Skip to content

Zhejiang Medicine Co. Ltd. Xinchang Pharmaceutical Factory

98 East Xinchang Dadao Road, Xinchang, China

FEI 3003631275DUNS 654035922

FDA has 7 inspections on file for Zhejiang Medicine Co. Ltd. Xinchang Pharmaceutical Factory in Xinchang, China (FEI 3003631275), from 2009 to 2025. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued.

The most recent OAI inspection ended on Jun 18, 2015. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and API manufacturing, through Dec 31, 2026. Its registrant is Zhejiang Medicine Co., Ltd. Xinchang Pharmaceutical Factory (D-U-N-S 654035922).

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
7, 2009–2025
1 OAI · 4 VAI · 2 NAI
Inspections with 483 observations shown
1 of 7
Form 483s posted by FDA
↗
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  4. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Laboratory control procedures not followed

      OBSERVATION 1 Laboratory control procedures are not followed. Specifically, during our review of your firm's Quality Control laboratory electronic chromatography data, we identified significant deviations from your laboratory control procedures. Our review found that samples are pre-tested multiple times prior to performing the official/reported analysis. This trial analysis data was performed and saved within your auxiliary "R&D" project folders. All raw data (e.g. sample weight/dilutions) pertaining to these trial sample analyses are discarded. Our review of the historical data collected for residual solvent by GC testing of OAPI identified what appear to be potentially significant differences between the trial and official results, including sample results that appear to include unknown peaks, which may cause the batches to be considered out-of-specification. However, due to the lack of supporting raw data (e.g. sample weights/dilutions), an accurate calculation of the residual solvent levels was not possible. Notably, your firm has initiated a total of 1 OOS investigation (including raw materials, in-process and finished products) since 01/2013 deemed to be due to laboratory error. For example: (b) (4) ©) (4) A) API batch # - The initial trial sample analysis was performed on 05/01/13 starting at 11:10am - The second trial sample analysis was performed on 05/03/13 starting at 10:31am - The official/reported analysis was performed on 05/03/13 starting at Be (b) (4) . B) “API batch - The initial trial sample analysis was performed on 06/18/13 starting at 9:52am - The second trial sample analysis was performed on 06/18/13 starting at 3:23pm - The official/reported analysis was performed on 06/18/13 starting at Be C) ©) “apr batch 4 (b) (4) - A trial sample analysis was performed on 04/22/13 starting at 9:52am - The official/reported analysis was performed on 04/23/13 starting at BE D) ©® 4 pI batch # ®@ - A trial sample analysis was performed on 06/13/13 starting at 10:07am - The official/reported analysis was performed on 06/13/13 starting at El ©) 4) E) API batch # Ee - The initial trial sample analysis was performed on 04/22/13 starting at 12:26pm - The second trial sample analysis was performed on 04/22/13 starting at 4:00pm - The official/reported analysis was performed on 04/22/13 starting at Be

    2. Observation 2

      QC records not documented contemporaneously

      OBSERVATION 2 QC Laboratory records are not documented contemporaneously. Specifically, A) During our inspection of your finished API Quality Control Laboratory on June 15, 2015, we observed that a QC analyst pasted balance weighing slips, which were generated on June 11, 2015, onto the “Testing Original Records of®@ DS” worksheet (Lot #: 9 and signed her name and back dated as June 11, 2015. B) During our inspection of your finished API Quality Control Laboratory on June 15, 2015, we observed an analyst performing a calculation for “SST Record for HPLC Analysis of (USP)- Chromatographic Purity” based on the HPLC test data generated on June 10, 2015. However, the blank “calculation” page was pre-signed and dated June 10, 2015 when the HPLC test was performed. C) During our inspection of your finished API Quality Control Laboratory on June 17, 2015, we found that an analyst had set up microbiology testing for finished dosage Injection (for domestic market) and Water. Culture plates will be monitored for bacteria growth starting June 18 for © The testing report, however, was signed on June 17; before completing this testing.

    Show observations 3 to 8
    1. Observation 3

      Deviations not adequately investigated

      OBSERVATION 3 Deviations from critical control points are not investigated. Specifically, from 01/2013 to 08/2013, your firm initiated a total of 7 deviation investigations regarding Be © excursions during Oot API. This limit is considered a critical control point. Our review of the 7th deviation found that your tirm had concluded no further deviation investigations were necessary regarding excursions during “ue to a historical data review demonstrating that 27 previously manutactured batches (01/2012 to 06/2013) had met the final release specifications. SOP-PMP310010-2 "Disposing Procedure for Abnormal Events" was revised on 08/27/13 to reflect this change. However, this © @limit is still considered a critical control point within your written procedures, and no further studies (e.g. stability) or other scientific justification are available to support a lack of investigation.

    2. Observation 4

      Control software validation deficiencies

      OBSERVATION 4 There is no assurance that software used to control critical processing equipment is capable of meeting user requirements for data security. Specifically, during our review of the validation package for the. ©, oftware used to control your ©3001, we found the following deficiencies: A) There is no written document describing the User Requirement Specifications (URS) B) There are a total of three common login IDs (Admin, Manager, Operator) with various access levels. There are no unique usernames/passwords established. There is no written procedure to define the access level (e.g. ability to alter recipe) for each of the three login IDs. C) The validation package was written, performed, and reviewed by a third party contractor. There is no evidence that the validation was reviewed by your Quality Unit and deemed acceptable.

    3. Observation 5

      Electronic records not adequately maintained

      OBSERVATION 5 Electronic records are not adequately maintained, archived and retrieved. Specifically, . : (0) (4) A) The electronic raw data for your ©®@p3001 and D3002, controlled using the and 5h software, respectively, is transferred onto a USB drive and then to another desktop for archival. After transferring to this second desktop, the original electronic data on the first desktop and USB drive are deleted. There are no written procedures for electronic data retention, transferring, and archiving in order to ensure data security. B) For the electronic raw data transfer process described above, there is and has been no verification step to ensure the accuracy and completeness of the transfer. Furthermore, for review, the data must be re-copied and transferred (using the USB drive) back to the original desktop with the appropriate software, and is not readily retrievable for evaluation.

    4. Observation 6

      Critical parameters not monitored

      OBSERVATION 6 Critical control parameters are not adequately monitored and controlled. Specifically, . (0) (4) A) Our review of restored ©“ data for Batch No. © found that the run parameters including ©@and| ~~ ®@were not recorded for the time period from 13:28:37 to 15:08:37, May 29, 2015. No deviation was documented; no root cause was identified, and no investigation was conducted. B) During this © “process, there were 20 alarms generated including two FV29 chamber inlet valve 1 failures. There are no written procedures in place to define the significance of alarms. When questioned, the responsible operator was unable to define the significance of alarms generated during manufacturing operations.

    5. Observation 7

      Laboratory electronic raw data not controlled

      OBSERVATION 7 Laboratory electronic raw data is not controlled and protected. Specifically, during our review of the electronic potency raw data for collected using the ZY-3001V Multifunction Microbiology Analyzer, we noted the following deficiencies regarding data security: A) There is no provision in place to create raw data records for each analysis performed. Test results are required to be saved manually. B) There are no individual user names/passwords configured. All analysts use a common login ID/password. . . ©) C) There are no controls in place to prevent data from being deleted between the server back-ups.

    6. Observation 8

      Inadequate washing/toilet facilities

      OBSERVATION 8 Adequate washing and toilet facilities are not provided. Specifically, during our inspection of the area within unit #™" we found there was no soap available at the entrance hand-washing station. Soap is required to be used per your posted entrance instructions.

  5. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  7. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, API manufacturing
Registration runs through
Dec 31, 2026
Registrant
Zhejiang Medicine Co., Ltd. Xinchang Pharmaceutical FactoryD-U-N-S 654035922

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3003631275 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3003631275. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.