SCA Pharmaceuticals, LLC Form 483, April 2014

FDA issued this Form 483 to SCA Pharmaceuticals, LLC in Little Rock, Arkansas (FEI 3010683157) at the end of a drug inspection that ended April 2, 2014. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Apr 2, 2014
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Jan 17, 2024
3,577 days after the inspection
Facility
FEI 3010683157
Little Rock, Arkansas

FDA's 7 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Testing and release for distribution

    Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.

  2. Cleaning System

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions.

  3. Sanitation--buildings not clean, free of infestation

    Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.

  4. Investigations of discrepancies, failures

    There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

  5. Clothing appropriate for duties performed

    Clothing of personnel engaged in the manufacturing and processing of drug products is not appropriate for the duties they perform.

  6. Validation lacking for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

  7. Equipment to control conditions

    Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

  • Warning LetterJun 25, 2015CDER · 449 days after this inspection ended

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3010683157, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.