Skip to content

SCA Pharmaceuticals Inc

8821 Knoedl Ct, Little Rock, Arkansas, United States

FEI 3010683157

FDA has 5 inspections on file for SCA Pharmaceuticals Inc in Little Rock, Arkansas (FEI 3010683157), from 2014 to 2025. The latest ended on and was classified OAI, official action indicated. FDA has issued 2 warning letters under this FEI, the latest on (CDER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDA published 4 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

No court action or import refusal is filed under this FEI.

Six regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
5, 2014–2025
3 OAI · 2 VAI · 0 NAI
Inspections with 483 observations shown
5 of 5
2 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
5 posted
Warning letters
· CDER ↗
2 on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Air Supply

      Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.

    2. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.

    3. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

    4. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that drug product containers conform to appropriate standards of identity, strength, quality and purity.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    2. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    3. Air Supply

      Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.

    4. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its cleaning and maintenance.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate sterility testing

      Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing. Specifically, your method allows for [(o) (4) with the (o) (4) for sterility testing which is not equivalent to USP <71>.

    2. Observation 2

      Failure to review potency failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, on April 5, 2019, you were notified of a confirmed potency failure for Vasopressin 0.4 units/ml in 0.9% NaCl [illegible] bag at the 50-day timepoint for beyond use dating (BUD) by your contract testing laboratory. You assigned a 90-day BUD until May 7, 2019 when you changed the BUD to 50 days. You did not notify your customers of the change in date for (o) ( ) lots of product you distributed prior to changing the BUD due to sub potency results. In addition, your complaint procedure does not specifically include directions when a reserve/retain sample will be tested or visually inspected as part of the complaint investigation as evidenced by CUS 19-020-LR, CUS 19-058-LR, CUS 10-059-LR, CUS 19-060-LR, CUS 19-069-LR, CUS 19-079-LR, and CUS 19-094-LR.

    Show observations 3 to 6
    1. Observation 3

      Insufficient computer/audit controls

      Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, you have never conducted an audit trail review of the SCANRDI system since you began using it in 2013 for sterility analysis nor do you have a procedure for conducting an audit trail review. Additionally, an employee who performs most of the scanning for the sterility analysis signs in with her Administrator access to perform the scans.

    2. Observation 4

      Missing packaged product documentation

      The results of the examination of the packaged and labeled products were not documented in the batch production or control records. Specifically, I observed during the visual inspection by employees rejects from the 100% and the AQL were placed in the same bin, thus not allowing for accurate data to be entered in the batch records to determine if both passed your specification for visual inspection as defined in SOP COM-013-LR. For the AQL, critical defect limit is (b)(4) so if both rejects were counted as part of the 100% inspection, the lot would pass instead of failing.

    3. Observation 5

      Compounding copies of approved drugs

      You compound drugs that are essentially a copy of one or more approved drugs within the meaning of sections 503B(a)(5) and 503B(d)(2). Specifically, you compound drug products that: a) are identical or nearly identical to an approved drug that is not on the drug shortage list in effect under section 506E at the time of compounding, distribution, and dispensing; or b) are not identical or nearly identical to an approved drug but contain a bulk drug substance that is also a component of an approved drug, and for which there is no change that produces for an individual patient a clinical difference, as determined by the prescribing practitioner, between the compounded drug and the comparable approved drug.

    4. Observation 6

      Inadequate sterility training/recertification

      Employees engaged in the processing of a drug product lack the training required to perform their assigned functions. Specifically, employees responsible for the sterility analysis by Scan RDI are two months late in their [illegible] recertification and continue to process sterility analysis using Scan RDI.

  4. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  5. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance6 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    2. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process.

    3. Equipment to control conditions

      Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.

    4. FDCA 503B(a)(10)

      Drug product label, outsourcer facility

      The labels of your outsourcing facility's drug products are deficient.

    5. Clothing appropriate for duties performed

      Clothing of personnel engaged in the processing of drug products is not appropriate for the duties they perform.

    Show 1 more citation
    1. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

  6. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  7. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.

    2. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions.

    3. Sanitation--buildings not clean, free of infestation

      Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.

    4. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    5. Clothing appropriate for duties performed

      Clothing of personnel engaged in the manufacturing and processing of drug products is not appropriate for the duties they perform.

    Show 2 more citations
    1. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

    2. Equipment to control conditions

      Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.

Regulations FDA cited here

The 8 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 5 inspections, with how many of them cited each.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3010683157 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3010683157. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.