Skip to content

Unilab Chemicals and Pharmaceuticals Private Ltd.

Plot W 32, Midc, Phase Ii, Dombivli (East), Mumbai, India

FEI 3004985767DUNS 915893696

FDA has 4 inspections on file for Unilab Chemicals and Pharmaceuticals Private Ltd. in Mumbai, India (FEI 3004985767), from 2012 to 2026. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below. One of the two FOIA requests for this site has asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, through Dec 31, 2026. Its registrant is Unilab Chemicals and Pharmaceuticals Private Limited (D-U-N-S 650073518).

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
4, 2012–2026
0 OAI · 4 VAI · 0 NAI
Inspections with 483 observations shown
1 of 4
Form 483s posted by FDA
↗
Requested under FOIA
2 requests, latest Jun 2, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Unqualified suppliers and unvalidated COA verification

      There is a failure to establish the reliability of the component supplier's report of analyses. Specifically, A) There is no supplier qualification or quality agreement established for the following non-USP solvents used for manufacturing APIs: (b) (4) B) Certificate of Analysis (COA) test results provided by the supplier of non-USP solvents have not been validated. This includes the lack of verification for Identity test results, (b) (4) Limit test results, (b) (4) Limit test results, Residue on Evaporation test results, pH test results, Solvent Acidity test results, Denaturant Level test results, and/or Impurity test results. In addition, the non-USP in-house test method used for Gas Chromatography (GC) purity testing has not been validated. According to the QA Manager, the test parameters for the in-house methods were solely determined based on the firm's laboratory capability. C) The firm's designated contract testing laboratory for (b) (4) water TOC testing has not been qualified. In addition, there is no quality agreement that defines GMP expectations and responsibilities relating to testing of (b) (4) water samples for TOC analysis. In addition, the (b) (4) water sampling and testing plan for TOC analysis is also not clearly defined or established. According to the Quality Assurance (QA) Manager, (b) (4) water samples for TOC analysis are collected from the (b) (4) vessel and only during the manufacturing of APIs intended for the U.S market.

    2. Observation 2

      Inadequate discrepancy investigation and unofficial records

      There is a failure to thoroughly review any unexplained discrepancy whether or not the API batch has already been distributed. A) According to the QA Manager, there have been no deviations or non-conformances reported since the previous 2019 inspection. However, the following equipment breakdowns recorded in the Breakdown Maintenance Record Logbook, Format No.: UNI/MAIN/006 and 2024-2025 CAPA logs did not include thorough investigation of the API equipment breakdown incident (e.g., during which stage in activities), root cause analysis and product quality impact details on distributed API batches: Machine/Equipment No./Plant Location (b) (4) Breakdown Date Jan 06, 2025 Restart Date Jan 06, 2025 Root Cause (b) (4) Leakage Problem for (b) (4) Corrective Action New (b) (4) Fitting Work Completed Dec 01, 2024 Dec 01, 2024 (b) (4) Vessel (b) (4) Valve Leakage (b) (4) New valve fitted in (b) (4) CAPA No. Details of CAPA Date of Initiation Initiation By Quality Impact CAPAS Implemented On CAPA-043/25 Replaced the (b) (4) valve of (b) (4) Vessel (b) (4) in Formulation Manufacturing Area (b) due to observed leakage). (4) Sep. 29, 2025 Maintenance Yes Oct. 03, 2025 CAPA-020/25 New (b) (4) fitted to (b) (4) (b) (4) for Bulk Drug (API) Manufacturing Areas, which is connected to (b) (4) due to leakage. March 09, 2025 Maintenance Yes April 01, 2025 CAPA-016/24 Replaced (b) (4) valve of (b) (4) Vessel No. (b) (4) with spare valve (Reason not specified). March 27, 2024 Maintenance Yes April 01, 2024 B) During my inspection walkthrough of the Bulk Drug (API) Manufacturing Area on February 23, 2026, an uncontrolled notebook was observed to be stored away at the bottom of a box storing equipment auxiliary parts. According to the Director, the notebook contained unofficial documentation of (b) (4) (b) (4) recorded by Operators as part of (b) (4) (b) (4) study for (b) (4) USP and non-USP commercial batches. However, there is no official documentation of the study and operators' involvement during the commercial batch manufacturing process. In addition, the Director and R&D Associate stationed off-site stated that (b) (4) ml samples are (b) (4) collected from each commercial batch as part of the (b) (4) (b) (4) study. However, the collection of such samples is not documented nor included as part of the master batch manufacturing record instructions.

    Show observations 3 to 5
    1. Observation 3

      QC procedures not followed and poor documentation

      The responsibilities and procedures applicable to the quality control unit are not in writing or fully followed. Specifically, The following deficiencies were observed during my inspectional walkthrough of the Quality Assurance (QA) area on February 23, 2026: A. 2025 Quality Control API test results (e.g. pH and Assay test results) were observed to be documented on loose uncontrolled template paper for commercial API batches. According to the Production Manager, this document template is no longer in use as of 2026 and all the remaining uncontrolled documents previously filled with similar GMP data have already been shredded. There is no record of which GMP documents have been previously shredded in 2025 and the years prior. B. The Microbiology Department's Cleaning Record of Equipment Log No. F/MIC/008 was pre-dated with equipment cleaning (Frequency: (b) (4)) already completed on (b) (4), which is (b) (4) since the last equipment cleaning documented for completion on (b) (4). The logbook entry pre-dated for (b) (4) also included Done By, Checked By, and Reviewed By signatures that were already filled in as of (b) (4) C. According to the QA Manager, the Done By signature in Cleaning Record of Equipments Logbook is not signed by the actual person doing the work (Production Worker) due to English language barrier. The Done By signature name is instead filled in by the Microbiologist who also signs off on the adjacent Checked By column. D. (b) (4) Vessel No-1 (UNI(b) (4)/01) Preventive Maintenance Record Logbook page intended for (b) (4) was already pre-filled with observations for machine parts, including: (b) (4) There is no documented reasoning as to why the observation page intended for (b) (4) were already prefilled without any signature or date. E. The Microbiology Department's Burning of (b) (4) Records Equipment Log No. F/MIC/005 was missing multiple entries of Laminar Air Flow (LAF) start and closing times. This is despite the Operated By and/or Checked By signatures already being completed. F. Multiple missing Checked By signatures in both the Equipment Logbook and Equipment Cleaning Logbook involving (b) (4) UNI(b) (4)/02 after the production operations completed on (b) (4) and then commencing again on (b) (4) (b) (4) UNI/(b) (4) 02 is used for the manufacturing process involving (b) (4) Solution USP batches.

    2. Observation 4

      Insufficient GMP training for QC and production staff

      GMP training is not conducted with sufficient frequency to assure that employees remain familiar with cGMP requirements applicable to them. Specifically, There is no documented GMP training (e.g. on Good Documentation Practices) and training on standard operating procedures applicable to the job functions of the Quality Control (QC) Lab Assistant, who is routinely involved with QC sampling activities and functions involving QC instrument cleaning and equipment upkeep. There is also a lack GMP and SOP training for the Production Worker responsible for routinely cleaning microbiology and QC laboratory equipment.

    3. Observation 5

      Equipment cleaning failure with visible residue repeat

      There is a failure to clean equipment and utensils to prevent contamination or carry-over of a material that would alter the quality of the API beyond the official or other established specifications. Specifically, There are no standard operating procedures or established instructions to perform and document a visual inspection of equipment subsequent to cleaning operations. For example: During my walkthrough of the Bulk Drug (API) Manufacturing Area on February 23, 2026, I observed that the (b) (4) of (b) (4) UNI (b) (4) 06 had visible (b) (4) residue product material all throughout the surfaces and (b) (4) gasket area. This is despite full equipment cleaning documented as already being completed on February 16, 2026. ***This is a Repeat Observation***

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on Jun 2, 2026. Each one asked for a Form 483.

  • Inspection ending Feb 27, 2026VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Jun 2, 2026FDA-FOIA-2026-5479Form 483Records released
  • Inspection ending Nov 22, 2019VAI

    1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 + EIR on Oct 26, 2025. FDAgent holds no copy that FDA posted.

    1. Sep 5, 2025FDA-FOIA-2025-10605Form 483 + EIRRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing
Registration runs through
Dec 31, 2026
Registrant
Unilab Chemicals and Pharmaceuticals Private LimitedD-U-N-S 650073518

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3004985767 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3004985767. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.