Conroe Welding Supply, Inc
4425 N Frazier St, Conroe, Texas, United States
FEI 1625647DUNS 074194994
FDA has 2 inspections on file for Conroe Welding Supply, Inc in Conroe, Texas (FEI 1625647), from 2016 to 2026. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below. Two FOIA requests have asked FDA for this inspection's 483.
No court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2027. Its registrant is CONROE WELDING SUPPLY INC (D-U-N-S 074194994).
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 2, 2016–2026
- 1 OAI · 0 VAI · 1 NAI
- Inspections with 483 observations shown
- 1 of 2
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 2 requests, latest Aug 12, 2026
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
No quality unit or QMS established
There is no quality unit. Specifically, Your firm has not established, documented, or implemented an effective quality management system and current good manufacturing practice (cGMP) that involves the active participation of management, quality, and appropriate manufacturing personnel. Your firm's quality unit lacks sufficient resources to carry out its responsibilities and consistently ensure medical gas quality. For example: A. Your firm has not designated any personnel to serve in quality assurance roles. B. Your firm failed to establish written procedures that define the roles, responsibilities, and procedures of quality unit personnel. It was observed on batch records that the filler, tester, and product release approver were the same person, demonstrating a lack of independent verification and segregation of duties, as shown on batch records dated (b) (4) (lot (b) (4)), (b) (4) (lots (b) (4)), (b) (4) (lot (b) (4)), (b) (4) (lots (b) (4) (b) (4)), and (b) (4) (lots (b) (4)). Your firm distributed these lots to customers. C. Your firm failed to provide cGMP training to employees involved in cGMP manufacturing and failed to establish a standard operating procedure (SOP) for training management. D. Your firm failed to conduct annual product reviews of medical gas being filled and distributed at your facility and failed to establish an SOP for annual product review management. Your firm has never conducted any annual product reviews of (b) (4) medical gas. E. Your firm failed to establish SOPs for deviation, out-of-specification, investigation, and corrective action/preventive action. Your firm failed to record and maintain records of these events. F. Your firm failed to record operational major changes. Your firm moved to a new location in February 2026, but no record of the relocation was documented and no risk assessment was conducted. Your firm failed to establish an SOP for change control management. Additionally, after a customer complaint regarding the presence of (b) (4) gas in a medical (b) (4) vessel, your firm (b) (4) when product testing is performed; however, this change was not recorded. G. Your firm failed to conduct internal audits and has never performed one. Your firm failed to establish an internal audit SOP. H. Your firm failed to provide good documentation practice training to employees and failed to establish a good documentation practice SOP. It was observed that batch production records contained blackouts, overwriting, cross-outs, and corrections without dates and initials, including but not limited to batch records dated (b) (4) and (b) (4). Additionally, it was observed that some empty boxes in batch records were lined through and some were not, including but not limited to batch records dated (b) (4), (b) (4) and (b) (4). I. Your investigation into customer complaints was inadequate. Your firm received two customer complaints in 2025; however, you did not maintain complete records of the investigations and performed incomplete investigations. Additionally, your firm's customer complaint SOP is inadequate because it does not include important elements, including but not limited to complaint investigation procedures. The SOP also lacks an effective date, version number, and reviewer/approver signature. J. Your firm failed to conduct supplier audits and failed to establish a supplier audit management SOP. Your firm has never performed supplier audits. K. Your recall SOP is inadequate. It does not include important elements, including but not limited to investigation procedures. Additionally, the SOP does not have an effective date, version number, or reviewer/approver signature. L. Your firm failed to maintain records of medical gas distribution. For example, your firm could not locate records to determine whether lots (b) (4) and (b) (4), and 6 out of [illegible] units of lot (b) (4) were distributed to customers or disposed. M. Your firm failed to establish a preventative maintenance SOP for (b) (
Shortened here; the PDF has the full text.
- Observation 2
Batch records missing significant packaging steps
Batch production records do not include documentation that each significant step in the packaging of the medical gas was performed. Specifically, Source bulk (b) (4) lot numbers were not recorded on batch records dated (b) (4) (lots (b) (4)), (b) (4) (lots (b) (4)), and (b) (4) (lots (b) (4)). These lots were distributed to customers.
Show observations 3 to 5
- Observation 3
Batches released without quality unit approval
The quality unit failed to review and approve manufacturing production and control records, including those for packaging and labeling, to determine compliance with all established, approved written procedures before batches were released or distributed. Specifically, The product release approver signature line was blank on batch records dated (b) (4) (lots (b) (4)), and the batches were released without any documented approval. These lots were distributed to customers.
- Observation 4
No testing of bulk medical gas
Your firm failed to perform required tests on bulk medical (b) (4) USP received for production. Specifically, No testing was performed on any bulk lot of medical (b) (4) USP received from your supplier. Your firm has not established and maintained a program to ensure the reliability of the supplier's capabilities through appropriate assessment and testing procedures.
- Observation 5
No equipment performance and maintenance program
Your firm failed to establish a written program designed to ensure proper performance of automatic, mechanical, and electronic equipment used to produce medical (b) (4). Specifically, The new (b) (4) equipment ((b) (4) Pumping System) used for production and the (b) (4) used for testing lack a written program to ensure proper performance and maintenance. Your firm uses this equipment to fill and test medical (b) (4) gas distributed to customers.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on Aug 12, 2026. Each one asked for a Form 483.
Inspection ending Apr 3, 2026OAI
2 requests. In the inspection history above. FDA has posted its Form 483.
- Aug 12, 2026FDA-FOIA-2026-7755Form 483· 1 of 3 sitesRecords released
- Jun 9, 2026FDA-FOIA-2026-5642Form 483· 1 of 5 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing
- Registration runs through
- Dec 31, 2027
- Registrant
- CONROE WELDING SUPPLY INCD-U-N-S 074194994
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1625647 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1625647. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.