LGM Pharma Solutions, LLC Form 483, May 2026
FDA issued this Form 483 to LGM Pharma Solutions, LLC in California (FEI 3017140477) at the end of an inspection that ended May 18, 2026. It lists 4 observations.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 17, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- May 18, 2026
- —
- FDA's outcome
- Not classified
- Not classified yet
- Posted by FDA
- Nov 17, 2026
- 183 days after the inspection
The 4 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate production controls for variable material
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, Your firm failed to establish adequate controls to manage variability in commercial production of (b) (4) Tablets despite acknowledging in both the Validation Protocol (DOC-021270) and Validation Report (DOC-021423) that (b) (4) is a naturally variable material with inherent physical and chemical variability. For example: 1. Multiple Out-of-Specification (OOS) investigations were initiated following above-specification results. Three of these OOS results (CA25-018, CA25-048, and CA25-063) were linked to Batch (b) (4), which also showed an (b) (4) assay trend, while one additional OOS result (CA25-019) was associated with Batch (b) (4). Both batches had been released in December 2024 and are currently on stability studies. 2. The batch record lists hardness and thickness limits as "Record Only," providing no enforceable in-process trigger to detect or respond to compression drift during tableting.
- 2
Unsound assay specs and incomplete method validation
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that components, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, 1. Your specifications for assay of (b) (4) tablet, a (b) (4) drug, does not appear to be sufficiently (b) (4) as the specifications are set at (b) (4) 2. The Assay Method Validation Report for (b) (4) (b) (4) is incomplete and has not been updated in accordance with current procedures. For example: a) The validation report covers only Accuracy, Precision, Linearity, LOD/LOQ, Ruggedness, and Robustness; Specificity, (b) (4) Study, and Solution Stability parameters are absent from the report. b) The validation was conducted in 2007, predating the implementation of DOC-015071 "General Guidelines for Method Validation/Verification" (effective 2023) by approximately 16 years, and the report has not been revised to reflect current validation requirements outlined therein.
- 3
Failure to investigate recurring TAMC OOS failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, Your firm failed to thoroughly investigate three recurring Total Aerobic Microbial Count (TAMC) Negative Control OOS failures (OOS CA25-050, CA25-052, and CA25-057) occurring between August 19 and September 19, 2025. Each failure was treated as an isolated incident attributed to analyst error, without evaluating the (b) (4) (Lot #(b) (4), Bottle #(b) (4)), which was a common material shared across all three events, as a potential root cause, and without extending the investigation to other potentially affected batches and products. Lot #(b) (4) was used to test (b) (4) different samples prior to disposal. The true root cause, a pre-contaminated (b) (4) bottle, was not identified until the third OOS event (CA25-057), when visible microbial growth was observed in the remaining (b) (4).
- 4
Reserve samples not examined annually for deterioration
Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration. Specifically, Your firm's annual product review process includes visual examination of a subset lots of reserve samples during the first year, according to SOP titled "Annual Product Review" (DOC-001071, Rev 10, Effective Date 14 March 2023). Your firm has not conducted the required annual visual examinations of reserve samples in subsequent years to assess for signs of deterioration. For example, for the 2022-2023 review period, retain samples for all (b) (4) manufactured lots of (b) (4) (b) (4) Capsule were examined in August 2023 but were not re-examined in 2024, despite the products remaining within their expiry dates.
After this inspection
FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.
- Warning LetterNov 2, 2026LGM Pharma Solutions, LLC warning letter, November 2, 2026CDER · 168 days after this inspection ended
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.