Data integrity in FDA Form 483 observations
Records that are incomplete, unprotected or not made at the time: audit trails, deleted or overwritten data, shared logins, uncontrolled forms and backdating. FDAgent finds 120 such observations in 85 Form 483s issued to 84 facilities, for inspections that ended between November 2012 and September 2026. Each is quoted below from the 483 FDA posted.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.
- Observations
- 120
- Each quoted below
- Form 483s
- 85
- Posted by FDA
- Facilities
- 84
- Distinct FEIs
- Most recent
- Sep 3, 2026
- Inspection end date
Observations by year
These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).
Peak: 49 in 2026
| Year | Observations |
|---|---|
| 2012 | 1 |
| 2013 | 0 |
| 2014 | 0 |
| 2015 | 4 |
| 2016 | 8 |
| 2017 | 5 |
| 2018 | 9 |
| 2019 | 4 |
| 2020 | 0 |
| 2021 | 1 |
| 2022 | 7 |
| 2023 | 12 |
| 2024 | 8 |
| 2025 | 12 |
| 2026 | 49 |
How FDAgent sorts observations into this theme
Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.
It is tied to one of these 21 CFR entries
21 CFR 211.68(b)21 CFR 211.18821 CFR 211.194(a)21 CFR 211.186(a)21 CFR 211.18221 CFR 212.60(g)21 CFR 212.110(b)
The same entries the data integrity topic counts. A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.
Or its text contains one of these phrases
“data integrity” · “audit trail*” · “backdat*” · “trial injection*” · “test* into compliance” · “contemporaneous*” · “uncontrolled form*” · “uncontrolled blank form*” · “uncontrolled worksheet*” · “uncontrolled record*” · “uncontrolled document*” · “electronic data” · “electronic raw data” · “shared user*” · “shared account*” · “shared login*” · “shared password*” · “user access” · “access privilege*” · “access level*” · “administrator privilege*” · “administrator right*” · “falsif*” · “delet* … data” · “delet* … result*” · “delet* … chromatogram*” · “overwr* … data”
* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.
The 120 observations, newest first
Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.
Apotek Production & Laboratorier ABInspection ended Jan 29, 2026 · FEI 3003766921 · Observation 4
The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing and processing. Specifically, Batch records do not contain documentation of all interventions performed in the Grade A or the length of time taken to perform each intervention. Routine interventions not recorded include but are not limited to the following: a. Cleaning of b. Adjustment of …
Opens with FDA's citation wording for 21 CFR 211.188(b)Read the Form 483 →
Apotek Production & Laboratorier ABInspection ended Jan 29, 2026 · FEI 3003766921 · Observation 6
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, your firm’s gu Equipment ID ge does not save testing data generated from ag) nor is it attached to any type of system that will print or save the generated raw data. The current process relies on a single analyst to manually transcribe …
Opens with FDA's citation wording for 21 CFR 211.68(b)Read the Form 483 →
Neeyaan LLCInspection ended Jan 27, 2026 · FEI 3024366553 · Observation 1
Laboratory records are deficient in that they do not include a complete record of all data obtained during testing. Specifically, The original raw data from the firm's own testing and Certificate of Analysis (COA) from the third-party testing laboratory that performed the finished product testing for OTC Drug Product (b) (4), USP ((b) (4) Tablet) Lot # (b) (4) could not be identified or provided during the inspection. Your firm personnel provided …
Opens with FDA's citation wording for 21 CFR 211.194(a)(4)Read the Form 483 →
Neeyaan LLCInspection ended Jan 27, 2026 · FEI 3024366553 · Observation 6
… of tablet compression for (b) (4) Lot #(b) (4) revealed a lack of batch records on the production floor to ensure consistent batch manufacturing and contemporaneous documentation of production activities. Upon request of the blending and compression batch records for (b) (4) Lot #(b) (4), the Blending Operator provided incomplete batch records which did not include any batch identification, preventing traceability.
Contains “contemporaneous*”Read the Form 483 →
Neeyaan LLCInspection ended Jan 27, 2026 · FEI 3024366553 · Observation 8
Batch production and control records do not include the specific identification of each batch of component and in-process material used for each batch of drug product produced. Specifically, The batch records for OTC drug product (b) (4), USP ((b) (4) Tablet) Lot #(b) (4) and Lot #(b) (4) do not include the distinctive lot identification of the raw material (active pharmaceutical ingredients and excipients) used in the manufacturing of the drug …
Opens with FDA's citation wording for 21 CFR 211.188(b)(3)Read the Form 483 →
Shimoga ChemicalsInspection ended Jan 23, 2026 · FEI 3033881432 · Observation 1
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that components and raw materials conform to appropriate standards of identity. Specifically, A. Laboratory control procedures are not followed: During review of electronic data for (b)(4) USP API, we observed multiple unreported sample injections prior to or after the official reported sample …
Contains “electronic data”Read the Form 483 →
Shimoga ChemicalsInspection ended Jan 23, 2026 · FEI 3033881432 · Observation 3
Batch production and control records do not include complete information relating to the production and control of each batch. Specifically, A. Your firm fails to maintain accurate and consistent cleaning logs and batch records, demonstrating significant data integrity deficiencies in the documentation of (b)(4) 001 cleaning and (b)(4) of (b)(4) USP API. Review of the following batch (b)(4) batches for (b)(4) reveal discrepancies in cleaning …
Opens with FDA's citation wording for 21 CFR 211.188Read the Form 483 →
Shimoga ChemicalsInspection ended Jan 23, 2026 · FEI 3033881432 · Observation 7
… During the inspection, we observed data integrity deficiencies related to testing of this product, including trial injections and unreported testing of final finished API batches that were shipped to the U.S. market. Without verified methods, your firm cannot ensure that test results are reliable and that only compliant batches are released for distribution.
Contains “data integrity”Read the Form 483 →
Genzyme Ireland LimitedInspection ended Jan 20, 2026 · FEI 3003809840 · Observation 1
Laboratory records are deficient in that they do not include a complete record of all data obtained during testing. Specifically, deficiencies in documentation and data integrity were identified in environmental monitoring and (b) (4) testing records. The records and data for these quality control activities do not demonstrate adequate integrity controls and documentation practices. A) Failing non-viable particulate testing data present in the …
Opens with FDA's citation wording for 21 CFR 211.194(a)(4)Read the Form 483 →
Smithfield Biosciencs, Inc.Inspection ended Dec 23, 2025 · FEI 1527761 · Observation 5
There is an inadequate number of personnel to manufacture and test APIs adequately. Specifically, Your firm is using equipment that does not have audit trail capabilities and unique logins: A.) Your firm currently uses GC-8A by Shimadzu which utilizes printed chromatograms and has no unique logins for analysts. Your firm has purchased a new GC-8860 by Agilent approximately 5 years ago, qualified the GC in April 2023, but have not started …
Contains “audit trail*”Read the Form 483 →
Macau-Union Pharmaceutical LimitedInspection ended Dec 17, 2025 · FEI 3011219786 · Observation 8
Batch production and control records do not include complete labeling control records, including specimens or copies of all labeling used for each batch of drug product produced. Specifically, Your firm did not include specimens or copies of all completed labeling, including the label adhered to packaging bottle and labeling on the (b)(4) packaging carton, in your batch production the (b)(4) records for packaging finished over-the-counter human …
Opens with FDA's citation wording for 21 CFR 211.188(b)(8)Read the Form 483 →
Wizcure Pharmaa Private LimitedInspection ended Dec 10, 2025 · FEI 3030304532 · Observation 1
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards Specifically, Microbiologists responsible for performing sterility testing and collecting environmental monitoring, personnel monitoring, and (b)(4) samples confirmed they do not collect, test, and incubate all samples. A. During inspection of the (b)(4) Biological incubators …
Opens with FDA's citation wording for 21 CFR 211.194(a)Read the Form 483 →
Huons Co., LtdInspection ended Nov 21, 2025 · FEI 3007163376 · Observation 1
Laboratory records do not include complete data derived from all tests, examinations, and assay necessary to assure compliance with established specifications and standards. Specifically, A. During review of the bioburden and endotoxin tests performed on 11/03/2025 for the (b)(4) Line media fill (b)(4) samples, we found the following. a) The (b)(4) Tank and Tank Transfer Line samples endotoxin out of specification (OOS) results obtained on …
Opens with FDA's citation wording for 21 CFR 211.194(a)Read the Form 483 →
Huons Co., LtdInspection ended Nov 21, 2025 · FEI 3007163376 · Observation 5
Batch production and control records do not include complete information relating to the production and control of each batch. Electronic records are used, but they do not meet audit trail requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records. Specifically, Your Audit Trail Review procedure and practice is inadequate. The checklist currently utilized for (b)(4) audit trail reviews do not specifically …
Opens with FDA's citation wording for 21 CFR 211.188Read the Form 483 →
HEC Pharm Co. Ltd.Inspection ended Nov 21, 2025 · FEI 3006259537 · Observation 2
… used for method validation and release testing since August 2025, the MassLynx software used for data analysis and processing has not been qualified to ensure data integrity and compliance.
Contains “data integrity”Read the Form 483 →
Donor Services Laboratories Inc - TampaInspection ended Sep 12, 2025 · FEI 3027286748 · Observation 1
… This practice does not ensure accurate and contemporaneous recording of incubation stop times.
Contains “contemporaneous*”Read the Form 483 →
AGC Biologics, Inc.Inspection ended Apr 18, 2025 · FEI 3000209996 · Observation 1
… associate (analyst) who performs the [illegible] testing method for final bulk drug substance, demonstrated (with typical system access rights) the ability to delete original electronic data from the [illegible] used for test method, among others). There is no routine system-level review to ensure the veracity of electronic data files submitted. c) On 8 Jun 2016, instrument for in-process monitoring of [illegible] and in Building [illegible] were …
Contains “delet* … data”Read the Form 483 →
Guangxi Yulin Pharmaceutical Group Co. Ltd.Inspection ended Mar 21, 2025 · FEI 1000589993 · Observation 2
… e) Your firm lacks controls to ensure data integrity is implemented and maintained over analytical instruments and corresponding analytical software. For example: • There is no audit trail feature for the IRSolution software used in infrared (IR) spectroscopy. • There is no audit trail feature for the UVProbe software used in UV-Vis spectroscopy. Both analytical software systems are used for the component identification tests of the (b) (4) …
Contains “data integrity”Read the Form 483 →
Bioclinica Inc. / Clario (eResearch Technology, Inc.)Inspection ended Feb 27, 2025 · FEI 3032745961 · Observation 1
Transfer of obligations to a contract research organization. Specifically, 1. Your firm failed to validate computer systems used to process, manage, and report electronic data from clinical investigations to ensure accuracy, reliability, and consistent intended performance. For example: A) Your firm used unvalidated software applications (b)(4) and to analyze clinical study bone mineral density data despite your June 2023 COTS assessments …
Contains “electronic data”Read the Form 483 →
Zhejiang Huahai Pharmaceutical Co., Ltd.Inspection ended Jan 24, 2025 · FEI 3003999190 · Observation 3
… There has been no review of the electronic data to see what values were used during US market batches and to evaluate whether these values would have appropriately rejected non conforming tablets. b. Acceptable ranges for compression machine parameters that the operators can change have not been established. For example: feeder speed, fill depth, or target main compression force.
Contains “electronic data”Read the Form 483 →
21 CFR sections these observations open with
The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.
- 21 CFR 211.188Batch production and control recordsIn this theme's rule17
- 21 CFR 211.194Laboratory recordsIn this theme's rule14
- 21 CFR 211.68Automatic, mechanical, and electronic equipmentIn this theme's rule12
- 21 CFR 211.22Responsibilities of quality control unit9
- 21 CFR 211.100Written procedures; deviations3
- 21 CFR 211.113Control of microbiological contamination3
- 21 CFR 211.160General requirements3
- 21 CFR 211.192Production record review2
- 21 CFR 312.62Investigator recordkeeping and record retention2
- 21 CFR 211.101Charge-in of components1
Ask FDAgent about data integrity in Form 483s
FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.
Related
About this data
- The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
- Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
- A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
- FDAgent is independent of FDA.