Skip to content

HEC Pharm Co., Ltd.

62 Binjiang Road, Yidu, China

FEI 3006259537DUNS 554543994

FDA has 5 inspections on file for HEC Pharm Co., Ltd. in Yidu, China (FEI 3006259537), from 2009 to 2025. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below.

1 import refusal is filed under this FEI, on . No warning letter or court action is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, through Dec 31, 2027. Its registrant is HEC PHARM CO., LTD. (D-U-N-S 554543994).

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
5, 2009–2025
0 OAI · 2 VAI · 3 NAI
Inspections with 483 observations shown
1 of 5
Form 483s posted by FDA
↗
Warning letters
None on file
Import refusals
1 refusal
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Impurity analytical method inadequately validated

      Analytical method used for determination of impurities in API is inadequately validated. Specifically, the impurity method used for determination or quantification of impurities in (b)(4) Active Pharmaceutical Ingredient (API) did not detect the presence of an unknown impurity (b)(4) was initiated for assay OOT for (b)(4) in the test sample solution. On 02/20/2025, OOT (b)(4) During the investigation, an unknown peak was detected in (b)(4) batch # (b)(4) the assay chromatogram, which had not been detected in the impurity test chromatogram.

    2. Observation 2

      UHPLC-MS software not qualified

      Laboratory instruments are inadequately qualified for their intended use. Specifically, the Ultra High Performance Liquid Chromatography-Mass Spectrometer (UHPLC-MS) used for determination (b)(4) impurities in (b)(4) API has not been fully qualified for its intended use. Although, the installation, operation and performance qualification of the instrument was performed in July 2025 and the instrument has been used for method validation and release testing since August 2025, the MassLynx software used for data analysis and processing has not been qualified to ensure data integrity and compliance.

    Show observations 3 to 5
    1. Observation 3

      Culture media growth promotion not performed

      The culture media (b)(4) used for microbial enumeration and environmental monitoring is not validated or adequately validated to determine its capability to support the growth of specific microorganisms. Specifically, growth promotion testing was not performed on the culture media used for surface microbial water was used for monitoring in the laboratories. In addition, (b)(4) used to evaluate foreign microorganism in the (b)(4) growth promotion test performed on the (b)(4) in-process testing (IPC) room within the (b)(4).

    2. Observation 4

      Manufacturing equipment leakage uncorrected

      Manufacturing equipment are not maintained to prevent malfunctions. Specifically, on 11/17/2025 continuous leakage of liquid material was observed from the (b)(4) used during the (b)(4) step for (b)(4). Although the leakage was attributed to high operating, no corrective actions were taken to address the issue.

    3. Observation 5

      DCS software failure caused product loss

      Manufacturing computer and or related system is not adequately qualified for their intended use. Specifically, the distributed control system (DCS) software used to automate and monitor the operation the (b)(4) production process system did not detect that a valve was open during manufacturing, which led to partial product loss for (b)(4) batch # (b)(4).

  2. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  3. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  4. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3006259537, one row per refused product line.

1 refusal on 2017-03-15 · charged NOT LISTED on 1 · no FDA sample analysis

FDA firm profile
  • 2017-03-15

    CLARITHROMYCIN (ANTI-BACTERIAL PART I) (NOT ANTIBIOTIC)61FIS56

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    San Juan District Office508-0365309-1/1/1

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing
Registration runs through
Dec 31, 2027
Registrant
HEC PHARM CO., LTD.D-U-N-S 554543994

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3006259537 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3006259537. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.