Zhejiang Medicine Co. Form 483, June 2015

FDA issued this Form 483 to Zhejiang Medicine Co. in Xinchang, China (FEI 3003631275) at the end of a drug inspection that ended June 18, 2015. It lists 8 observations. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Dec 15, 2016. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Jun 18, 2015
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Dec 15, 2016
546 days after the inspection
Facility
FEI 3003631275
Xinchang, China

The 8 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Laboratory control procedures not followed

    OBSERVATION 1 Laboratory control procedures are not followed. Specifically, during our review of your firm's Quality Control laboratory electronic chromatography data, we identified significant deviations from your laboratory control procedures. Our review found that samples are pre-tested multiple times prior to performing the official/reported analysis. This trial analysis data was performed and saved within your auxiliary "R&D" project folders. All raw data (e.g. sample weight/dilutions) pertaining to these trial sample analyses are discarded. Our review of the historical data collected for residual solvent by GC testing of OAPI identified what appear to be potentially significant differences between the trial and official results, including sample results that appear to include unknown peaks, which may cause the batches to be considered out-of-specification. However, due to the lack of supporting raw data (e.g. sample weights/dilutions), an accurate calculation of the residual solvent levels was not possible. Notably, your firm has initiated a total of 1 OOS investigation (including raw materials, in-process and finished products) since 01/2013 deemed to be due to laboratory error. For example: (b) (4) ©) (4) A) API batch # - The initial trial sample analysis was performed on 05/01/13 starting at 11:10am - The second trial sample analysis was performed on 05/03/13 starting at 10:31am - The official/reported analysis was performed on 05/03/13 starting at Be (b) (4) . B) “API batch - The initial trial sample analysis was performed on 06/18/13 starting at 9:52am - The second trial sample analysis was performed on 06/18/13 starting at 3:23pm - The official/reported analysis was performed on 06/18/13 starting at Be C) ©) “apr batch 4 (b) (4) - A trial sample analysis was performed on 04/22/13 starting at 9:52am - The official/reported analysis was performed on 04/23/13 starting at BE D) ©® 4 pI batch # ®@ - A trial sample analysis was performed on 06/13/13 starting at 10:07am - The official/reported analysis was performed on 06/13/13 starting at El ©) 4) E) API batch # Ee - The initial trial sample analysis was performed on 04/22/13 starting at 12:26pm - The second trial sample analysis was performed on 04/22/13 starting at 4:00pm - The official/reported analysis was performed on 04/22/13 starting at Be

  2. 2

    QC records not documented contemporaneously

    OBSERVATION 2 QC Laboratory records are not documented contemporaneously. Specifically, A) During our inspection of your finished API Quality Control Laboratory on June 15, 2015, we observed that a QC analyst pasted balance weighing slips, which were generated on June 11, 2015, onto the “Testing Original Records of®@ DS” worksheet (Lot #: 9 and signed her name and back dated as June 11, 2015. B) During our inspection of your finished API Quality Control Laboratory on June 15, 2015, we observed an analyst performing a calculation for “SST Record for HPLC Analysis of (USP)- Chromatographic Purity” based on the HPLC test data generated on June 10, 2015. However, the blank “calculation” page was pre-signed and dated June 10, 2015 when the HPLC test was performed. C) During our inspection of your finished API Quality Control Laboratory on June 17, 2015, we found that an analyst had set up microbiology testing for finished dosage Injection (for domestic market) and Water. Culture plates will be monitored for bacteria growth starting June 18 for © The testing report, however, was signed on June 17; before completing this testing.

  3. 3

    Deviations not adequately investigated

    OBSERVATION 3 Deviations from critical control points are not investigated. Specifically, from 01/2013 to 08/2013, your firm initiated a total of 7 deviation investigations regarding Be © excursions during Oot API. This limit is considered a critical control point. Our review of the 7th deviation found that your tirm had concluded no further deviation investigations were necessary regarding excursions during “ue to a historical data review demonstrating that 27 previously manutactured batches (01/2012 to 06/2013) had met the final release specifications. SOP-PMP310010-2 "Disposing Procedure for Abnormal Events" was revised on 08/27/13 to reflect this change. However, this © @limit is still considered a critical control point within your written procedures, and no further studies (e.g. stability) or other scientific justification are available to support a lack of investigation.

  4. 4

    Control software validation deficiencies

    OBSERVATION 4 There is no assurance that software used to control critical processing equipment is capable of meeting user requirements for data security. Specifically, during our review of the validation package for the. ©, oftware used to control your ©3001, we found the following deficiencies: A) There is no written document describing the User Requirement Specifications (URS) B) There are a total of three common login IDs (Admin, Manager, Operator) with various access levels. There are no unique usernames/passwords established. There is no written procedure to define the access level (e.g. ability to alter recipe) for each of the three login IDs. C) The validation package was written, performed, and reviewed by a third party contractor. There is no evidence that the validation was reviewed by your Quality Unit and deemed acceptable.

  5. 5

    Electronic records not adequately maintained

    OBSERVATION 5 Electronic records are not adequately maintained, archived and retrieved. Specifically, . : (0) (4) A) The electronic raw data for your ©®@p3001 and D3002, controlled using the and 5h software, respectively, is transferred onto a USB drive and then to another desktop for archival. After transferring to this second desktop, the original electronic data on the first desktop and USB drive are deleted. There are no written procedures for electronic data retention, transferring, and archiving in order to ensure data security. B) For the electronic raw data transfer process described above, there is and has been no verification step to ensure the accuracy and completeness of the transfer. Furthermore, for review, the data must be re-copied and transferred (using the USB drive) back to the original desktop with the appropriate software, and is not readily retrievable for evaluation.

  6. 6

    Critical parameters not monitored

    OBSERVATION 6 Critical control parameters are not adequately monitored and controlled. Specifically, . (0) (4) A) Our review of restored ©“ data for Batch No. © found that the run parameters including ©@and| ~~ ®@were not recorded for the time period from 13:28:37 to 15:08:37, May 29, 2015. No deviation was documented; no root cause was identified, and no investigation was conducted. B) During this © “process, there were 20 alarms generated including two FV29 chamber inlet valve 1 failures. There are no written procedures in place to define the significance of alarms. When questioned, the responsible operator was unable to define the significance of alarms generated during manufacturing operations.

  7. 7

    Laboratory electronic raw data not controlled

    OBSERVATION 7 Laboratory electronic raw data is not controlled and protected. Specifically, during our review of the electronic potency raw data for collected using the ZY-3001V Multifunction Microbiology Analyzer, we noted the following deficiencies regarding data security: A) There is no provision in place to create raw data records for each analysis performed. Test results are required to be saved manually. B) There are no individual user names/passwords configured. All analysts use a common login ID/password. . . ©) C) There are no controls in place to prevent data from being deleted between the server back-ups.

  8. 8

    Inadequate washing/toilet facilities

    OBSERVATION 8 Adequate washing and toilet facilities are not provided. Specifically, during our inspection of the area within unit #™" we found there was no soap available at the entrance hand-washing station. Soap is required to be used per your posted entrance instructions.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

  • Warning LetterAug 4, 2016CDER · 413 days after this inspection ended

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.