Skip to content

eResearch Technology Inc. (dba Clario)

11th Floor, No. 3 Dongye Road, Shanghai, China

FEI 3032745961

FDA has one inspection on file for eResearch Technology Inc. (dba Clario) in Shanghai, China (FEI 3032745961). It ended on and was classified NAI, no action indicated.

NAI means FDA found no objectionable conditions or practices, or found none that justified further action.

FDA posted the Form 483 from that inspection. FDAgent read its one observation from the PDF; it is listed below. Three FOIA requests have asked FDA for this inspection's records.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
NAI
Inspections on file
1, in 2025
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
↗
2 posted
Requested under FOIA
3 requests, latest Mar 25, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringPosted 483 · 1 observation

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Unvalidated systems and data integrity failures

      Transfer of obligations to a contract research organization. Specifically, 1. Your firm failed to validate computer systems used to process, manage, and report electronic data from clinical investigations to ensure accuracy, reliability, and consistent intended performance. For example: A) Your firm used unvalidated software applications (b)(4) and to analyze clinical study bone mineral density data despite your June 2023 COTS assessments acknowledging Part 11 requirements. Critical data integrity gaps existed, as edits/modifications, reassessments, and deletions could be made in these systems with no audit trail before transfer to (b)(4) B) Your validation approach failed to address critical upstream data processing activities, creating risk to data reliability. The absence of validation for these systems resulted in inability to generate complete audit trails, identify users making changes, document reasons for changes, prevent unauthorized modifications, and produce accurate and complete copies of records throughout the entire data lifecycle. 2. Your firm failed to establish and follow adequate procedures to ensure the integrity, accuracy, and reliability of clinical trial data for study (b)(4) Specifically, your firm did not implement effective validation controls, or adequate corrective and preventive actions. For Example: A) Quality Event DEV-06296 documents that correction factors were not properly applied to data in the final data transfer on June 26, 2024, affecting 31 subjects. "There was an IQC correction in prior transfer. In the Final/End of Study transfer, the prior IQC corrections were overwritten with the new data, instead of appended to the prior corrections which is our standard process (IM-SS-W027)." B) Quality Event DEV-06317 documents that hip data for three specific cases (b)(4) were improperly excluded from the data transfer file, despite being required for analysis.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Three requests to FDA under the Freedom of Information Act named this site, most recently on Mar 25, 2026.

  • Inspection ending Feb 27, 2025NAI

    3 requests. In the inspection history above. FDA has posted its Form 483.

    1. Mar 25, 2026FDA-FOIA-2026-2950Inspection recordsRecords released
    2. Sep 3, 2025FDA-FOIA-2025-10524Form 483Records released
    3. Jun 21, 2025FDA-FOIA-2025-7920Form 483· 1 of 10 sitesWithdrawn

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3032745961 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3032745961. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.