Laboratory controls in FDA Form 483 observations
Quality control laboratories: test methods and their validation, laboratory records and equipment, reference standards and chromatography. FDAgent finds 304 such observations in 172 Form 483s issued to 163 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 304
- Each quoted below
- Form 483s
- 172
- Posted by FDA
- Facilities
- 163
- Distinct FEIs
- Most recent
- Sep 3, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 76 in 2026
| Year | Observations |
|---|---|
| 2008 | 1 |
| 2009 | 0 |
| 2010 | 0 |
| 2011 | 0 |
| 2012 | 8 |
| 2013 | 0 |
| 2014 | 5 |
| 2015 | 4 |
| 2016 | 13 |
| 2017 | 21 |
| 2018 | 23 |
| 2019 | 14 |
| 2020 | 0 |
| 2021 | 6 |
| 2022 | 18 |
| 2023 | 42 |
| 2024 | 25 |
| 2025 | 48 |
| 2026 | 76 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
21 CFR 211.16021 CFR 211.16521 CFR 211.16621 CFR 211.16721 CFR 211.17021 CFR 211.17321 CFR 211.176
The same entries the laboratory controls topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“laboratory control*” · “laboratory record*” · “laboratory investigation*” · “laboratory equipment” · “laboratory instrument*” · “laboratory data” · “laboratory test*” · “laboratory result*” · “laboratory analyst*” · “laboratory procedure*” · “laboratory notebook*” · “laboratory error*” · “QC laborator*” · “quality control laborator*” · “test method*” · “analytical method*” · “analytical procedure*” · “method validation” · “HPLC*” · “chromatograph*” · “reference standard*” · “system suitability” · “method transfer”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 304 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
ARL Biopharma, Inc. dba Analytical Research LaboratoriesInspection ended Nov 8, 2012 · FEI 3003644883 · Observation 3
3. Your firm states on the Microbiology Report that is issued to a client after endotoxin testing that the Test Method employed was USP <85>. Your firm is not fully following all parts of USP <85> when performing endotoxin testing of human drug products. Specifically, the Maximum Valid Dilution (MVD) is not always calculated using the formula in USP <85>. Your firm does not ensure that each of your clients provides information regarding dosing of …
Contains “test method*”Read the Form 483 →
Hospira Inc.Inspection ended Oct 24, 2012 · FEI 1925262 · Observation 2
Investigations of an unexplained discrepancy did not extend to other drug products that may have been associated with the specific failure or discrepancy. Specifically, 1. Since March 2012 your firm has discovered 2 lots [illegible] of Fentanyl Citrate for injection which failed HPLC stability time point analysis for total impurities. Subsequent investigation of the failures [illegible] were due to extractables from the rubber plunger. In …
Contains “HPLC*”Read the Form 483 →
C.A.T. Gmbh and Co. KGInspection ended Mar 20, 2012 · FEI 3004422881 · Observation 1
OBSERVATION 1 The establishment of test procedures and laboratory control mechanisms including any changes thereto, are not drafted by the appropriate organizational unit and reviewed and approved by the quality control unit. Specifically, USP <621> Chromatography states that system suitability tests are an integral part of gas and liquid chromatographic methods which verify that the system is adequate for the intended analysis. It states that …
Opens with FDA's citation wording for 21 CFR 211.160(a)Read the Form 483 →
Genzyme CorporationInspection ended Oct 10, 2008 · FEI 1000305672 · Observation 9
On 9/17/08 rouging was seen on the outside of the chromatography column. Internal surfaces and manual valves on the stainless steel chromatography columns used during drug substance purification are not adequately maintained. In January 2008 the facilities [illegible] chromatography skid maintenance SOP was updated [illegible] with instructions for such maintenance. Performance of this maintenance is dependent on manufacturing requesting the …
Contains “chromatograph*”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.160General requirementsIn this theme's rule40
- 21 CFR 211.165Testing and release for distributionIn this theme's rule24
- 21 CFR 211.166Stability testingIn this theme's rule21
- 21 CFR 211.194Laboratory records17
- 21 CFR 211.192Production record review15
- 21 CFR 211.22Responsibilities of quality control unit12
- 21 CFR 211.167Special testing requirementsIn this theme's rule6
- 21 CFR 211.170Reserve samplesIn this theme's rule6
- 21 CFR 211.68Automatic, mechanical, and electronic equipment5
- 21 CFR 211.110Sampling and testing of in-process materials and drug products3
Ask FDAgent about laboratory controls in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
- Laboratory controls: FDA's Form 483 citations of the same 21 CFR entries
- Aseptic processing: FDA's Form 483 citations of overlapping 21 CFR entries
- Stability: FDA's Form 483 citations of overlapping 21 CFR entries
- Every Form 483 theme, with its counts
- What a Form 483 is, and the latest 483s
- Every 21 CFR section in FDA's Form 483 citations
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.