Donor Services Laboratories Inc - Tampa Form 483, September 2025
FDA issued this Form 483 to Donor Services Laboratories Inc - Tampa in Tampa, Florida (FEI 3027286748) at the end of a biologics inspection that ended September 12, 2025. It lists 3 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jul 15, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Sep 12, 2025
- Biologics · Human Cellular, Tissue, and Gene Therapies
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Jul 15, 2026
- 306 days after the inspection
The 3 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Records not maintained concurrently with performance
Records were not maintained concurrently with the performance of each step. Specifically, incubation times for the (b) (4) are not concurrently documented. On 9/9/2025, technologist (b) (6), (b) (7)(C) was observed recording the incubation stop time (b) (4) the (b) (4) of incubation. When questioned, the technologist stated that the time recorded represented the (b) (4) rather than the (b) (4) the plate (b) (4) from the incubator. A second technologist, (b) (6), (b) (7)(C) confirmed that they were trained to document (b) (4) (b) (4). This practice does not ensure accurate and contemporaneous recording of incubation stop times.
- 2
Quality program lacks HCT/P deviation investigations
The quality program does not include the investigation and the documentation of HCT/P deviations relating to core CTGP requirements. Specifically, approximately 21 failed test runs from June 2024 to present were reviewed and 18 appeared to be lacking details specific to the investigation, outcome, and actions taken. For example: a) (b) (4) Failed Run Report dated 4/5/2025 documents that the cause of fail is (b) (4) (b) (4) b) (b) (4) Failed Run Report dated 2/3/2025 documents that the cause of fail is (b) (4) (b) (4). c) (b) (4) Failed Run Report dated 6/14/2024 documents that the cause of fail is (b) (4). d) (b) (4) Failed Run Report dated 6/19/2024 documents that the cause of fail is (b) (4). Additionally, your firm was not able to provide failed test run investigations from June 2023 to May 2024.
- 3
Incomplete records missing performer and details
Records did not identify the person performing the work and were not detailed as necessary to provide a complete history of work performed. Specifically, your batch checklist forms of various test records were missing information. For example: a) (b) (4), dated 9/1/2024, did not contain the plate reading time and time out and time in information for the test kit. b) (b) (4), dated 9/1/2024, did not contain the batch number, initial and date of the technologist performing the work, and time out and time in for the test kit. c) (b) (4), dated 9/1/2024, did not contain the technologist who performed the (b) (4) and time out and time in for the test kit. d) (b) (4), dated 9/9/2025, did not contain the stop time after incubating the samples. e) (b) (4), dated 2/14/2025, did not contain the time the (b) (4) was added. f) (b) (4) dated 2/14/2025, did not contain the time in information for the test kit. g) (b) (4) dated 2/14/2025, did not contain the time the (b) (4) (b) (4) was added. Additionally, when we reviewed the read time print out, no time zone is indicated. The (b) (4) (b) (4) explained that the read time print outs use (b) (4) and not (b) (4) (b) (4). For example, the read out for Batch (b) (4) displayed a printed on date of (b) (4).
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.