The 2 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Incomplete batch record documentation
Completion of significant steps in batch production and control records are not documented. Specifically, A. Fermentation production records do not include complete documentation of in-process test results. For example, i. in-process test results for batch (b) (4) at the fermentation [illegible]. ii. (b) (4) in-process test result for batch (b) (4) in the fermenter at cultivation hour(s) [illegible]. ii. (b) (4) in-process test results for batch (b) (4) in the (b) (4) fermenter at cultivation hour [illegible]. B. Parameters of Class D cleanroom area during sampling of batch were not documented in the batch production record for sampling of product for (b) (4) analysis. For example, i. Differential pressure of the personnel (b) (4), material (b) (4), and (b) (4) area. ii. Relative humidity and temperature of the (b) (4) area. C. Volume of water used to [illegible] and of solution of (b) (4) in storage tank 78301 are not documented in the batch production records for (b) (4).
- 2
Uncontrolled computerized system changes
Failure to document changes to computerized systems and provide adequate control to prevent omission or alteration of data. Specifically, a. There is no record of the review audit trails associated with your chromatography data systems used to analyze and to ensure data has not been altered or deleted. SOP 10.36/2017 Ver. 03 effective May 25, 2018 requires the review of audit trails. This procedure lacks details to describe how audit trail review will be performed and documented. b. Changes to user roles and functions in chromatography data systems are not documented, in that, your QA Manager was added as the System Administrator of the chromatography data system and two QC Analysts were removed as System Administrators. No change control was opened to evaluate the risk of modification to user authorizations.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.