidated COA verification
There is a failure to establish the reliability of the component supplier's report of analyses. Specifically, A) There is no supplier qualification or quality agreement established for the following non-USP solvents used for manufacturing APIs: (b) (4) B) Certificate of Analysis (COA) test results provided by the supplier of non-USP solvents have not been validated. This includes the lack of verification for Identity test results, (b) (4) Limit test results, (b) (4) Limit test results, Residue on Evaporation test results, pH test results, Solvent Acidity test results, Denaturant Level test results, and/or Impurity test results. In addition, the non-USP in-house test method used for Gas Chromatography (GC) purity testing has not been validated. According to the QA Manager, the test parameters for the in-house methods were solely determined based on the firm's laboratory capability. C) The firm's designated contract testing laboratory for (b) (4) water TOC testing has not been qualified. In addition, there is no quality agreement that defines GMP expectations and responsibilities relating to testing of (b) (4) water samples for TOC analysis. In addition, the (b) (4) water sampling and testing plan for TOC analysis is also not clearly defined or established. According to the Quality Assurance (QA) Manager, (b) (4) water samples for TOC analysis are collected from the (b) (4) vessel and only during the manufacturing of APIs intended for the U.S market.
- 2
Inadequate discrepancy investigation and unofficial records
There is a failure to thoroughly review any unexplained discrepancy whether or not the API batch has already been distributed. A) According to the QA Manager, there have been no deviations or non-conformances reported since the previous 2019 inspection. However, the following equipment breakdowns recorded in the Breakdown Maintenance Record Logbook, Format No.: UNI/MAIN/006 and 2024-2025 CAPA logs did not include thorough investigation of the API equipment breakdown incident (e.g., during which stage in activities), root cause analysis and product quality impact details on distributed API batches: Machine/Equipment No./Plant Location (b) (4) Breakdown Date Jan 06, 2025 Restart Date Jan 06, 2025 Root Cause (b) (4) Leakage Problem for (b) (4) Corrective Action New (b) (4) Fitting Work Completed Dec 01, 2024 Dec 01, 2024 (b) (4) Vessel (b) (4) Valve Leakage (b) (4) New valve fitted in (b) (4) CAPA No. Details of CAPA Date of Initiation Initiation By Quality Impact CAPAS Implemented On CAPA-043/25 Replaced the (b) (4) valve of (b) (4) Vessel (b) (4) in Formulation Manufacturing Area (b) due to observed leakage). (4) Sep. 29, 2025 Maintenance Yes Oct. 03, 2025 CAPA-020/25 New (b) (4) fitted to (b) (4) (b) (4) for Bulk Drug (API) Manufacturing Areas, which is connected to (b) (4) due to leakage. March 09, 2025 Maintenance Yes April 01, 2025 CAPA-016/24 Replaced (b) (4) valve of (b) (4) Vessel No. (b) (4) with spare valve (Reason not specified). March 27, 2024 Maintenance Yes April 01, 2024 B) During my inspection walkthrough of the Bulk Drug (API) Manufacturing Area on February 23, 2026, an uncontrolled notebook was observed to be stored away at the bottom of a box storing equipment auxiliary parts. According to the Director, the notebook contained unofficial documentation of (b) (4) (b) (4) recorded by Operators as part of (b) (4) (b) (4) study for (b) (4) USP and non-USP commercial batches. However, there is no official documentation of the study and operators' involvement during the commercial batch manufacturing process. In addition, the Director and R&D Associate stationed off-site stated that (b) (4) ml samples are (b) (4) collected from each commercial batch as part of the (b) (4) (b) (4) study. However, the collection of such samples is not documented nor included as part of the master batch manufacturing record instructions.
- 3
QC procedures not followed and poor documentation
The responsibilities and procedures applicable to the quality control unit are not in writing or fully followed. Specifically, The following deficiencies were observed during my inspectional walkthrough of the Quality Assurance (QA) area on February 23, 2026: A. 2025 Quality Control API test results (e.g. pH and Assay test results) were observed to be documented on loose uncontrolled template paper for commercial API batches. According to the Production Manager, this document template is no longer in use as of 2026 and all the remaining uncontrolled documents previously filled with similar GMP data have already been shredded. There is no record of which GMP documents have been previously shredded in 2025 and the years prior. B. The Microbiology Department's Cleaning Record of Equipment Log No. F/MIC/008 was pre-dated with equipment cleaning (Frequency: (b) (4)) already completed on (b) (4), which is (b) (4) since the last equipment cleaning documented for completion on (b) (4). The logbook entry pre-dated for (b) (4) also included Done By, Checked By, and Reviewed By signatures that were already filled in as of (b) (4) C. According to the QA Manager, the Done By signature in Cleaning Record of Equipments Logbook is not signed by the actual person doing the work (Production Worker) due to English language barrier. The Done By signature name is instead filled in by the Microbiologist who also signs off on the adjacent Checked By column. D. (b) (4) Vessel No-1 (UNI(b) (4)/01) Preventive Maintenance Record Logbook page intended for (b) (4) was already pre-filled with observations for machine parts, including: (b) (4) There is no documented reasoning as to why the observation page intended for (b) (4) were already prefilled without any signature or date. E. The Microbiology Department's Burning of (b) (4) Records Equipment Log No. F/MIC/005 was missing multiple entries of Laminar Air Flow (LAF) start and closing times. This is despite the Operated By and/or Checked By signatures already being completed. F. Multiple missing Checked By signatures in both the Equipment Logbook and Equipment Cleaning Logbook involving (b) (4) UNI(b) (4)/02 after the production operations completed on (b) (4) and then commencing again on (b) (4) (b) (4) UNI/(b) (4) 02 is used for the manufacturing process involving (b) (4) Solution USP batches.
- 4
Insufficient GMP training for QC and production staff
GMP training is not conducted with sufficient frequency to assure that employees remain familiar with cGMP requirements applicable to them. Specifically, There is no documented GMP training (e.g. on Good Documentation Practices) and training on standard operating procedures applicable to the job functions of the Quality Control (QC) Lab Assistant, who is routinely involved with QC sampling activities and functions involving QC instrument cleaning and equipment upkeep. There is also a lack GMP and SOP training for the Production Worker responsible for routinely cleaning microbiology and QC laboratory equipment.
- 5
Equipment cleaning failure with visible residue repeat
There is a failure to clean equipment and utensils to prevent contamination or carry-over of a material that would alter the quality of the API beyond the official or other established specifications. Specifically, There are no standard operating procedures or established instructions to perform and document a visual inspection of equipment subsequent to cleaning operations. For example: During my walkthrough of the Bulk Drug (API) Manufacturing Area on February 23, 2026, I observed that the (b) (4) of (b) (4) UNI (b) (4) 06 had visible (b) (4) residue product material all throughout the surfaces and (b) (4) gasket area. This is despite full equipment cleaning documented as already being completed on February 16, 2026. ***This is a Repeat Observation***
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.