Records that are incomplete, unprotected or not made at the time: audit trails, deleted or overwritten data, shared logins, uncontrolled forms and backdating. FDAgent finds 120 such observations in 85 Form 483s issued to 84 facilities, for inspections that ended between November 2012 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
120
Each quoted below
Form 483s
85
Posted by FDA
Facilities
84
Distinct FEIs
Most recent
Sep 3, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 49 in 2026

Data integrity observations in Form 483s by inspection year
YearObservations
20121
20130
20140
20154
20168
20175
20189
20194
20200
20211
20227
202312
20248
202512
202649

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.68(b)21 CFR 211.18821 CFR 211.194(a)21 CFR 211.186(a)21 CFR 211.18221 CFR 212.60(g)21 CFR 212.110(b)

The same entries the data integrity topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“data integrity” · “audit trail*” · “backdat*” · “trial injection*” · “test* into compliance” · “contemporaneous*” · “uncontrolled form*” · “uncontrolled blank form*” · “uncontrolled worksheet*” · “uncontrolled record*” · “uncontrolled document*” · “electronic data” · “electronic raw data” · “shared user*” · “shared account*” · “shared login*” · “shared password*” · “user access” · “access privilege*” · “access level*” · “administrator privilege*” · “administrator right*” · “falsif*” · “delet* … data” · “delet* … result*” · “delet* … chromatogram*” · “overwr* … data”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 120 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. FRUEH VERPACKUNGSTECHNIK AGInspection ended Mar 24, 2023 · FEI 3010363503 · Observation 4

    … There is no adequate data integrity program in place to include an adequate review of all electronic data by the Quality Assurance Unit for standalone and network systems, to ensure completeness, consistency, and accuracy of all laboratory and production equipment electronic data generated by your firm. Specifically, per your firm's procedure, (b)(4) This review process does not appear to be adequate, in that all potential data generated during …

    Contains “data integrity”Read the Form 483 →

  2. Lupin Limited Unit 1Inspection ended Nov 23, 2022 · FEI 3002807511 · Observation 2

    Appropriate controls are not exercised over computer or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specially, a. A review of the Sequence Audit trail data for Chromeleon, revealed several examples where your analyst deleted samples and/or blanks from the sequence lists. Your procedure SOP_MDP_QC_013135 (5.0) Assigning User/System Policies and …

    Contains “audit trail*”Read the Form 483 →

  3. Lupin Limited Unit 1Inspection ended Nov 23, 2022 · FEI 3002807511 · Observation 11

    Computer system do not have sufficient controls to prevent unauthorized access or changes to data. Specially, a. During review of the Sequence Audit trail data for Chromeleon, I noted several examples where your analyst deleted samples and/or blanks from the sequence lists. Your procedure SOP_MDP_QC_013135 (5.0) Assigning User/System Policies and Management of Electronic Data in Chromeleon Network (Effective date 13 September 2022) has no …

    Contains “audit trail*”Read the Form 483 →

  4. QuVa Pharma , Inc.Inspection ended Oct 14, 2022 · FEI 3013931875 · Observation 4

    Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, A) During review of user access rights for the (b) (4) (Equipment ID: (b) (4) (b) (4)), in Building (b) (4) which are used to test the (b) (4) of the (b) (4) used to sterilize in process bulk, it was observed that all operators access …

    Opens with FDA's citation wording for 21 CFR 211.68(b)Read the Form 483 →

  5. Medlmmune UK Limited (AstraZeneca/Supply Biologics)Inspection ended Jun 14, 2022 · FEI 3004066112 · Observation 3

    … On 1/17/2019, during the [illegible] of the [illegible] the following failure modes were identified: for the [illegible] - Audit trail did not record the opening of a file for data review. This resulted in no electronic records of reviewer reviewing original data. - Audit trail did not record a [illegible] being read if file was not saved by the analyst. The investigation concluded that there no risk to patients and that there were no product …

    Contains “audit trail*”Read the Form 483 →

  6. Serum Institute of India Pvt. Ltd.Inspection ended Apr 19, 2022 · FEI 3020223359 · Observation 1

    Good Documentation Practices (GDP) and data integrity practices were deficient. Specifically, a) Deviation Report No. M26/06/21/03, dated 6/19/2021, (b)(4) reported that the limit of conductivity for [illegible] was documented as [illegible] instead of [illegible] in the following records: 1) Master Formula Record (MFR) for [illegible] 2) Batch Manufacturing Record (BMR) for [illegible] (BMR no. MBR/ [illegible] 3) SOP for Preparation of …

    Contains “data integrity”Read the Form 483 →

  7. Davis City Pharmacy Inc.Inspection ended Feb 18, 2022 · FEI 3016774626 · Observation 5

    Batch production and control records do not include complete information relating to the production and control of each batch. Specifically, Your firm's production records (formula worksheets) for Benzocaine 20%, Lidocaine 10%, Tetracaine 10% cream, Lot #09302021 and Lot #20101002012022 are deficient because they do not contain the following information: e Order of mixing ingredients e Step by step instructions ® Procedures to ensure proper …

    Opens with FDA's citation wording for 21 CFR 211.188Read the Form 483 →

  8. Bioiberica, S.A.UInspection ended Feb 4, 2022 · FEI 1000418405 · Observation 3

    … During my review of electronic data [illegible] multiple occasions where the sample solution was tested more than [illegible] system suitability specifications. In response, your firm discarded standard preparations and prepared a new sample solution along with a new internal standard solution for testing. Per your firm, a new sample solution is prepared since a new internal standard is also prepared, for both preparations to have (b)(4) …

    Contains “electronic data”Read the Form 483 →

  9. Fujifilm Diosynth Biotechnologies USAInspection ended Apr 21, 2021 · FEI 3000718852 · Observation 9

    You failed to establish procedural controls for your electronic data acquisition systems to ensure that your data records are protected from unauthorized manipulation. For example, a. The SoftMax Pro software (version 5.3 GxP) used to analyze in-process and release samples of commercial and non-commercial products in the QC Laboratories, including Endotoxin testing of (b) (4) (b) (4) allows analysts to save, delete, and rename data files outside …

    Contains “electronic data”Read the Form 483 →

  10. Abilene Nuclear LLC dba National Central PharmacyInspection ended Nov 7, 2019 · FEI 3004819860 · Observation 8

    OBSERVATION 8 The batch production and control records are deficient in that they do not include identification of persons performing and checking each significant step in the operation. Specifically, your firm's production worksheets failed to include a second verifier for critical steps in your pharmacy's production process. For example, in selected production batch records, I found only your firm's pharmacist (the only firm employee) who …

    Opens with FDA's citation wording for 21 CFR 211.188(b)(11)Read the Form 483 →

  11. SCA Pharmaceuticals, Inc.Inspection ended Nov 7, 2019 · FEI 3010683157 · Observation 3

    Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, you have never conducted an audit trail review of the SCANRDI system since you began using it in 2013 for sterility analysis nor do you have a procedure for conducting an audit trail review. Additionally, an employee who performs most of …

    Opens with FDA's citation wording for 21 CFR 211.68(b)Read the Form 483 →

  12. Isorx, Corp.Inspection ended Sep 18, 2019 · FEI 3006624492 · Observation 4

    OBSERVATION 4 Batch production and control records are not prepared for each batch of drug product produced and do not include complete information relating to the production and control of each batch. Specifically, You do not maintain production records for the manufacture of drug products. Also your production records do not include a quality verification that the steps of production have been performed correctly. One example includes 1-123 …

    Opens with FDA's citation wording for 21 CFR 211.188Read the Form 483 →

  13. Rapid Equine Solutions, LLCInspection ended Aug 9, 2019 · FEI 3006708880 · Observation 6

    The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing, processing, packing, and holding. Specifically, your firm uses the (b) (4) computer system to create and maintain production records. Batch templates are printed out and each page is individually placed into plastic zip closure bags for reference during sterile production procedures. …

    Opens with FDA's citation wording for 21 CFR 211.188(b)Read the Form 483 →

  14. Lupin Limited Unit IIIInspection ended Oct 18, 2018 · FEI 3009107538 · Observation 3

    … Your QC reviewer even stated that they do not investigate modifications to the sequence during normal review and accepts the audit trail entry "sequence modified." You stated that the unlocking permissions should be approved by QA and are kept in modified folders for that specific sequence. You failed to provide a copy of a folder for a modified sequence which is approved by QA. When I asked for traceability of the permission records you stated …

    Contains “audit trail*”Read the Form 483 →

  15. Cipla LimitedInspection ended Sep 28, 2018 · FEI 3004081307 · Observation 1

    The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing. Specifically, the proposed commercial master batch record for the production of [illegible] Tablets, [illegible], version 01, does not provide written instructions for the removal of the [illegible] from a [illegible] bag inside your IPCs (In Process Containers) and the subsequent …

    Opens with FDA's citation wording for 21 CFR 211.188(b)Read the Form 483 →

  16. Sun Pharmaceutical Industries LtdInspection ended Aug 31, 2018 · FEI 3002809586 · Observation 1

    Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. For example, electronic data for mg exhibit batch for 0-month stability shows: dissolution at buffer stage L1 was conducted on 9/26/15 with results for the sampling time point at 5 hours, to have a minimum of] Blo release, a …

    Contains “electronic data”Read the Form 483 →

  17. Biotika ASInspection ended Jun 1, 2018 · FEI 3003370212 · Observation 2

    Failure to document changes to computerized systems and provide adequate control to prevent omission or alteration of data. Specifically, a. There is no record of the review audit trails associated with your chromatography data systems used to analyze and to ensure data has not been altered or deleted. SOP 10.36/2017 Ver. 03 effective May 25, 2018 requires the review of audit trails. This procedure lacks details to describe how audit trail review …

    Contains “audit trail*”Read the Form 483 →

  18. Glenmark Pharmaceuticals Ltd.Inspection ended May 24, 2018 · FEI 3008565058 · Observation 3

    … However, during our review of electronic data in the QC laboratory, it was observed that QC managers and the system administrator have the user privilege to “Verify Incomplete Data in Raw Data Files”. Subsequently, we requested your manager to verify the incomplete data and reprocess the injection for both sample sets (two different incidents) and discovered that the injected samples did in fact run, the first incident with approximately ®® …

    Contains “electronic data”Read the Form 483 →

  19. Glenmark Pharmaceuticals Ltd.Inspection ended May 24, 2018 · FEI 3008565058 · Observation 4

    Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, Your firm's manufacturing equipment are not 21 CFR part 11 compliant. For example, A) There are total standalone manufacturing equipment which are not equipped with HMI/PLC/SCADA system. There is no time stamped audit trail, data …

    Opens with FDA's citation wording for 21 CFR 211.68(b)Read the Form 483 →

  20. Glenmark Pharmaceuticals Ltd.Inspection ended May 24, 2018 · FEI 3008565058 · Observation 5

    … "Metadata (data about data)" must be contemporaneously and accurately recorded by permanent means. 2) Your firm maintains a total of document destruction bins at various locations throughout the facility and the documents gets shredded using a shredder located in QA documentation cell and shredder area as per SOP CM/QAO050 "Procedure for disposal of GMP documents by shredding". Your SOP CM/QA050 per ANNEXURE-III allows shredding of investigations …

    Contains “contemporaneous*”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about data integrity in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.