Abilene Nuclear LLC dba National Central Pharmacy
3402 S 14th St, Abilene, Texas, United States
FEI 3004819860
FDA has one inspection on file for Abilene Nuclear LLC dba National Central Pharmacy in Abilene, Texas (FEI 3004819860). It ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 8 observations from the PDF; they are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 1, in 2019
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- ↗
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Exposed skin during aseptic processing
OBSERVATION 1 Personnel engaging in aseptic processing was observed with exposed skin. Specifically, your firm's pharmacy manager was observed during the production of the non-patient specific sterile drug product, EPI-Shugarcaine Su/F Ophth 1 ml/vial, (b)(6), as having his head, partially exposed facial skin, inside LAF Hood.
- Observation 2
Materials not disinfected before entry
OBSERVATION 2 Materials or supplies were not disinfected prior to entering the ISO 5 LAF Hood. Specifically, your pharmacy manager failed to adequately disinfect materials transferred from the ISO 7 Cleanroom into LAF Hood which was later used in production. For example, on 10/30/2019, I observed your pharmacy [illegible] 'Office Use Only', EPI-Shugarcaine Su/F Ophth 1 ml/vial, 11/13/2019. While producing this lot of sterile drug product, I observed the following items were not disinfected prior to entering the ISO 5 LAF Hood. A. During setup for production, your pharmacy placed ampules of Lidocaine 4% Pres-Free [illegible] removed from the non-disinfected tray and disinfected once inside the LAF Hood. B. Your firm's pharmacy manager was observed placing a non-disinfected light green plastic container used to hold the vials into the ISO 5 LAF hood for the purpose of [illegible].
Show observations 3 to 8
- Observation 3
Gloved hands not disinfected/replaced
OBSERVATION 3 Personnel touched equipment or other surfaces located outside the ISO 5 area with gloved hands and then engaged in aseptic processing without changing or sanitizing gloves. Specifically, your firm's pharmacy failed to disinfect sterile gloves prior to re-entry into ISO 5 LAF hood while aseptically processing the sterile drug product, EPI-Shugarcaine Su/F Ophth 1 ml/vial. After collecting additional supplies in the ISO 7 Cleanroom too many times to count, during aseptic processing, I observed your firm's pharmacy manager pick paper from a trashcan, and return into the ISO 5 LAF hood without disinfecting and/or changing the sterile gloves prior to re-entry into the ISO 5 area.
- Observation 4
Supplies blocking first-pass airflow
OBSERVATION 4 Personnel placed equipment/supplies in an area that blocked the movement of first pass airflow within the LAF hood, either before or after it was filled with sterile product. Specifically, your firm's pharmacy manager failed to place supplies to maintain first pass airflow within LAF Hood during aseptic processing. For example, during the aseptic processing of the sterile drug product, EPI-Shugarcaine Su/F Ophth 1 ml/vial, empty/filled vials and Lidocaine 4% Pres-Free 4.5 mls ampules were arranged in a manner that caused a disruption in first pass airflow within the ISO 5 LAF hood.
- Observation 5
Inadequate HEPA filter coverage/recertification
OBSERVATION 5 The facility design was observed to allow the influx of poor quality air from entering into the ISO 7 Cleanroom/high quality air area. Specifically, your firm failed to have adequate HEPA filter coverage to prevent poor air quality from entering into the ISO 7 Cleanroom. For example, your facility is designed with (15)(4) [illegible] classified radio-pharmaceutical inspection/packaging areas that do not have adequate HEPA filter coverage to ensure poor air quality does not enter into the ISO 7 Cleanroom. Additionally, your firm failed to include the (b)(4) recertification to verify air quality.
- Observation 6
Inappropriate cleaning agents used
OBSERVATION 6 Disinfecting agents and cleaning pads or wipes used are not appropriate for use in the ISO 5 LAF hood designated for the production of sterile drug product. Specifically, your firm is using the non-sterile cleaning product, (b)(4), in the LAF Hood designated for the production of sterile drug product.
- Observation 7
Media fills not worst-case representative
OBSERVATION 7 Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, your firm's procedure, Media Fill Challenge, Document #6.36, uses a (15)(4) [illegible]. (15)(4) Your firm's PIC reported the manipulations and complexity performed using the kit is representative of those performed during radio-pharmaceutical drug processing. The same kit components were modified to simulate non-radio-pharma aseptic transfers that uses a (6)(4-1) manipulation into syringes. The simulated media fill failed to be representative of non-radio-pharma aseptic processing worst-case activities and conditions.
- Observation 8
Batch records lack second verifier
OBSERVATION 8 The batch production and control records are deficient in that they do not include identification of persons performing and checking each significant step in the operation. Specifically, your firm's production worksheets failed to include a second verifier for critical steps in your pharmacy's production process. For example, in selected production batch records, I found only your firm's pharmacist (the only firm employee) who reviewed and approved the production batch/lot. Your pharmacy failed to have a second person to verify defined critical steps within the production process that affect finished drug product identity, strength, quality, and purity. (b)(6) A. Rx, Cefuroxime 7.5 mg/ml Ophth Soln 2.5 mls, Expiry 1/18/2019 B. Rx(b)(6), EPI-Shugarcaine Su/F Ophth 1 ml/vial, Expiry [illegible] C. Rx(b)(6), Joint Mix Ropiv/Morph 10 mg, Exp [illegible] D. Rx(b)(6), Joint Mix #2 Bupiv/Mo, HAB 1-0.5-25 per 0.2 ml Lipo, Exp [illegible] E. Rx(b)(6) [illegible]
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3004819860 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3004819860. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.