Laboratory controls in FDA Form 483 observations

Quality control laboratories: test methods and their validation, laboratory records and equipment, reference standards and chromatography. FDAgent finds 304 such observations in 172 Form 483s issued to 163 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
304
Each quoted below
Form 483s
172
Posted by FDA
Facilities
163
Distinct FEIs
Most recent
Sep 3, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 76 in 2026

Laboratory controls observations in Form 483s by inspection year
YearObservations
20081
20090
20100
20110
20128
20130
20145
20154
201613
201721
201823
201914
20200
20216
202218
202342
202425
202548
202676

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.16021 CFR 211.16521 CFR 211.16621 CFR 211.16721 CFR 211.17021 CFR 211.17321 CFR 211.176

The same entries the laboratory controls topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“laboratory control*” · “laboratory record*” · “laboratory investigation*” · “laboratory equipment” · “laboratory instrument*” · “laboratory data” · “laboratory test*” · “laboratory result*” · “laboratory analyst*” · “laboratory procedure*” · “laboratory notebook*” · “laboratory error*” · “QC laborator*” · “quality control laborator*” · “test method*” · “analytical method*” · “analytical procedure*” · “method validation” · “HPLC*” · “chromatograph*” · “reference standard*” · “system suitability” · “method transfer”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 304 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. Torrent Pharmaceuticals LimitedInspection ended Apr 28, 2017 · FEI 3005029956 · Observation 3

    Laboratory equipment used for analytical testing was used outside of the calibrated range. Specifically, the HPLCs, GCs and dissolution units located in the API, formulation (finished dosage form) and stability sample quality control testing laboratories were used outside of the calibrated range. For example: a. SOP No.: IPQC-124-02, Annexure VIII, titled "Wavelength Accuracy Check" states that wavelength accuracy for HPLCs should be calibrated …

    Contains “laboratory equipment”Read the Form 483 →

  2. Torrent Pharmaceuticals LimitedInspection ended Apr 28, 2017 · FEI 3005029956 · Observation 4

    Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, during the establishment of system suitability for chromatographic analyses, the firm did not prepare or use a second working standard solution (Check Standard Solution) to confirm the potency, accuracy and purity …

    Opens with FDA's citation wording for 21 CFR 211.160(b)Read the Form 483 →

  3. Dr. Reddy's Laboratories Unit 6Inspection ended Apr 4, 2017 · FEI 3002949085 · Observation 1

    Complete records are not always maintained for periodic calibration of laboratory instruments, apparatus, gauges, and recording devices. [For all High Performance Liquid Chromatography systems (HPLC), the firm failed to monitor the lamp hours of their UV detectors. In addition, monitoring of the QC laboratory’s HPLC units does not include a periodic check of the hours of the UV-Vis lamps after 2000 hours of operation as recommended by the …

    Contains “laboratory instrument*”Read the Form 483 →

  4. Dr. Reddy's Laboratories Unit 6Inspection ended Apr 4, 2017 · FEI 3002949085 · Observation 2

    Laboratory records do not include a complete record of all data secured in the course of each test, including all chromatograms from laboratory instrumentation, properly identified to show the specific components of the drug substance tested. Specifically, laboratory records do not always contain the HPLC standard and sample chromatograms. For example, the laboratory records for USP Batch [illegible] manufactured 2/25/2017, [illegible] …

    Contains “laboratory record*”Read the Form 483 →

  5. Meridian Medical Technologies, Inc. a Pfizer CompanyInspection ended Mar 24, 2017 · FEI 1950222 · Observation 8

    … The test methods for design verification testing are inadequate. (b) (4) of the final product is not done (b) (4) prior to functional verification testing according to your document PR-14719 titled 'Final Report - Component and Functional Qualification of the NGA EpiPen Sr. Auto-Injector using (b) (4) Plungers from (b) (4)' for the (b) (4). The same is true for the completed verification testing of the EpiPen and EpiPen Jr. products. C. …

    Contains “test method*”Read the Form 483 →

  6. Meridian Medical Technologies, Inc. a Pfizer CompanyInspection ended Mar 24, 2017 · FEI 1950222 · Observation 10

    Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling and drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, we witnessed functionality testing of EpiPen and observed the following: A. The lot …

    Opens with FDA's citation wording for 21 CFR 211.160(b)Read the Form 483 →

  7. Dr. Reddy's LaboratoriesInspection ended Feb 21, 2017 · FEI 3005447965 · Observation 1

    The specificity of test methods has not been established. Specifically, A. Your firm failed to perform the stress (forced degradation) studies for the ®® USP non-compendia optical purity test by HPLC analytical test method during the test method validation. The validation number 20 EAiVIVA 002, dated 06/26/2002 does not contain the specificity/selectivity studies necessary to demonstrate the suitability and adequacy of the analytical test method …

    Contains “test method*”Read the Form 483 →

  8. Dr. Reddy's LaboratoriesInspection ended Feb 21, 2017 · FEI 3005447965 · Observation 2

    Procedures describing the calibration of instruments are deficiently written or followed. Specifically, a) The calibration of the Gas Chromatographic (GC) instruments was incomplete. The review of the ®@ Operational Calibration for the Agilent GC/Headspace (GC/HS) QC-206, conducted by the outside contractor and as in-house calibration, did not include the HS oven temperature, noise and drift, signal to noise and detector accuracy tests as part of …

    Contains “chromatograph*”Read the Form 483 →

  9. Dr. Reddy's LaboratoriesInspection ended Feb 21, 2017 · FEI 3005447965 · Observation 3

    Records maintained of any modification of an established method employed in testing do not include the reason for the modification, the data to verify that the modification produced results that are at least as accurate and reliable for the material being tested as the established method. Specifically, Your firm failed to follow the USP monograph identification test method for the Ultraviolet Absorption <197U> that defined how to perform the test …

    Contains “test method*”Read the Form 483 →

  10. Bayer AG PharmaInspection ended Jan 20, 2017 · FEI 3002806462 · Observation 4

    … Paper shredders are present in the QC laboratory and production area offices.

    Contains “QC laborator*”Read the Form 483 →

  11. Bayer AG PharmaInspection ended Jan 20, 2017 · FEI 3002806462 · Observation 7

    … The standards passed system suitability and no limits had been established for retention time drift. No evaluation of previous analytical runs, which also showed retention time drifts, including sample set (b) (4) (b) (4) were performed. Additionally, no limits were established for acceptable retention time drift.

    Contains “system suitability”Read the Form 483 →

  12. Bayer AG PharmaInspection ended Jan 20, 2017 · FEI 3002806462 · Observation 9

    Failure to maintain and review all analytical data. 1. Until June 2016, analysts performed HPLC injections identified as "test" or other similar names and injections with no sample name at all. The content of these injections and their purpose were not documented and were never reviewed. For example, review of the 2015 project folder for assay and impurity testing of (b) (4) (b) (4) Tablet show that out of (b) (4) total injections, approximately …

    Contains “HPLC*”Read the Form 483 →

  13. Bayer AG PharmaInspection ended Jan 20, 2017 · FEI 3002806462 · Observation 10

    Test procedures for analytical testing have not been established. 1. No procedures have been established to review audit trails for the laboratory software systems. Examples include, but are not limited to, Empower (Chromatography), Opus (IR Spectroscopy), and Disso Net (Dissolution by UV). 2. Manual integration of chromatograms is permitted. Procedures describing when manual integration can be performed, how it is to be performed, and how it …

    Contains “chromatograph*”Read the Form 483 →

  14. Zhejiang Huahai Pharmaceutical Co. Ltd.Inspection ended Nov 18, 2016 · FEI 3003999190 · Observation 2

    OBSERVATION #2 Failure to establish laboratory controls that include scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality, and purity. 1. Assessments to establish environmental monitoring sampling points were not comprehensive. For example, they did not evaluate expanded sampling points or thoroughly …

    Contains “laboratory control*”Read the Form 483 →

  15. Sun Pharmaceuticals Industries, Inc.Inspection ended Nov 16, 2016 · FEI 3002807979 · Observation 1

    … The laboratory investigation revealed no laboratory error after sample re-analysis. A full investigation was done in production and a non-assignable cause was identified. The batches associated with the event were released to the market in the month of March 2016. The impurity specification of CONMT® “yy for finished dosage form was changed in line with the EP pharmacopeia specification @ “hy tor © AP] after these OOS results were obtained to …

    Contains “laboratory investigation*”Read the Form 483 →

  16. Sun Pharmaceuticals Industries, Inc.Inspection ended Nov 16, 2016 · FEI 3002807979 · Observation 2

    Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards. Specifically, There is a failure to document repeat testing in the laboratory equipment logbook when samples are reanalyzed from the same sample preparation vial. On October 29, 2016, raw material batch (BX was tested twice for “and © “Bement via Atomic Absorption Spectrometry …

    Contains “laboratory record*”Read the Form 483 →

  17. Sun Pharmaceuticals Industries, Inc.Inspection ended Nov 16, 2016 · FEI 3002807979 · Observation 3

    … Laboratory analysts have the ability to change instrument settings including date and time on the instrument.

    Contains “laboratory analyst*”Read the Form 483 →

  18. Aurobindo Pharma Limited Unit 4Inspection ended Sep 16, 2016 · FEI 3008461619 · Observation 2

    Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that conform to appropriate standards of identity, strength, quality and purity. Specifically, your written test procedures for assay and related substances for all sterile injectable drug products intended for the US market utilize (b) (4) of (b) (4) unit containers in sample preparation (b) (4) HPLC analysis with the …

    Opens with FDA's citation wording for 21 CFR 211.160(b)Read the Form 483 →

  19. Aurobindo Pharma Limited Unit 4Inspection ended Sep 16, 2016 · FEI 3008461619 · Observation 4

    The use of instruments and recording devices not meeting established specifications was observed. Specifically, the "Indu Softweb Studio" SCADA electronic recording system for temperatures found in the micro lab rooms for incubating Environmental Monitoring, Reference Cultures, and other media incubation shows multiple out-of-specification temperatures and loss of communication errors through June, July, and August 2016. As evidenced by repeated …

    Opens with FDA's citation wording for 21 CFR 211.160(b)(4)Read the Form 483 →

  20. Claris Injectables LimitedInspection ended Aug 26, 2016 · FEI 3004610460 · Observation 2

    OBSERVATION 2 Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet appropriate statistical quality control criteria as a condition for their approval and release. Specifically, samples collected for BET testing, per SOP # W/QAD/032, titled, "Finished Product Sampling", are not collected in sufficient quantity to be representative of the final batch.

    Opens with FDA's citation wording for 21 CFR 211.165(d)Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about laboratory controls in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.