Biotika a.s.
Slovenska Lupca 566, Slovenska Lupca, Slovakia
FEI 3003370212DUNS 643309776
FDA has 3 inspections on file for Biotika a.s. in Slovenska Lupca, Slovakia (FEI 3003370212), from 2012 to 2018. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 2 observations from the PDF; they are listed below. One FOIA request has asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, through Dec 31, 2026. Its registrant is BIOTIKA a.s. (D-U-N-S 643309776).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2012–2018
- 0 OAI · 2 VAI · 1 NAI
- Inspections with 483 observations shown
- 1 of 3
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 1 request, latest Nov 14, 2024
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Incomplete batch record documentation
Completion of significant steps in batch production and control records are not documented. Specifically, A. Fermentation production records do not include complete documentation of in-process test results. For example, i. in-process test results for batch (b) (4) at the fermentation [illegible]. ii. (b) (4) in-process test result for batch (b) (4) in the fermenter at cultivation hour(s) [illegible]. ii. (b) (4) in-process test results for batch (b) (4) in the (b) (4) fermenter at cultivation hour [illegible]. B. Parameters of Class D cleanroom area during sampling of batch were not documented in the batch production record for sampling of product for (b) (4) analysis. For example, i. Differential pressure of the personnel (b) (4), material (b) (4), and (b) (4) area. ii. Relative humidity and temperature of the (b) (4) area. C. Volume of water used to [illegible] and of solution of (b) (4) in storage tank 78301 are not documented in the batch production records for (b) (4).
- Observation 2
Uncontrolled computerized system changes
Failure to document changes to computerized systems and provide adequate control to prevent omission or alteration of data. Specifically, a. There is no record of the review audit trails associated with your chromatography data systems used to analyze and to ensure data has not been altered or deleted. SOP 10.36/2017 Ver. 03 effective May 25, 2018 requires the review of audit trails. This procedure lacks details to describe how audit trail review will be performed and documented. b. Changes to user roles and functions in chromatography data systems are not documented, in that, your QA Manager was added as the System Administrator of the chromatography data system and two QC Analysts were removed as System Administrators. No change control was opened to evaluate the risk of modification to user authorizations.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Nov 14, 2024. It asked for a Form 483.
Inspection ending Jun 1, 2018VAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Nov 14, 2024FDA-FOIA-2024-10123Form 483 + EIRClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing
- Registration runs through
- Dec 31, 2026
- Registrant
- BIOTIKA a.s.D-U-N-S 643309776
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3003370212 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3003370212. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.