Skip to content

Laboratory controls in FDA Form 483 observations

Quality control laboratories: test methods and their validation, laboratory records and equipment, reference standards and chromatography. FDAgent finds 304 such observations in 172 Form 483s issued to 163 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
304
Each quoted below
Form 483s
172
Posted by FDA
Facilities
163
Distinct FEIs
Most recent
Sep 3, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 76 in 2026

Laboratory controls observations in Form 483s by inspection year
YearObservations
20081
20090
20100
20110
20128
20130
20145
20154
201613
201721
201823
201914
20200
20216
202218
202342
202425
202548
202676

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.16021 CFR 211.16521 CFR 211.16621 CFR 211.16721 CFR 211.17021 CFR 211.17321 CFR 211.176

The same entries the laboratory controls topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“laboratory control*” · “laboratory record*” · “laboratory investigation*” · “laboratory equipment” · “laboratory instrument*” · “laboratory data” · “laboratory test*” · “laboratory result*” · “laboratory analyst*” · “laboratory procedure*” · “laboratory notebook*” · “laboratory error*” · “QC laborator*” · “quality control laborator*” · “test method*” · “analytical method*” · “analytical procedure*” · “method validation” · “HPLC*” · “chromatograph*” · “reference standard*” · “system suitability” · “method transfer”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 304 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. RC Outsourcing LLCInspection ended Sep 3, 2026 · FEI 3011967886 · Observation 6

    Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, Your firm continues to fail to provide a scientific rationale to support the established method and limits for subvisible particle testing of Avastin (bevacizumab) 1.75 mg/0.07 mL for intravitreal injection. Your …

    Opens with FDA's citation wording for 21 CFR 211.160(b)Read the Form 483 →

  2. OPS International Inc dba Olympia PharmaceuticalsInspection ended Sep 3, 2026 · FEI 3009724085 · Observation 5

    The written stability program for drug products does not include reliable, meaningful and specific test methods. Specifically, your firm assigns a (b)(4) beyond-use date (BUD) to Sermorelin Acetate 0.9 mg/mL Injection based on your contract laboratory stability study. However, your firm failed to provide adequate demonstration that the analytical procedure can detect relevant degradation-related changes. Your method validation report for …

    Opens with FDA's citation wording for 21 CFR 211.166(a)(3)Read the Form 483 →

  3. TAILSTORM HEALTH INCInspection ended Aug 28, 2026 · FEI 3015929581 · Observation 5

    Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, Growth Media A. QC microbiology personnel use Standard Methods (b) (4) (Plate Count (b) (4)) for all (b) (4) bioburden samples. There is inadequate …

    Opens with FDA's citation wording for 21 CFR 211.160(b)Read the Form 483 →

  4. STAQ Pharma of Ohio LLCInspection ended Aug 19, 2026 · FEI 3025336457 · Observation 1

    Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, Your firm's visual inspection qualification procedure for sterile injectable drug products compounded and packaged in syringes is inadequate to ensure that visual …

    Opens with FDA's citation wording for 21 CFR 211.160(b)Read the Form 483 →

  5. Carolina Infusion LLCInspection ended Aug 18, 2026 · FEI 3015826782 · Observation 1

    … This is not appropriate for aseptic processing or laboratory testing. The in-house sterility and endotoxin test method development does not evaluate for product interference (e.g., from the use of (b)(4)). This calls into question the validity of your test results.

    Contains “laboratory test*”Read the Form 483 →

  6. OurPharma LLCInspection ended Aug 12, 2026 · FEI 3014064135 · Observation 3

    … of Specification (OOS) SOP), does not establish defined timeframes for the completion of OOS investigations, including maximum allowable durations for Phase I laboratory investigations or Phase II full-scale investigations, nor does it define criteria or approval requirements governing the use of supplemental justifications to extend investigations beyond an initial target. During the inspection, firm management indicated that investigations …

    Contains “laboratory investigation*”Read the Form 483 →

  7. Wanbury LimitedInspection ended Jul 17, 2026 · FEI 3002980818 · Observation 5

    Laboratory records are not accurate and/or complete, and are not reviewed by a second person. Specifically, (b)(4) A) Growth Promotion Test (GPT) results for batch (b)(4) were not recorded, and the analytical data sheet was not completed prior to media release; nevertheless, this media was released and used for finished product microbiological testing. (b)(4) B) Growth Promotion Test (GPT) results for batch (b)(4) medium, in were recorded as …

    Contains “laboratory record*”Read the Form 483 →

  8. Cascade Specialty Pharmacy LLCInspection ended Jul 17, 2026 · FEI 3015133983 · Observation 4

    Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release. Specifically, Your firm performs routine potency testing only on in-process materials for Levothyroxine Sodium and Liothyronine Sodium. Your firm does not perform routine finished product testing on manufactured drug products. For example: A. …

    Opens with FDA's citation wording for 21 CFR 211.165(a)Read the Form 483 →

  9. Cascade Specialty Pharmacy LLCInspection ended Jul 17, 2026 · FEI 3015133983 · Observation 6

    There is no written testing program designed to assess the stability characteristics of drug products. Specifically, Your firm does not have a written stability testing program to determine the beyond use date for each drug product. Your firm assigns beyond use date based on the [(b)(4)], which is based on either stability testing performed by another entity for in-process stock, or based on the dosage form and the storage condition.

    Opens with FDA's citation wording for 21 CFR 211.166(a)Read the Form 483 →

  10. Glenmark Pharmaceuticals LimitedInspection ended Jun 30, 2026 · FEI 3004672766 · Observation 6

    Laboratory records do not include complete data derived from all tests, examinations, and assays necessary to assure compliance with established specifications and standards. Specifically, Your analysts have been granted user privileges within the Empower software that allow them to view numerical results in the review window - including area counts of peaks - while changing processing methods, without requiring the chromatograms to be saved. …

    Contains “laboratory record*”Read the Form 483 →

  11. Auroactive Pharma Private LimitedInspection ended Jun 26, 2026 · FEI 3030708811 · Observation 1

    Laboratory Incident Investigations for High-Performance Liquid Chromatography (HPLC) Injection-to-Injection Area Variability Failures Were Inadequate. Specifically, The firm's Quality Control (QC) laboratory failed to conduct thorough investigations in accordance with SOP QC042 - "Handling of Laboratory Incidents" for the following Laboratory Incident Reports (LIRs): LIR-25-00008, LIR-25-00013, LIR-25-00014, LIR-25-00015, LIR-25-00038, …

    Contains “chromatograph*”Read the Form 483 →

  12. Eugia Steriles Private LimitedInspection ended Jun 19, 2026 · FEI 3027357163 · Observation 4

    … OOS Number ESOOS240002 was initiated for R&D (b)(4) Injection USP (b) mg/Vial, Test: Gross Content by HPLC, Date Initiated: February 03, 2024, Batch No. (b)(4) Results: (b)(4) mg/vial (Specification Limit: NLT (b)(4) and NMT (b)(4)). The manufacturing investigation attributed the most probable root cause to potential issues with connections to vessels during (b)(4) calibration that may not have been accounted for during manufacturing final volume …

    Contains “HPLC*”Read the Form 483 →

  13. Eugia Steriles Private LimitedInspection ended Jun 19, 2026 · FEI 3027357163 · Observation 5

    The reproducibility of test methods have not been established. Specifically, (b)(4) Injection, (b)(4) mg/ml) analytical methods and process was directly transferred from the (b)(4). However, the analytical methods were [illegible]. laboratory came on-site to conduct testing of the homogeneous sample along with an analyst from the receiving laboratory. However, there was no verification or review of the external and operational variables between …

    Opens with FDA's citation wording for 21 CFR 211.165(e)Read the Form 483 →

  14. Jubilant HollisterStier LLCInspection ended Jun 17, 2026 · FEI 3010477 · Observation 5

    The sensitivity of test methods have not been established. Specifically, the sensitivity of test methods has not been established. Bacterial endotoxin testing (BET) samples are inadequately mixed, which may produce results that are not representative. On 06/12/2026 a BET of a (b)(4) sample was observed. The (b)(4) sample was collected on 06/11/2026 from port (b)(4) on the (b)(4)-Loop which supports (b)(4) line. During the testing process it was …

    Opens with FDA's citation wording for 21 CFR 211.165(e)Read the Form 483 →

  15. Jubilant HollisterStier LLCInspection ended Jun 17, 2026 · FEI 3010477 · Observation 6

    Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans designed to assure that components conform to appropriate standards of identity, strength, quality and purity. Specifically, the firm does not test or monitor (b)(4) quality at intermediate (b)(4) steps, (b)(4) (b)(4), or (b)(4) storage tank. The quality unit has not established monitoring for incoming feed (b)(4) quality across key …

    Opens with FDA's citation wording for 21 CFR 211.160(b)Read the Form 483 →

  16. Jubilant HollisterStier LLCInspection ended Jun 17, 2026 · FEI 3010477 · Observation 7

    Established test procedures are not followed. Specifically, your firm conducts reprocessing of laboratory analytical samples without following firm procedures, for example: Bacterial Endotoxin Test: A. On 06/15/2026 I reviewed SOP-001186 (b)(4) Method", revision 22, which describes the in-vitro assay for the detection and (b)(4) quantitation of bacterial endotoxin in (b)(4) drugs or solutions for (b)(4) and other biological products. In …

    Opens with FDA's citation wording for 21 CFR 211.160(a)Read the Form 483 →

  17. Jubilant HollisterStier LLCInspection ended Jun 17, 2026 · FEI 3010477 · Observation 8

    … On 06/17/2026 during discussion with your QC Compliance Scientist of said audit trail protocol for HPLC (b)(4) ((b)(4)) data, it was determined there is no procedure utilized that ensures software specific review is conducted nor that audit trails are conducted in a repeatable manner. SOP-000974 was the only procedure noted as being utilized to conduct said audit trails. Furthermore: A. On 6/16/2026, during discussion of (b)(4) Bacterial …

    Contains “HPLC*”Read the Form 483 →

  18. TOYO Pharmaceutical Co., Ltd.Inspection ended Jun 12, 2026 · FEI 3016419927 · Observation 1

    The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically, On 08 June 2026, I observed the following discrepancies related to documentation in your QC laboratory: Numerous sticky notes containing handwriting in the QC laboratory on desks, computers, shelves, in cabinets, and in drawers. Your firm stated most of the sticky notes were non-GMP in nature, but I observed one sticky …

    Contains “QC laborator*”Read the Form 483 →

  19. TOYO Pharmaceutical Co., Ltd.Inspection ended Jun 12, 2026 · FEI 3016419927 · Observation 3

    Drug product reserve samples are not stored in an immediate container-closure system that has essentially the same characteristics as the marketed product. Specifically, Your firm does not store batches of (b)(4) mg tablet retain samples in the same (b)(4) packaging as you distribute it in. Your firm packs bulk tablets of (b)(4) mg in (b)(4) which is then placed in (b)(4) bottle for shipment. However, your (b)(4) mg tablet retain samples are …

    Opens with FDA's citation wording for 21 CFR 211.170(b)Read the Form 483 →

  20. TOYO Pharmaceutical Co., Ltd.Inspection ended Jun 12, 2026 · FEI 3016419927 · Observation 4

    Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration. Specifically, Your firm does not perform annual visual examination on your retain samples for (b)(4) (b)(4) and (b)(4) mg tablets.

    Opens with FDA's citation wording for 21 CFR 211.170(b)Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about laboratory controls in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.