Laboratory controls in FDA Form 483 observations
Quality control laboratories: test methods and their validation, laboratory records and equipment, reference standards and chromatography. FDAgent finds 304 such observations in 172 Form 483s issued to 163 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 304
- Each quoted below
- Form 483s
- 172
- Posted by FDA
- Facilities
- 163
- Distinct FEIs
- Most recent
- Sep 3, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 76 in 2026
| Year | Observations |
|---|---|
| 2008 | 1 |
| 2009 | 0 |
| 2010 | 0 |
| 2011 | 0 |
| 2012 | 8 |
| 2013 | 0 |
| 2014 | 5 |
| 2015 | 4 |
| 2016 | 13 |
| 2017 | 21 |
| 2018 | 23 |
| 2019 | 14 |
| 2020 | 0 |
| 2021 | 6 |
| 2022 | 18 |
| 2023 | 42 |
| 2024 | 25 |
| 2025 | 48 |
| 2026 | 76 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
21 CFR 211.16021 CFR 211.16521 CFR 211.16621 CFR 211.16721 CFR 211.17021 CFR 211.17321 CFR 211.176
The same entries the laboratory controls topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“laboratory control*” · “laboratory record*” · “laboratory investigation*” · “laboratory equipment” · “laboratory instrument*” · “laboratory data” · “laboratory test*” · “laboratory result*” · “laboratory analyst*” · “laboratory procedure*” · “laboratory notebook*” · “laboratory error*” · “QC laborator*” · “quality control laborator*” · “test method*” · “analytical method*” · “analytical procedure*” · “method validation” · “HPLC*” · “chromatograph*” · “reference standard*” · “system suitability” · “method transfer”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 304 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Claris Injectables LimitedInspection ended Aug 26, 2016 · FEI 3004610460 · Observation 3
OBSERVATION 3 The use of apparatus not meeting established specifications was observed. Specifically, the ™* used during sterility testing has not been qualified for that purpose.
Opens with FDA's citation wording for 21 CFR 211.160(b)(4)Read the Form 483 →
Sekisui MedicalInspection ended Jun 17, 2016 · FEI 3002806840 · Observation 1
Failure to maintain and review all raw data. 1. Until 06 June 2016, procedures did not require that all raw data be maintained. Only reported data was maintained. Analysts deleted or did not submit test data that would not be reported. This was done without oversight. Review of electronic files from the HPLC and GC computers found the presence of hundreds of deleted or unreported chromatograms. Deleted files were also observed on the IR-3 system. …
Contains “HPLC*”Read the Form 483 →
Sekisui MedicalInspection ended Jun 17, 2016 · FEI 3002806840 · Observation 2
Failure to prevent unauthorized access of changes to data and to provide adequate controls to prevent omissions of data. 1. Electronic GC chromatography data from GC-7, collected prior to March 2016, was not available for review. This instrument was used for release testing of ® and“ , products for the US market. The stand-alone computers associated with the GC were discarded. Data was backed-up onto an external drive, but could not be restored …
Contains “chromatograph*”Read the Form 483 →
Drug Depot Inc. dba APS PharmacyInspection ended Jan 22, 2016 · FEI 3010621916 · Observation 6
Each batch of drug product purporting to be sterile is not laboratory tested to determine conformance to such requirements. Specifically, A. Your firm has not validated sterility testing to ensure substances in your product formulations do not interfere with the test and if they can detect low levels of organisms. In addition growth promotion testing is not conducted for media used for sterility testing in-house. B. Your firm has never performed …
Opens with FDA's citation wording for 21 CFR 211.167(a)Read the Form 483 →
Cosma SpAInspection ended Jan 15, 2016 · FEI 3002806754 · Observation 1
Observation 1 Failure to maintain complete data derived from all testing and to ensure compliance with established specifications and standards pertaining to data retention and management. Specifically, I. 1. Data can be overwritten and/or deleted on 4 out of the HPLCs and 2 out of @ GCs used in the testing of APIs manufactured for the U.S. market. These systems do not have audit trails or password protection for individual operators. [illegible] …
Contains “HPLC*”Read the Form 483 →
Cosma SpAInspection ended Jan 15, 2016 · FEI 3002806754 · Observation 5
Observation 5 Quality was not performing the following activities: 1. The GC system is not proven as suitable prior the running of residual solvents samples. System suitability is run after the samples are injected. This holds true for the residual solvents analysis for all API products for the U.S. market. 2. The HPLC system is not proven as suitable prior to the running of Enantiomeric Purity of] API. 3. Cleaning logs for production equipment …
Contains “system suitability”Read the Form 483 →
Zhejiang Medicine Co.Inspection ended Jun 18, 2015 · FEI 3003631275 · Observation 1
OBSERVATION 1 Laboratory control procedures are not followed. Specifically, during our review of your firm's Quality Control laboratory electronic chromatography data, we identified significant deviations from your laboratory control procedures. Our review found that samples are pre-tested multiple times prior to performing the official/reported analysis. This trial analysis data was performed and saved within your auxiliary "R&D" project …
Contains “laboratory control*”Read the Form 483 →
Zhejiang Medicine Co.Inspection ended Jun 18, 2015 · FEI 3003631275 · Observation 2
OBSERVATION 2 QC Laboratory records are not documented contemporaneously. Specifically, A) During our inspection of your finished API Quality Control Laboratory on June 15, 2015, we observed that a QC analyst pasted balance weighing slips, which were generated on June 11, 2015, onto the “Testing Original Records of®@ DS” worksheet (Lot #: 9 and signed her name and back dated as June 11, 2015. B) During our inspection of your finished API Quality …
Contains “laboratory record*”Read the Form 483 →
Master Pharm LLCInspection ended May 6, 2015 · FEI 3005734706 · Observation 5
OBSERVATION 5 Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements. Your firm does not test every sterile drug lot produced for sterility or endotoxins. Sterile drugs produced from non-sterile components are tested for sterility and endotoxins only for batches (b)(4).
Opens with FDA's citation wording for 21 CFR 211.167(a)Read the Form 483 →
Custom Compounding CenterInspection ended Apr 9, 2015 · FEI 3002401385 · Observation 5
There is no written testing program designed to assess the stability characteristics of drug products. Specifically, on 03/30/2015, your firm's Owner/Pharmacist-in-Charge stated your firm failed to have a written stability program for all sterile and non-sterile drug products.
Opens with FDA's citation wording for 21 CFR 211.166(a)Read the Form 483 →
Vann Healthcare Services IncInspection ended Sep 24, 2014 · FEI 1000220363 · Observation 3
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing. Specifically, There is no sterility or endotoxin test data for: a. Lidocaine 4% injectable with a 60 day beyond use period at refrigerated storage. b. Epinephrine 1:1000 injection with a 30 day beyond use period at room temperature storage. c. Hydroxyprogesterone caproate injection, 250 mg/ml, with a 90 day beyond …
Opens with FDA's citation wording for 21 CFR 211.165(b)Read the Form 483 →
Vann Healthcare Services IncInspection ended Sep 24, 2014 · FEI 1000220363 · Observation 4
There is no written testing program designed to assess the stability characteristics of drug products. Specifically, There is no potency test data to support the beyond use dating periods assigned for: a. Lidocaine 4% injectable with a 60 day beyond use period at refrigerated storage. b. Epinephrine 1:1000 injection with a 30 day beyond use period at room temperature storage. c. Hydroxyprogesterone caproate injection, 250 mg/ml, with a 90 day …
Opens with FDA's citation wording for 21 CFR 211.166(a)Read the Form 483 →
DNA Pharmacy Services Inc dba Palm Beach CompoundingInspection ended Aug 13, 2014 · FEI 3004962739 · Observation 1
There is no written testing program designed to assess the stability characteristics of drug products. Specifically, there is no data to justify the beyond use date of more than 9 months for Testosterone Cypionate Injection 220 mg/mL Lot 03/02/2014:1106 that you produced on 03/02/2014 and currently distribute with a BUD of 12/27/2014. The stability data you generated for this product only supports a BUD of 3 months.
Opens with FDA's citation wording for 21 CFR 211.166(a)Read the Form 483 →
DNA Pharmacy Services Inc dba Palm Beach CompoundingInspection ended Aug 13, 2014 · FEI 3004962739 · Observation 2
Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements. Specifically, Testosterone Cypionate Injection 220 mg/mL Lot 03/02/2014:1106 produced on 03/02/2014 is currently distributed with a BUD of 12/27/2014 (9 months) even though there is no current sterility and endotoxin testing data to demonstrate that this lot is safe, effective, and stable for nine months.
Opens with FDA's citation wording for 21 CFR 211.167(a)Read the Form 483 →
Infusion Options, Inc.Inspection ended Apr 23, 2014 · FEI 3008231170 · Observation 6
Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements. Specifically, given the observed inadequate environmental controls, testing is deficient in that: a. Your firm has not conducted sterility testing for any batches (totaling [illegible] units) of outsourced sterile drugs since the registration date of 01/24/14. b. Endotoxin testing has not been performed for …
Opens with FDA's citation wording for 21 CFR 211.167(a)Read the Form 483 →
Boston Analytical, Inc.Inspection ended Nov 9, 2012 · FEI 1221426 · Observation 1
Written production and process control procedures are not followed in the execution of production and process control functions. Specifically, the following SOPs were not followed: a.) SOP P-1050, Version 16 Laboratory Investigation Policy, states all unexpected, out of trend or out of specification results are to be investigated however this was not followed for the following samples analyzed: * Monosodium Glutamate Project #(b)(4), Sample …
Contains “laboratory investigation*”Read the Form 483 →
Boston Analytical, Inc.Inspection ended Nov 9, 2012 · FEI 1221426 · Observation 2
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. a.) Specifically, described in SOP P-900 General Analytical Procedures not following test procedures for analysis of the following samples: Levofloxacin (Project Number (b)(4), Sample (b)(4)), Assay test and Impurities test not …
Opens with FDA's citation wording for 21 CFR 211.160(b)Read the Form 483 →
Boston Analytical, Inc.Inspection ended Nov 9, 2012 · FEI 1221426 · Observation 3
Employees engaged in the processing of a drug product lack the training required to perform their assigned functions. Specifically, a.) Introduction to cGMPs training records for Director of Chemistry Laboratories not signed by trainer. b.) According to training records analyst received training in HPLC Analysis dated 11/05/12, however while observing analyst conducting HPLC analysis the analyst also could not identify the precipitate that was …
Contains “HPLC*”Read the Form 483 →
ARL Biopharma, Inc. dba Analytical Research LaboratoriesInspection ended Nov 8, 2012 · FEI 3003644883 · Observation 1
1. Your firm states on the Microbiology Report that is issued to a client after sterility and/or fungal testing that the Test Method employed was USP <71>. However, your firm is not fully following all parts of USP <71> when performing sterility and/or fungal testing of human drug products. For example, a. USP <71> requires a Method Suitability Test be performed for all new products tested. Your firm does not have documentation to show that …
Contains “test method*”Read the Form 483 →
ARL Biopharma, Inc. dba Analytical Research LaboratoriesInspection ended Nov 8, 2012 · FEI 3003644883 · Observation 2
2. Your firm has no documentation to show that all analytical methods used to test for potency (assay) have been validated for all drug products including drug products submitted for testing by NECC and Ameridose LLC. These include drug products such as Methylprednisolone Acetate, Heparin, Vasopressin, Triamcinolone Acetonide, and products containing Bupivacaine and Epinephrine. Analytical methods that are not validated and/ or not found in the …
Contains “analytical method*”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.160General requirementsIn this theme's rule40
- 21 CFR 211.165Testing and release for distributionIn this theme's rule24
- 21 CFR 211.166Stability testingIn this theme's rule21
- 21 CFR 211.194Laboratory records17
- 21 CFR 211.192Production record review15
- 21 CFR 211.22Responsibilities of quality control unit12
- 21 CFR 211.167Special testing requirementsIn this theme's rule6
- 21 CFR 211.170Reserve samplesIn this theme's rule6
- 21 CFR 211.68Automatic, mechanical, and electronic equipment5
- 21 CFR 211.110Sampling and testing of in-process materials and drug products3
Ask FDAgent about laboratory controls in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
- Laboratory controls: FDA's Form 483 citations of the same 21 CFR entries
- Aseptic processing: FDA's Form 483 citations of overlapping 21 CFR entries
- Stability: FDA's Form 483 citations of overlapping 21 CFR entries
- Every Form 483 theme, with its counts
- What a Form 483 is, and the latest 483s
- Every 21 CFR section in FDA's Form 483 citations