Sekisui Medical Co., Ltd.

Dai 4 Chiwari Chiwari Chiwari 115, Matsuo, Hachimantai, Japan

FEI 3002806840DUNS 695615716

FDA has 5 inspections on file for Sekisui Medical Co., Ltd. in Hachimantai, Japan (FEI 3002806840), from 2011 to 2025. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued.

The most recent OAI inspection ended on Jun 17, 2016. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, packing and analysis, through Dec 31, 2026. Its registrant is Sekisui Medical Co., Ltd. (D-U-N-S 695615716).

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
5, 2011–2025
1 OAI · 1 VAI · 3 NAI
Inspections with 483 observations shown
1 of 5
Form 483s posted by FDA
↗
Requested under FOIA
2 requests, latest Jan 14, 2026
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  2. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  3. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  4. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 10 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Raw data deletion and missing records

      Failure to maintain and review all raw data. 1. Until 06 June 2016, procedures did not require that all raw data be maintained. Only reported data was maintained. Analysts deleted or did not submit test data that would not be reported. This was done without oversight. Review of electronic files from the HPLC and GC computers found the presence of hundreds of deleted or unreported chromatograms. Deleted files were also observed on the IR-3 system. Examples of deleted or unused chromatograms included: a. The computer for GC-4 and GC-6 had deleted individual chromatogram files and deleted folders containing sequences with associated chromatograms in the "Recycle Bin". Deleted data for testing of lot" as part of sequence 150909 was restored. It showed an original sequence with 11 injections from 09-10 September 2015. These were deleted on 31 May 2016 without any documented reason. A new sequence for the same lots was repeated on 11 September 2015 and the data was used to report results. b. P@ testing of batch ‘was started on 28 February 2014 on HPLC 16. The duplicate injections showed a differing peak appearance. The test was repeated again on 02 March 2014, which showed additional abnormal peak appearance. Testing was repeated a third time on 03 March 2014 and instead performed on HPLC 15 with conforming results. Only the data from the third test was reported. c. In sequences 160309 and 160115 on HPLC 16, individual chromatograms were deleted and then replaced with new chromatograms with the same name as the original file. 2. No raw data could be provided to support the recovery method of the cleaning validation sampling method for b) 4) 3. Complete raw data relating to sample preparation times, weights, media lot numbers, and incubators used were not maintained for the microbial testing and endotoxin testing performed during cleaning validation of(s) b)#)

    2. Observation 2

      Inadequate electronic data access controls

      Failure to prevent unauthorized access of changes to data and to provide adequate controls to prevent omissions of data. 1. Electronic GC chromatography data from GC-7, collected prior to March 2016, was not available for review. This instrument was used for release testing of ® and“ , products for the US market. The stand-alone computers associated with the GC were discarded. Data was backed-up onto an external drive, but could not be restored at the time of the inspection. No tests were conducted to verify the back-up process would work prior to disposing of the computers that contained the source raw data. 2. The data back-up process for the standalone HPLC and GC systems does not include back-up of audit trails associated with the analysis. During the inspection the stand-alone computer associated with HPLC-19 was not functional. Audit trail information could not be retrieved from the back-up. 3. Electronic chromatography data is stored on stand-alone systems for seven of the) | HPLCs and one of the PT GCs. There are no controls to prevent deletion of the source data. Analysts reported that they have deleted files directly from the source data on the hard drive of the computer. 4. Only hard copy chromatograms are reviewed. The EZ Chrome generated reports for printing chromatograms are not protected. This software is used for five of the § HPLCs. Analysts can change sample identifications or dates on the chromatograms prior to printing. 5. Chromatograms were reviewed that had no corresponding entries in the audit trail records. For example, analysis performed on 03 March 2014 for 1ot®®" for HPLC 15. The chromatograms are dated 03 March 2014, but there are no entries in the audit trail between 28 February 2014 at 9:27 and 04 March 2014 at 10:09. 6. Audit trail reviews are limited to only checking the audit trail against the written instrument log. 7. Toximaster software is used to collect data for endotoxin testing of finished API samples. The software does not require username/passwords, there are no audit trails, and electronic data can be deleted. 8. Electronic data for FTIR IR-3 was stored on the hard drive of the associated computer. There were no controls to prevent deletion of data and deleted FTIR data was observed in the computer "Recycle Bin". This system that was used until 19 February 2016 and lacked username/passwords and audit trails. 9. The TOC used for testing water conductivity has an audit trail that is archived by the software and then cleared. The laboratory personnel are unable to access the archived audit trail data. During the inspection no audit trail entries prior to 06 June 2016 could be reviewed. 10. Passwords used to access analytical software are assigned by a manager that also knows the analyst’s password.

    Show observations 3 to 10
    1. Observation 3

      Inadequate water system design and monitoring

      Failure to design and monitor the water system to ensure it is suitable for its intended use. Non-sterile APIs manufactured in Plant [illegible] and [illegible] are intended to be used in the preparation of sterile finished dosage products for the US market. [illegible] 1. Dead leg sections of piping, where water remains stagnant for extended periods of time, were observed in the [illegible] water distribution system. a. Below the [illegible] tank VE-320 in Plant [illegible] there is a dead leg section of piping at least [illegible] meters in length. The piping is used to deliver [illegible] water to tank RE-301, used for [illegible] manufacturing. b. Inside of the Plant [illegible] cleanroom, there is a dead leg section of piping approximately [illegible] inches in length in the water distribution system to deliver water to the [illegible] -301. This section of piping never gets sanitized. 2. Monitoring of the water system does not include sampling at all of the use points that deliver water to the production process or for cleaning equipment. Plant [illegible] has [illegible] use points, but only [illegible] are included in the water monitoring sampling plan. There are [illegible] use points in Plant [illegible], but only [illegible] are included in the water monitoring sampling plan. For example, in Plant [illegible] there is no sampling at the point of use for the tank RE-301, at the point of use for the [illegible] tank in the clean room, at the [illegible] -301 inside of the clean room, or at all of the use points in the clean room that supply water for cleaning equipment in the [illegible] steps of the API production. 3. Validation of the water system has never included increased sampling from all points or at frequency more often than times per [illegible] for microbial tests and [illegible] per [illegible] for endotoxin. 4. In the Plant C water system, a leak was observed from the pump at the distribution loop. Beneath this area of the water system there was standing water on 14 June 2016 due to this leak. The leak and standing water were still present on 17 June 2016. 5. In the Plant [illegible] water system, leaks were observed from the pipe taking water from the [illegible] to the holding tank and from the pipe taking water from the holding tank to the distribution loop pump. A leak was also observed from a valve in the use point (point not identified) near the clean room b) (4) 6. During water sampling, samples are taken directly from valves on the loop. During routine use, these valves always have flexible hoses, up to [illegible] meters in length, connected to them. No data has been collected to evaluate whether these hoses affect the quality of the [illegible] water where it is actually used. 7. Permanent piping supplying water from the loop to the tanks in Plant [illegible], which are used for [illegible], are never sanitized. 8. The [illegible] water system is not monitored for objectionable organisms. 9. A city water supply line inside of the clean room was observed to be leaking.

    2. Observation 4

      Ineffective cleaning validation

      Failure to ensure cleaning procedures are effective. 1. Cleaning validation for the equipment used in Plant [illegible] did not include microbiological or endotoxin evaluation. The equipment is used to manufacture for the US market, which is a non-sterile API used for the preparation of sterile finished drug products. The cleaning process includes rinsing with purified water, but no sanitization steps. 2. Maximum campaign lengths for [illegible] have not been established.

    3. Observation 5

      Poor maintenance and cleanliness of equipment

      Equipment is not maintained and cleaned. 1. [illegible]% sheeting is taped to the [illegible] of tanks in the clean room of Plant to protect them from rusting. The [illegible] is left in place during production campaigns. On 14 June 2016 this [illegible] sheeting was observed to hold stagnant water that was [illegible] in color and had suspended solids in it in tank RE-4002. 2. Tape was put over the water lines in the Plant [illegible] clean room to protect the piping from product powder. Deposits of what was identified to be product was observed under this tape on 14 June 2016. 3. Tape is used throughout the clean rooms to make repairs or protect equipment. 4. D9" applied to equipment and surfaces in the clean room is not smooth and cleanable. 5. The floor was not adequately sealed under the recovered receiving tank RE-303 in the Plant clean room. Pieces of the floor were chipping off and could be observed at a floor drain on 14 June 2016. 6. The [illegible] RE-4002 in the clean room of Plant had rust stains.

    4. Observation 6

      Insufficient process validation controls

      Process validation has not demonstrated the process is in a state of control. 1. Process validation studies have not included statistical evaluation of variability within a batch or between batches. Studies have not included statistically sound sampling plans. A [illegible] sample from batch [illegible] is taken during process validation batches. 2. Process reviews lack complete trending of critical testing results and process monitoring results. 3. Actions are not taken to adjust established limits as a result of ongoing process verification. Specifically, acceptable yield ranges do not reflect historical data. As a result, when there are variations in yield results, these are not identified and further investigated.

    5. Observation 7

      Inadequate test method validation and controls

      Failure to establish scientifically sound and appropriate test procedures. 1. The impurity methods used for stability testing of APIs for the US market have not been shown to be stability indicating. For example, [illegible]. No forced degradation studies have been conducted. 2. Total aerobic count and yeast and mold test performed on the finished APIs for the US market have not been validated. 3. Manual integration is commonly used by analysts processing data from the Chromeleon software. There are no procedures to describe when manual integration is permitted, how to perform it, or how it will be reviewed. 4. Only hard copy chromatograms are printed for review. The printed chromatograms do not allow for adequate review of the integration being performed.

    6. Observation 8

      Unidentified chromatographic peaks in APIs

      Failure to ensure the APIs meet established specifications for quality and purity. [illegible] batches with unknown peaks present in the residual solvent chromatograms were released without further investigation. Unidentified peaks were observed with a retention time of approximately [illegible] (3 minutes), in some, but not all batches. For example, review of a sequence performed on 12 April 2016 showed extra peaks at this retention time in approximately 7 of the 20 batches tested. An additional peak present with a retention time of approximately [illegible] minutes is present at varying levels in all batches. This peak has not been identified and is not described in the impurity profile.

    7. Observation 9

      No established impurity profiles

      Failure to establish impurity profiles. Complete impurity profiles have not been established for the US market API products.

    8. Observation 10

      Uncontrolled issuance of GMP documents

      Failure to establish a system to control the issuance of documents. The production department prints blank copies of GMP forms, including batch records. The laboratory department prints analytical worksheets for documenting analyses. Issuance, use, and reconciliation of these GMP records are not documented.

  5. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on Jan 14, 2026. Each one asked for a Form 483.

  • Inspection date not given

    2 requests. FDA released records in answer to a request for its Form 483 on Jan 15, 2026. FDAgent holds no copy that FDA posted.

    1. Jan 14, 2026FDA-FOIA-2026-409Form 483· 1 of 3 sitesRecords released
    2. Jan 11, 2026FDA-FOIA-2026-320Form 483Records released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing, packing, analysis
Registration runs through
Dec 31, 2026
Registrant
Sekisui Medical Co., Ltd.D-U-N-S 695615716

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3002806840 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3002806840. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.