FDA has one inspection on file for Donor Services Laboratories Inc Tampa in Tampa, Florida (FEI 3027286748). It ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below. One FOIA request has asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 1, in 2025
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 1 request, latest Nov 12, 2025
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene TherapiesPosted 483 · 3 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Records not maintained concurrently with performance
Records were not maintained concurrently with the performance of each step. Specifically, incubation times for the (b) (4) are not concurrently documented. On 9/9/2025, technologist (b) (6), (b) (7)(C) was observed recording the incubation stop time (b) (4) the (b) (4) of incubation. When questioned, the technologist stated that the time recorded represented the (b) (4) rather than the (b) (4) the plate (b) (4) from the incubator. A second technologist, (b) (6), (b) (7)(C) confirmed that they were trained to document (b) (4) (b) (4). This practice does not ensure accurate and contemporaneous recording of incubation stop times.
- Observation 2
Quality program lacks HCT/P deviation investigations
The quality program does not include the investigation and the documentation of HCT/P deviations relating to core CTGP requirements. Specifically, approximately 21 failed test runs from June 2024 to present were reviewed and 18 appeared to be lacking details specific to the investigation, outcome, and actions taken. For example: a) (b) (4) Failed Run Report dated 4/5/2025 documents that the cause of fail is (b) (4) (b) (4) b) (b) (4) Failed Run Report dated 2/3/2025 documents that the cause of fail is (b) (4) (b) (4). c) (b) (4) Failed Run Report dated 6/14/2024 documents that the cause of fail is (b) (4). d) (b) (4) Failed Run Report dated 6/19/2024 documents that the cause of fail is (b) (4). Additionally, your firm was not able to provide failed test run investigations from June 2023 to May 2024.
Show observation 3
- Observation 3
Incomplete records missing performer and details
Records did not identify the person performing the work and were not detailed as necessary to provide a complete history of work performed. Specifically, your batch checklist forms of various test records were missing information. For example: a) (b) (4), dated 9/1/2024, did not contain the plate reading time and time out and time in information for the test kit. b) (b) (4), dated 9/1/2024, did not contain the batch number, initial and date of the technologist performing the work, and time out and time in for the test kit. c) (b) (4), dated 9/1/2024, did not contain the technologist who performed the (b) (4) and time out and time in for the test kit. d) (b) (4), dated 9/9/2025, did not contain the stop time after incubating the samples. e) (b) (4), dated 2/14/2025, did not contain the time the (b) (4) was added. f) (b) (4) dated 2/14/2025, did not contain the time in information for the test kit. g) (b) (4) dated 2/14/2025, did not contain the time the (b) (4) (b) (4) was added. Additionally, when we reviewed the read time print out, no time zone is indicated. The (b) (4) (b) (4) explained that the read time print outs use (b) (4) and not (b) (4) (b) (4). For example, the read out for Batch (b) (4) displayed a printed on date of (b) (4).
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Nov 12, 2025. It asked for a Form 483.
Inspection ending Sep 12, 2025VAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Nov 12, 2025FDA-FOIA-2025-12875Form 483· 1 of 5 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3027286748 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3027286748. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.