Skip to content

Isorx Corp

845 Marina Bay Pkwy Ste 9, Richmond, California, United States

FEI 3006624492

FDA has one inspection on file for Isorx Corp in Richmond, California (FEI 3006624492). It ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 4 observations from the PDF; they are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
1, in 2019
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
↗
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Supplies not disinfected before ISO 5

      OBSERVATION 1 Materials or supplies were not disinfected prior to entering the aseptic processing areas. Specifically, On 9/11/2019, you removed a pre-sterilized/depyrogenated syringe from the ISO 5 laminar flow hood and cleanroom, which exposed the syringe to unclassified air in your lab space. You then returned this syringe to your ISO 5 laminar flow hood. This syringe was used in the production of 1-123 Metaiodobenzylguanidine (MIBG) USP, Rx [illegible], lot [illegible] MIBG, a sterile drug product.

    2. Observation 2

      Non-sterile wipes used in ISO 5

      OBSERVATION 2 Disinfecting agents and cleaning wipes used in the ISO 5 classified aseptic processing areas were not sterile. Specifically, On 9/11/2019, you used wipes to clean the interior of your ISO 5 laminar flow hoods that were not labeled as sterile. These wipes are used for your pre-operational cleaning of the laminar flow hood. This ISO 5 laminar flow hood was used to produce 1-123 Metaiodobenzylguanidine (MIBG) Rx [illegible], lot [illegible] MIBG, a sterile drug product.

    Show observations 3 to 4
    1. Observation 3

      No sporicidal contact time required

      OBSERVATION 3 Sporicidal agents were not used in your facility's cleanrooms and/or ISO 5 classified aseptic processing area. Specifically, You do not require a specific contact time for the [illegible] sporicidal that you apply to your ISO 5 laminar flow hoods. This sporicidal was used to clean the laminar flow hood used to produce 1-123 Metaiodobenzylguanidine (MIBG) Rx [illegible], lot [illegible] MIBG, a sterile drug product.

    2. Observation 4

      Incomplete batch production records

      OBSERVATION 4 Batch production and control records are not prepared for each batch of drug product produced and do not include complete information relating to the production and control of each batch. Specifically, You do not maintain production records for the manufacture of drug products. Also your production records do not include a quality verification that the steps of production have been performed correctly. One example includes 1-123 Caps USP, Rx [illegible], lot [illegible], made on 7/9/2019. Examples of omissions on the batch record for this product includes but is not limited to: lack of listing the steps taken to manufacture this product, the identity/amounts of raw materials used in manufacturing, and these records are not signed and dated.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3006624492 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3006624492. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.