Skip to content

Bioclinica Inc. / Clario (eResearch Technology, Inc.) Form 483, February 2025

FDA issued this Form 483 to Bioclinica Inc. / Clario (eResearch Technology, Inc.) in Shanghai, China (FEI 3032745961) at the end of a drug inspection that ended February 27, 2025. It lists 1 observation. FDA classified the inspection No Action Indicated (NAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Oct 22, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Feb 27, 2025
Drugs · Bioresearch Monitoring
FDA's outcome
NAI
No Action Indicated
Posted by FDA
Oct 22, 2026
602 days after the inspection
Facility
FEI 3032745961
Shanghai, China

The 1 observation on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Unvalidated systems and data integrity failures

    Transfer of obligations to a contract research organization. Specifically, 1. Your firm failed to validate computer systems used to process, manage, and report electronic data from clinical investigations to ensure accuracy, reliability, and consistent intended performance. For example: A) Your firm used unvalidated software applications (b)(4) and to analyze clinical study bone mineral density data despite your June 2023 COTS assessments acknowledging Part 11 requirements. Critical data integrity gaps existed, as edits/modifications, reassessments, and deletions could be made in these systems with no audit trail before transfer to (b)(4) B) Your validation approach failed to address critical upstream data processing activities, creating risk to data reliability. The absence of validation for these systems resulted in inability to generate complete audit trails, identify users making changes, document reasons for changes, prevent unauthorized modifications, and produce accurate and complete copies of records throughout the entire data lifecycle. 2. Your firm failed to establish and follow adequate procedures to ensure the integrity, accuracy, and reliability of clinical trial data for study (b)(4) Specifically, your firm did not implement effective validation controls, or adequate corrective and preventive actions. For Example: A) Quality Event DEV-06296 documents that correction factors were not properly applied to data in the final data transfer on June 26, 2024, affecting 31 subjects. "There was an IQC correction in prior transfer. In the Final/End of Study transfer, the prior IQC corrections were overwritten with the new data, instead of appended to the prior corrections which is our standard process (IM-SS-W027)." B) Quality Event DEV-06317 documents that hip data for three specific cases (b)(4) were improperly excluded from the data transfer file, despite being required for analysis.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3032745961, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.