HEC Pharm Co. Ltd. Form 483, November 2025
FDA issued this Form 483 to HEC Pharm Co. Ltd. in Yidu, China (FEI 3006259537) at the end of a drug inspection that ended November 21, 2025. It lists 5 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Oct 20, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Nov 21, 2025
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Oct 20, 2026
- 333 days after the inspection
The 5 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Impurity analytical method inadequately validated
Analytical method used for determination of impurities in API is inadequately validated. Specifically, the impurity method used for determination or quantification of impurities in (b)(4) Active Pharmaceutical Ingredient (API) did not detect the presence of an unknown impurity (b)(4) was initiated for assay OOT for (b)(4) in the test sample solution. On 02/20/2025, OOT (b)(4) During the investigation, an unknown peak was detected in (b)(4) batch # (b)(4) the assay chromatogram, which had not been detected in the impurity test chromatogram.
- 2
UHPLC-MS software not qualified
Laboratory instruments are inadequately qualified for their intended use. Specifically, the Ultra High Performance Liquid Chromatography-Mass Spectrometer (UHPLC-MS) used for determination (b)(4) impurities in (b)(4) API has not been fully qualified for its intended use. Although, the installation, operation and performance qualification of the instrument was performed in July 2025 and the instrument has been used for method validation and release testing since August 2025, the MassLynx software used for data analysis and processing has not been qualified to ensure data integrity and compliance.
- 3
Culture media growth promotion not performed
The culture media (b)(4) used for microbial enumeration and environmental monitoring is not validated or adequately validated to determine its capability to support the growth of specific microorganisms. Specifically, growth promotion testing was not performed on the culture media used for surface microbial water was used for monitoring in the laboratories. In addition, (b)(4) used to evaluate foreign microorganism in the (b)(4) growth promotion test performed on the (b)(4) in-process testing (IPC) room within the (b)(4).
- 4
Manufacturing equipment leakage uncorrected
Manufacturing equipment are not maintained to prevent malfunctions. Specifically, on 11/17/2025 continuous leakage of liquid material was observed from the (b)(4) used during the (b)(4) step for (b)(4). Although the leakage was attributed to high operating, no corrective actions were taken to address the issue.
- 5
DCS software failure caused product loss
Manufacturing computer and or related system is not adequately qualified for their intended use. Specifically, the distributed control system (DCS) software used to automate and monitor the operation the (b)(4) production process system did not detect that a valve was open during manufacturing, which led to partial product loss for (b)(4) batch # (b)(4).
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.