Nippon Kayaku Co., Ltd
239, Iwahana-Machi, Takasaki, Japan
FEI 3002807722DUNS 706286366
FDA has 5 inspections on file for Nippon Kayaku Co., Ltd in Takasaki, Japan (FEI 3002807722), from 2012 to 2026. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its one observation from the PDF; it is listed below. One of the four FOIA requests for this site has asked FDA for this inspection's 483, and one more for the records from a later inspection, ending Jun 12, 2026, that FDA's Data Dashboard doesn't list yet.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing and analysis, through Dec 31, 2026. Its registrant is Nippon Kayaku Co., Ltd. (D-U-N-S 690547468).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 5, 2012–2026
- 0 OAI · 5 VAI · 0 NAI
- Inspections with 483 observations shown
- 1 of 5
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 4 requests, latest Oct 18, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 1 observation
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Deficient oversight of laboratory electronic systems
Supervisory oversight over the laboratory electronic systems and data is deficient. Specifically, A. Your firm does not reconcile official GMP documents issued from your ArcSuite Engineering document management system. Your firm uses ArcSuite Engineering to issue test records used for GMP testing and to issue manufacturing batch records. You stated the documents are approved by QA in the electronic system prior to printing out, but your firm does not have an audit trail or document history tracing each document that has been printed out. In addition, your firm does not reconcile all of the official GMP documents printed from ArcSuite Engineering. Your firm implemented ArcSuite engineering in April 2020 and uses it to issue official GMP records for manufacturing and testing of (b)(4) API. B. Your firm does not review 100% of the audit trails and electronic data in your Lab Solutions chromatography software. Your firm reviews the audit trails related to batch release testing, but your firm does not review all of the data generated between batch release testing. You are unable to confirm the presence or the absence of trial injections or other illegitimate testing due to the lack of 100% review. Your firm uses Lab Solutions for performing finished product testing on (b)(4) API.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: DevicesCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Four requests to FDA under the Freedom of Information Act named this site, most recently on Oct 18, 2026.
Inspection ending Jun 12, 2026
1 request. Not listed in FDA’s Data Dashboard yet.
- Oct 18, 2026FDA-FOIA-2026-10125EIR· 1 of 3 sitesOpen
Inspection ending May 29, 2026VAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Aug 3, 2026FDA-FOIA-2026-7445Form 483· 1 of 2 sitesRecords released
Inspection date not given
2 requests. FDA released records in answer to a request for its Form 483 on Jul 17, 2026. FDAgent holds no copy that FDA posted.
- Jul 10, 2026FDA-FOIA-2026-6603EIR· 1 of 2 sitesRecords released
- Jul 2, 2026FDA-FOIA-2026-6292Form 483Records released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing, analysis
- Registration runs through
- Dec 31, 2026
- Registrant
- Nippon Kayaku Co., Ltd.D-U-N-S 690547468
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3002807722 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3002807722. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.