FDA has 9 inspections on file for Smithfield Bioscience Inc in Cincinnati, Ohio (FEI 1527761), from 2009 to 2025. The latest ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 6 observations from the PDF; they are listed below. Six of the nine FOIA requests for this site have asked FDA for this inspection's 483.

FDA's compliance record also lists one other action under this FEI: Seizure, . No warning letter or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, through Dec 31, 2026. Its registrant is Smithfield Bioscience, Inc. (D-U-N-S 196665368).

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
9, 2009–2025
1 OAI · 5 VAI · 3 NAI
Inspections with 483 observations shown
1 of 9
Form 483s posted by FDA
↗
Requested under FOIA
9 requests, latest FY2023
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

9 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate process validation for critical parameters

      Process Validation performed does not demonstrate that critical process parameters produce consistent APIs meeting their specifications and quality. Specifically, Your firm's process validation for (b) (4) USP, (b) (4) product codes, does not include validation of processing times listed in the batch record and in procedure SOP# 149. For example, (b) (4) (b) (4) (b) (4) cycle minimum times in the batch record were not tested, function was not monitored or recorded, maximum and minimum loads are not defined for stress testing the process, and (b) (4) being held throughout the cycle is not monitored. In addition, your firm manually switches cycle (b) (4) (b) (4) and (b) (4) operation rather than using recipes for repeatability. Your firm processed product code batches and (b) (4) product code batches during process validation due to various significant deviations and OOS results, such as product Color, atypical Loss on Drying, Total Plate Count failures, and other issues. This caused your firm to make additional batches in order to achieve process validation criteria of three consecutive product batches meeting specification. Your firm has released approximately (b) (4) out of (b) (4) out of batches of product code produced in the past two years and [illegible] batches of (b) (4) product code produced in the past two years. In addition, your firm's procedure, SOP# 149, "Operating the (b) (4)" states to (b) (4) Your firm does not document or review (b) (4) (b) (4) to confirm it approaches maximum low. In addition, your firm halts (b) (4) (b) (4) to check for product appearance to be (b) (4) cycles during (b) (4) On 11/04/2025, during (b) (4) USP, lot (b) (4) your firm halted the (b) (4) cycle from approximately 11:00am to 01:59pm to check for product appearance to be (b) (4) Your firm [illegible] until 11/6/2024 at 8:15am. resumed the cycle and continued (b) (4)

    2. Observation 2

      Inadequate supplier qualification and material verification

      Supplier qualification do not include evaluations that provide adequate evidence that the manufacturer can consistently provide material meeting specifications Specifically, A.) Your manufacturer of (b) (4) has stated that "This product is unsuitable for use in the production of APIs as (b) (4) do not follow required GMP practices and do not sell pharmaceutical grade products". You proceeded to qualify this manufacturer of (b) (4) without obtaining a COA listing the identification and quantitation of all impurities as per the USP requirements. Additionally, you did not conduct a risk assessment to determine if this product would affect the quality of the final product. B.) Your firm has not completed additional testing of (b) (4) per USP standards at appropriate intervals since 2021 to assure that the manufacturer can consistently provide (b) (4) meeting specifications. C.) Your supplier of (b) (4) has not provided comprehensive certificates of analysis per USP requirements for every shipment/lot of (b) (4) received since 2021 and your firm has not checked and verified the reliability of certificates of analysis at regular intervals.

    Show observations 3 to 6
    1. Observation 3

      Inadequate review and control of records

      Batch records and laboratory records of critical steps are not reviewed and approved by the quality unit appropriately. Specifically, A.) Your analytical laboratory paper records do not include signature and date of the second person reviewing (b) (4) (b) (4) impurity data on HPLC-1 for batches (b) (4) These batches were later released by QA without investigating whether they were reviewed or not. In addition, your firm does not include an electronic signature of review for HPLC data. B.) Your microbiology laboratory paper records do not include the signature of the second person reviewing the record for accuracy including for growth promotion studies and finished product testing. C.) (b) (4) used in production of (b) (4) USP does not have user login and parameters on the (b) (4) can be changed by anyone with access to the room. Non-production personnel such as engineering, regulatory affairs, and quality assurance can access these controls. In addition, without user login there is no electronic traceability of operators performing manual cycle switches. D.) (b) (4) contain a shared administrator password for all users. This causes there to be no electronic traceability of operators performing manual cycle switches.

    2. Observation 4

      Failure to thoroughly investigate discrepancies and OOS

      ***REPEAT OBSERVATION FROM FDA 2019 INSPECTION*** Failure to conduct thorough investigations into unexplained discrepancies and the failure of a batch to meet any of its specifications. Specifically, A.) Your complaint investigation #137 for an additional doublet peak in the NMR spectra around (b) (4) ppm has not been thoroughly investigated. The identity of this peak has not been identified to date and retrospective analysis of previous NMR results data was not conducted. B.) Your firm failed to positively identify "black specks" that were found in (b) (4) lots (b) (4) Your firm performed FTIR testing on the substance and no peaks were obtained. Your quality unit failed to get a positive identification on the "black specks". (b) (4) (b) (4) and released on 12/16/2025. batches were reprocessed into (b) (4) was rejected. C.) In October 2024, your firm recorded two out-of-specification (OOS) results for Limit of (b) (4) in batches (b) (4) (b) (4) in Batch (b) (4) was retested twice, and the OOS result was confirmed on both occasions. Batch (b) (4) was retested six times, with the OOS result confirmed in each retest. As the OOS results were confirmed for both batches, they were deemed unsuitable for release, and Quality Assurance determined that the batches required reprocessing. This decision included batch (b) (4) which was being reprocessed during the week of 12/15/2025 into (b) (4) Your firm did not identify a root cause for the OOS results associated with these batches.

    3. Observation 5

      Inadequate personnel and noncompliant laboratory equipment

      There is an inadequate number of personnel to manufacture and test APIs adequately. Specifically, Your firm is using equipment that does not have audit trail capabilities and unique logins: A.) Your firm currently uses GC-8A by Shimadzu which utilizes printed chromatograms and has no unique logins for analysts. Your firm has purchased a new GC-8860 by Agilent approximately 5 years ago, qualified the GC in April 2023, but have not started utilizing the new equipment due to resources being limited with turnover of key quality personnel. B.) Your firm is utilizing a UV-Vis that is not capable of audit trail review or unique logins for analysts. Your firm qualified a new UV-Vis in January 2025, however, you have not started testing with this equipment due to validation needing performed. Your firm's Regulatory Affairs and Laboratory Managers stated that this was also delayed due to turnover of key quality personnel.

    4. Observation 6

      Stability program not followed annually

      The stability program to justify assigned expiration or retest dates is not followed. Specifically, Your firm has not placed any (b) (4) USP (b) (4) batches on stability in 2024 or 2025. In accordance with your approved stability procedure SOP 021 Stability Testing of Bulk Drug Substances, Rev. S, Effective Date 12/22/2020, at least one batch per year is required to be put on stability. In 2024, (b) (4) USP (b) (4) batches, were released and in 2025 batches of (b) (4) USP, (b) (4) were released.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  7. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  8. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  9. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Nine requests to FDA under the Freedom of Information Act named this site, most recently on FY2023.

  • Inspection ending Dec 23, 2025OAI

    6 requests. In the inspection history above. FDA has posted its Form 483.

    1. Jun 15, 2026FDA-FOIA-2026-5814Form 483Records released
    2. Apr 6, 2026FDA-FOIA-2026-3390Form 483 + EIRRecords released
    3. Apr 1, 2026FDA-FOIA-2026-3260Form 483· 1 of 21 sitesClosed over fees
    4. Apr 1, 2026FDA-FOIA-2026-3153Form 483Records released
    5. Mar 31, 2026FDA-FOIA-2026-3092Form 483 + EIRClosed
    6. Feb 6, 2026FDA-FOIA-2026-1271Form 483· 1 of 5 sitesRecords released
  • Inspection ending Jul 15, 2022VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Sep 1, 2022FDA-FOIA-2022-6355Form 483Closed
  • Inspection date not given

    2 requests. None of FDA’s log entries for these requests say records were released.

    1. FY2023FDA-FOIA-2023-3766EIRClosed
    2. FY2023FDA-FOIA-2023-3003Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing
Registration runs through
Dec 31, 2026
Registrant
Smithfield Bioscience, Inc.D-U-N-S 196665368

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 1527761 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 1527761. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.